StyleView™: SV22
Replacement Battery
www.ergotron.com
Assembly Instructions
A
1
1x
1
10mm
Back View
a
Turn off all mounted
equipment.
b
Disconnect Power System
from power source.
c
Turn power system off by holding
down the standby button on the
RUI for 1 - 3 seconds.
Power light will shut off.
dRemove front cover
and disconnect RUI
cables from jacks
located on side of
outlet box.
WARNING: Only Ergotron-specified batteries
may be used in the StyleView Power System.
Please call customer care for details.
Do not replace the batteries while cart is
located in an oxygen rich or hazardous
environment.Sparking may occur.
USA 1-800-888-8458
Europe +31 (0)33-45 45 600

888-83-018-00 rev.A • 05/ 06
2 of 6
10mm
2Remove battery
cover.
10mm
Unplug cord reel for better access.
3Remove protective boots,
terminal bolts and cables.
a
b
c
def
Remove Black (negative) lead before
removing Red (positive) lead. Be careful
not to contact tools between terminals
on battery and metal chassis.
1/8"

3 of 6
888-83-018-00 rev.A • 05/ 06
BATTERY MUST
BE RECYCLED
LEAD
4
R
emove old battery.
5
Place new battery in tray and install new battery.
ab
ab
Old Battery
New Battery

888-83-018-00 rev.A • 05/ 06
4 of 6
Reconnect cables with
terminal bolts and replace
protective boots.
7Replace battery cover,plugging the cord reel back in if unplugged, and tighten screws.
Verify proper
polarity when
attaching cables.
Failure to do so will
result in blown fuse
on battery harness.
a
b
cd
6
ab
10mm
10mm
Connect Red (positive) lead before
connecting Black (negative) lead.Be
careful not to contact tools between
terminals on battery and metal chassis.
1/8"

5 of 6
888-83-018-00 rev.A • 05/ 06
b
Turn power system on by holding down the
RUI Standby button for 1 - 3 seconds. The
Power light, the battery charge indicator lights
and the alarm enabled light will come on. See
page 6 for more details on RUI functions.
8Initial Battery Charge
9Ongoing Battery Charges
Back View
cPlug power cord into appropriate wall outlet.
aMake sure RUI cables are
connected.
dVerify that the light is flashing
to indicate battery is charging.Con-
tinue to charge until light stops flash-
ing and stays lit.
Charge battery as often as possible! With power system on,plug the power cord into an appropriate wall
outlet.Plugging in the power cord for short periods of time DOES NOT affect the battery's ability to take a full
charge,and prolongs battery life.
NOTE:Batteries may not achieve optimal performance until the 5t h discharge / recharge cycle.
• Warranty on fully charged* batteries left in an unused state for more than three (3) consecutive months is
automatically void.
• Warranty on fully discharged** batteries left in an unused state for more than three (3) consecutive days
is automatically void. In order to avoid losing power to your equipment,Ergotron recommends that you
charge the battery as often as possible and,if the system is not going to be used for 3 months or more,
remove the battery.
*Fully charged:Battery charge will be at 100% and all RUI indicator lights will be illuminated.
**Fully discharged: Battery charge will be at 0% and all RUI indicator lights will be off.
CAUTION: The supplied
Cord is rated for hospital
use.Connecting the Cord
to an outlet that is not
hospital-grade (indicated
with green dot) will
not ensure grounding
protection.

888-83-018-00 rev.A • 05/ 06
6 of 6 Contains electrical
components.For
information on disposal
Contact Customer Service:
© 2006 Ergotron, Inc.
All rights reserved.
While Ergotron, Inc. makes every effort to provide accurate and complete information on the installation and use of its products, it will not be held liable for any editorial
errors or omissions (including those made in the process of translation from English to another language), or for incidental,special or consequential damages of any nature
resulting from furnishing this instruction and performance of equipment in connection with this instruction.Ergotron,Inc.reserves the right to make changes in the product
design and/or product documentation without notification to its users. For t he most current product information, or to know if this document is available in languages ot her
than those herein, please contact Ergotron Customer Care at: 800-888-8458 or consult the Ergotron, Inc. website at: ww w.ergotron.com. No part of this publication may be
reproduced, stored in a retrieval system , or t ransmitt ed in any form or by any means, elect ronic, mechan ical, photocopying, recording or otherwise without the prior w ritten
consent of Ergotron,Inc.,1181 Trapp Road, Eagan,Minnesota,55121,USA
Patents Pending and Pat ented U.S. & Foreign. Ergotron is a registered trademark of Ergotron, Inc.
For Warranty information in other languages
contact customer service. USA 1-800-888-8458
Europe +31 (0)33-45 45 600
Table of contents
Other Ergotron Lifting System manuals
Popular Lifting System manuals by other brands

Aquatec
Aquatec orca operating instructions

Dannmar
Dannmar D-12 Series user manual

Simon, Evers & Co
Simon, Evers & Co K 658791 operating manual

REID LIFTING
REID LIFTING porta-gantry 500 Assembly & operation manual

morse
morse 40 Operator's manual

B-TEC
B-TEC Carry Twin 3.5 Installation, operating instructions and parts list

Sealey
Sealey MC450.V2 instructions

Harsh
Harsh HS10T Operator's manual

WPG
WPG MT1010TDC operating instructions

twin busch
twin busch TW M-02 Installation, operation and maintanance

Tuxedo
Tuxedo JMC9KAC-TUX Installation & operation manual

Tractel
Tractel Blocfor Installation, operating and maintenance manual