INSTRUCTION SHEET
WARNINGS:
1. These products shall be used only as illustrated and recommended in product instruction sheets (additional instruction sheets are available at www.erico.com)
. Misuse or misapplication may cause failure resulting in possible
property damage or bodily injury.
2. These products must be used only in the manner depicted in the illustrations that accompany them and must not exceed load ratings.
3. Failure to observe these specifications may cause product malfunction resulting in property damage or bodily injury. ERICO products at the time of shipment are warranted to conform to any applicable written description
furnished to the Buyer by ERICO, and to be free from defects in material and workmanship. NO OTHER WARRANTY, WHETHER EXPRESSED OR IMPLIED, (INCLUDING ANY WARRANTY OF MERCHANTABILITY
OR FITNESS), SHALL EXIST IN CONNECTION WITH THE SALE OR USE OF ANY ERICO PRODUCT.
4. All instructions must be completelyfollowed to ensure proper and safe operation.
5. All pipe supports, hangers, intermediate components and structural attachments must ONLY be used as described herein and are NEVER to be used for any other purpose.
The buyer and/or installer is responsible for:
a. Application in conformance to all governing codes.
b. The integrity of structures to which the products are attached, including their capability of safely accepting the loads imposed, as evaluated by a qualified engineer.
c. Using appropriate industry standard hardware as noted above.
SAFETY WARNING:
SAFETY INSTRUCTIONS: All governing codes and regulations and those required by the job site must be observed. Always use appropriate safety equipment such as eye protection, hard hat, and gloves as appropriate to the
application.
CADDY, CADWELD, CRITEC, ERICO, ERIFLEX, ERITECH and LENTON are registered trademarks of ERICO International Corporation
TECHNICAL SUPPORT: cfs358_a.doc 1of 22005 ERICO, INC.
www.erico.com
SFCLTCF
Required for 2’x2’ lighting fixtures (luminaries) in a
2’x4’ T-bar grid in addition to SFCLT clamps.
The SFCLTCF is designed to maintain the main runner/cross runner
connection of the suspended ceiling system (T-bar). When installing a
2’X2’ light fixturein a 2’X4’ T-bar grid, or an AC louver in a 2’X4’ T-bar
grid, or light fixtures parallel to the main runners, the load must
transfer to the supporting main runner through the cross runner. It is
essential to install each SFCLTCF using the 2 #10 self-tapping
screws provided in the package. The SFCLTCF can also be used to
support box type fixtures.
Note: Prior to installation of any SFCLT, check to make sure:
·The T-Bar grid is anchored properly.
·All cross runners are securely attached to the main runners.
·Main runners have No. 12 gauge wire hangers at 4' spacing.
·All wire hangers are properly tied with at least 3 turns.
U.S. Patent Nos.
5,941,029 and 6,029,414
If the existing T-Bar support system does not have No. 12 gauge wire hangers spaced 4' apart, attach two independent
No. 12 gauge wires to two SFCLT clamps at opposite corners of the fixture. Holes are provided in the topof the SFCLT clamps for this
purpose.
If the main runner connection (joint) is located between the two T-Bar hanger wires that are adjacent to the light fixture being secured
with SFCLT clamps, a SFCLTCFS is required to re-enforce the main runner joint. The SFCLTCFS is a straight connector for joining
two main runners.