esera automation 11319 User manual

Art No 11319
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 1 of 9
User Guide
1-Wire Controller 1 Ethernet
1-Wire Controller for autonomous
communication and updating of the 1-Wire
network
Fast readout of all 1-Wire devices in the
1-2 seconds cycle
Cyclic output of the prepared 1-Wire data in
plain text
Operation without additional driver
Data logging in case of communication
interruption to the control system//host system
(optional)
Power supply for 1-Wire Network
Designed for small up to large 1-Wire Networks
Top-hat rail housing for control cabinet
installation
Wide supply voltage range
Management of all ESERA-Automation
and many standard 1-Wire modules
1 Introduction
Before you start assembling the 1-Wire Controller 1 and before you take the device into operation, please read
these assembly and operating instructions carefully to the end, especially the section referring to the safety notes.
2 Product description
Independent management
The 1-Wire Controller is designed for the independent management of a 1-Wire network. You no longer have to
worry about the 1-Wire commands or formulas in order to evaluate sensor data. The controller independently scans
the 1-Wire network for components (sensors and actuators) and will, depending on the found component, provide
the respective data output, readily converted in plain text.
Formatted data output
The 1-Wire Controller ensures the cyclical output of readily processed sensor and actuator data, for instance for
temperature sensors in C°. Only a division by 100 is necessary.
Additionally, the article number for ESERA-Modules can be supplied, the calculation and the output occur adjusted
to the function of the module.
Designed for all 1-Wire Networks
The 1-Wire interface of the controller is specially designed to safely handle 1 Wire networks, from small ones up to
very large ones, with long cable sections. 1-Wire sensors can simultaneously be operated, miscellaneously, in
parasitic or normal mode. The currently most powerful 1 Wire interface was used, in order to ensure maximal data
safety for complex network structures as well.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 2 of 9
System time / real time clock
You do not have a real-time clock with battery buffering in your system? No problem, the 1-Wire Controller 1 will
gladly provide the time with date. The real-time clock (RTC) is supplied by a maintenance-free Gold cap (super
capacitor) for approx. 2 days in case of power failure.
What is a Goldcap (super capacitor)? You can find an explanation here:
https://de.wikipedia.org/wiki/Superkondensator.
Power supply
In order to supply power, the 1-Wire Controller has a wide range input of 9 - 30VDC and is thus equally suitable
for 12V power supplies and for typical industrial 24VDC power supplies.
You can find appropriate DIN rail or plug-in power supplies in our webshop.
Commissioning
How to Videos for commissioning and configuration can be found on our website www.esera.de under
Service and Support, Support Videos.
Note: Basic information and tips on the 1-Wire Bus System can be found in the ESERA Online Shop at
1-Wire basics or please refer to our eBook in the shop under Training/Documentation
3 Auto-E-Connect® Support
The ESERA Auto-E-Connect® 1-Wire Plug and Play system will be used for the
1-Wire Bus supported. This enables fully automatic configurations of 1-Wire sensors
and actuators on the 1-Wire bus. It is optimized for industrial applications and
enables significant added value beyond the sensor and chip data.
The Auto-E-Connect function automatically recognizes ESERA chips, sensors and actuators, starts suitable
libraries and outputs fully formatted data.
The Auto-E-Connect functionality will be available from mid-2020 via 1-Wire Controllers, 1-Wire Gateways and
1-Wire ECO from ESERA available.
Further information on ESERA Auto-E-Connect can be found on the ESERA website, ESERA Config-Tool 3, or in
the download area for this article in the ESERA Webshop.
4 Technical data
Ethernet Interface: TCP/IP oder UDP
- 10/100 MBit Ethernet Interface (RJ45)
- Auto Negotiation (Full-duplex and Half-duplex)
- Auto MDI/MDIX
- Support for DHCP or fix IP-Adress
Firmware Update/
Configuration: ESERA Config Tool III
Power supply: 9-30VDC
Power consumption: maximally 500 mA
Power supply RTC: Goldcap, buffering of the internal clock (RTC) for approx. 2 days if the supply voltage
fails. In case of a longer failure the RTC has to be reset.The Coldcap is charged after
approx. 2 hours.
1-Wire interface: 1-Wire Bus (5V, GND and data)
Protective circuits: ESD protection and reverse polarity protection
Connection: Screw terminals (up to 2,5qmm wire cross section)
Output voltage: 5V (+/-10%), maximally 200 mA, overload-proof and short-circuit-proof
Isolation: Galvanic separation between data and 1-Wire interface
Supported DS2401, DS1963, DS1990, DS1820, DS18S20, DS18B20, DS2413, DS2438, DS2450
1-Wire devices: DS2408, DS2405, DS2406 (only input), DS2423, further chips on request.
We are happy to support further devices as OEM product for you.
5 Ambient conditions
Temperature, operation -10°C up to +55°C
Air humidity: 10 - 92% (non-condensing)
Protection system: IP20
Protection class: III
Measurements: 35 x 90 x 70mm (WxHxD)

Art No 11319
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 3 of 9
6 Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, interference immunity
EN 61000-6-3, interference radiation
RoHS
7 LED Indicator
The module has various display LEDs. In the following the function of the displays
Display
Designation
Function
LED Green
PWR
Display for supply voltage
LED Green
DATA
after switching on the device, the LED flashes 3 times
flashes during 1-Wire activity
View when sending data via the data interface
flashes very quickly if "AL Receive" has been activated
and the "CAL messages" of the control system are
missing.
LED Green
Data interface
Network Link LED,
Lights up when a network connection is established
LED Green
Data interface
Network Data LED
Lights up during data communication via the data interface
8 Connection
Modul topside
1-Wire Bus
7 = GND 1-Wire
8 = 1-Wire Data
9 = + 5V Output
Modul buttom side power supply 10-30VDC
1 = Minus supply voltage
2 = Plus supply voltage
Note:
11 = Reset Button

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 4 of 9
9 Connection example 1-Wire Multisensor

Art No 11319
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 5 of 9
10 Connection example 1-Wire Hub III, Sensors and Actuators

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 6 of 9
11 Connection example with iButton reader
12 Software
Data interface ESERA ASCII text
protocol
You configure the Ethernet interface
with the help of the Windows ESERA
program "Config Tool 3". This
program can be found in the
download area of the ESERA online
shop
13 Configuration and
Communication with
1-Wire Controller 1
The 1-Wire Controller 1 has
extensive configuration and
formatting options that can be read
and operated with the ESERA
"Config-Tool 3".
Since the communication between
the 1-Wire controller 1 and the
Config-Tool 3 takes place via the
open ESERA ASCII text protocol, you can also use any terminal program to
(e.g. Hercules or Putty) exchange data with the 1-Wire Controller 1 via UDP / TCPIP and carry out the
configuration
For details on the communication commands, refer to the document "Programming Manual", which can be
found in the download area of the ESERA online shop and within Config-Tool 3.

Art No 11319
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 7 of 9
14 Firmware- Update
The latest device software (firmware) can
be found in the download area of
Config Tool 3. When commissioning the
1-Wire controller, please check for new
firmware versions. Please use the latest
version.
You update the firmware via
Config Tool 3.
Please refer to the operating instructions
for Config Tool 3, which can be found
within the Config Tool software under the
"HELP/SUPPORT" tab.
You will find a video about the firmware
update on our website under "Service
and Support, Support Videos".
14.1 Recovery function
Firmware- Update
If the update is faulty, for example due to a power failure during the update, you can
use the recovery function. To do this, hold down the reset button (this is located
under hole 11 on the top of the module), start the update in Config Tool 3 and release
the reset button after about 1 second after starting in Config Tool 3. Now the update
should start.
After performing an update, we recommend disconnecting the 1-Wire Controller / 1-
Wire Gateway from the power supply for about 30 seconds and restarting it.
If you have problems with the installation, we will be happy to help you. Simply
contact our support team by e-mail (support@esera.de).
15 Example for the integration into IP-Symcon
On our website, we provide ESERA IP-Symcon software modules for easy
integration of the 1-Wire Controller into IP-Symcon. This provides you with seamless
integration into the software.
Details can be found on the ESERA website under "Compatible controllers / central units / IP-Symcon
integration".
https://www.esera.de/kompatible-steuerungen-zentralen/ip-symcon-integration/
16 Example for the Integration in Loxone
Via the shop we provide an example project for the easy integration of the 1-Wire Controller into the Loxone
Miniserver. With this you extend the Miniserver with many 1-Wire functions.
Details can be found on the ESERA website under "Compatible Controllers / Central Units / Loxone Integration".
https://www.esera.de/kompatible-steuerungen-zentralen/loxone-integration/demo-1-wire-controller-1-loxone-
integration/
17 Example for the Integration in FHEM
For the integration into the open source automation software FHEM we provide a software module for the easy
integration of the 1-Wire controller. This provides you with a very powerful 1-Wire interface in FHEM.
Details can be found on the ESERA website under "Compatible controllers / central units / FHEM integration
https://www.esera.de/kompatible-steuerungen-zentralen/fhem-integration/
18 Example for the Integration in KNX Automation
For integration into a KNX automation system, we offer a software module for the Gira Homeserver together with
the Grot company. This provides you with a very powerful 1-Wire integration for your KNX system. Details can be
found on the ESERA website under "Compatible controllers / control centres / KNX Gira Homeserver
https://www.esera.de/cat/index/sCategory/339

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 8 of 9
19 Your software not included?
The 1-Wire Controller 1 can be integrated extremely universally into many devices and software solutions due to
the text protocol used.
20 Operating conditions
The operation of the assembly group can take place only on condition of observing the required voltage and the
ambient conditions. The operating position of the device is irrelevant. The device is meant to be used in dry or
humid areas.
Should condensed water build up within the sensor, an acclimatisation period of at least 2 hours must pass.
Assembly groups and components do not belong into the hands of children!
The building group can be operated only under the supervision of an electrically skilled person.
In industrial facilities, the accident prevention regulations of the federation of industrial professional associations for
electrical installations and equipments must be observed.
Do not operate the assembly group in an environment with inflammable gases, vapours or dusts or in an
environment where such gases, vapours or dusts may be found.
21 Assembly
The installation location must be protected against moisture. The device may only be used in dry indoor rooms.
The device is intended for mounting inside a control cabinet as a stationary device.
22 Disposal Note
Do not dispose of this device in the household waste. Electronic devices must be disposed of in
accordance with directives for disposing of waste electrical and electronic equipment at local
collection points for electronic waste material.
23 Safety Instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be observed,
especially VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing. During
installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics for
a part or assembly are, how to connect an external circuit, which external components or additional devices can be
connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.
Kits should be returned without their housing when not functional with an exact error description and the
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or
disassembly of cases charges will be invoiced.
During installation and handling of components which later have mains potential on their parts, the relevant VDE
regulations must be observed.
Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified
electrician and put into operation.
Commissioning may only be realized if the circuit is built into a contact proof housing.
If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be installed
upstream or a suitable power supply can be used.
After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance,
https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.

Art No 11319
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11319 V3.0 R1.0 Manual Page 9 of 9
24 Warranty
ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship defects
and have the contractually assured characteristics. The statutory warranty period of two years begins from date of invoice.
The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for damages, for
example, for non-performance, fault in contracting, breach of contractual obligations, consequential damages, damages for
tort and other legal grounds are excluded. Excepting to this, ESERA GmbH accepts liability for the absence of a guaranteed
quality resulting from intent or gross negligence. Claims made under the Product Liability Act are not affected. If defects occur
for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is faulty, the buyer has the
right to have the original purchase price refunded or a reduction of the purchase price. ESERA GmbH accepts liability neither
for the constant and uninterrupted availability of the ESERA GmbH for technical or electronic errors in the online offer.
We develop our products further and we reserve the right to make changes and improvements to any of the products
described in this documentation without prior notice. If you need documentation or information about older product versions,
25 Trademarks
All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are trademarks,
registered trademarks or other copyright or trademarks or titles or legally protected designations of their respective owners
and are hereby recognized as such by us. The mention of these designations, logos, names and trademarks is made for
identification purposes only and does not represent a claim any kind on the part of ESERA GmbH on these designations,
logos, names and trademarks. Moreover, from their appearance on ESERA GmbH webpages it cannot be concluded that
designations, logos, names and trademarks are free of commercial property rights.
ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH.
1-Wire is a product name of the company. Maxim Integrated Products, Inc., USA. Further information
http://www.maxim-ic.com
26 Contact
ESERA GmbH
Adelindastrasse 20
87600 Kaufbeuren
GERMANY
Tel.: +49 8341 999 80-0
Fax: +49 8341 999 80-10
www.esera.de
WEEE-Number: DE30249510
Other manuals for 11319
1
Table of contents
Other esera automation Controllers manuals

esera automation
esera automation ECO 10 User manual

esera automation
esera automation 11325 User manual

esera automation
esera automation 11320 User manual

esera automation
esera automation 11319 User manual

esera automation
esera automation ECO 208 PRO User manual

esera automation
esera automation Auto-E-Connect 11340 User manual

esera automation
esera automation 1-Wire Controller 1 User manual