User Guide
ESERA Extender 3
Distribution Module / Patch field
for 1-Wire Bus system
Performance characteristics
Distributor for 1-Wire Network
7 terminals (push-in) for network cable
1 modular socket for cabling with CAT network
cable
Patch field for star topology,
Star-shaped cabling (connected in parallel)
Housing for DIN rail mounting
Typical fields of application
Central 1-Wire Network distributor
Sub-distributor for 1-Wire Network
Laboratory equipment, scientific equipment
1 Introduction
Before you start assembling the 1-Wire Extender 3 and putting the device into operation, read these operating
instructions carefully until the end, especially the section referring to safety instructions.
2 Product description
We call the product a 1-Wire Extender or distribution module. However, the terms patch panel, extender, data
distributor or terminal board are also used.
The 1-Wire Extender 3 is intended as a distributor for 1-Wire networks. The 7 push-in terminals mean that no
tools are required for connection. The 1-Wire Extender 3 greatly accelerates and extremely simplifies the
installation and cabling of 1-Wire networks. The 1-Wire Extender 3 can be used, for example, as a central
distributor after a bus coupler / controller or 1-Wire Hub.
Equipped with an 8-pole modular socket, several 1-Wire Extensions 3 can be elegantly connected by CAT
network cable can be connected via a 1-Wire Extension 2 distributor.
The 1-Wire Extension 3 is ideally suited for sub-distribution boards or floor distributors in combination with DIN rail
modules.
The various 1-Wire extenders form a coordinated cabling system.
For coupling to control systems, we recommend the use of an ESERA 1-Wire Controller. This simplifies the
software connection enormously due to the many automatic functions.
No software is required for this module.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11142 V2.0 R1.0 Manual Page 2 of 4
3 Technical data
Input/Output: 1 x RJ45 sockets connected in parallel (12VDC, 5VDC, GND and Data)
Input/Output: 7 x push-in terminals (12VDC, 5VDC, GND and Data)
Operating voltage: 12VDC and 5VDC
Operating current: RJ45 socket max. 500mA, push-in terminals max. 3A
Protection circuits: Reverse polarity protection for 5V input/output
Temperature, operation: -20°C to +60°C
Humidity: 10 - 92% (non-condensing)
Dimensions: Housing 112x41x 35 (LxWxH)
Protection class: III
Housing protection type: IP00
4 Conformity
EN 50090-2-2
EN 61000-4-2, ESD
EN 61000-4-3, HF
EN 61000-4-4, Burst
EN 61000-4-5, Surge
EN 61000-6-1, Interference immunity
EN 61000-6-3, Interference radiation
RoHS
5 Connection plan
Connection, input/output for 1-Wire network
The push-in terminal (X1-X7, screwless terminal) and the RJ45 modular socket (X8) are connected in parallel.
The input signal can be fed to the module at any point.
It is also possible to use the two connectors (X1-X7 and X8) as adapters from network cable to single cable.

Art. No. 11142
All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11142 V2.0 R1.0 Manual Page 3 of 4
6 Assignment RJ45 socket
1 GND
2 +5VDC
3 GND
4 1-Wire Data
5 GND
6 unoccupied
7 +12VDC
8 GND
7 Push-In socket (input/output)
The Push In terminal and the RJ45 socket are connected in parallel, which means that both connections can be
used equally.
8 1-Wire Network
Basics and tips for the 1-Wire bus system can be found in the ESERA Online Shop at https://www.esera.de/1-
wire-grundlagen/ or please refer to our eBook, available for purchase in the shop under
Training/Documentation (https://www.esera.de/service-support/dokumentation/352/grundlagen-1-wire-
bus-ebook?number=11901)
9 Operating conditions
The device may only be used in dry indoor areas. The module can be operated in any position.
The device is designed for mounting on top-hat rails, such as those used in fuse cabinets.
10 Assembly
The installation site must be protected from moisture. The device may only be used in dry indoor rooms and in
protected outdoor areas.
The device is intended for installation inside a control cabinet as a stationary device.
11 Disposal note
Do not dispose of the device within the household waste!
According to the directive concerning old electrical and electronic appliances,
electronic devices must be disposed of via the collecting points for old electronic
appliances!
12 Safety instructions
When using products that come into contact with electrical voltage, the valid VDE regulations must be observed, especially
VDE 0100, VDE 0550/0551, VDE 0700, VDE 0711 and VDE 0860
All final or wiring work must be carried out with the power turned off.
Before opening the device, always unplug or make sure that the unit is disconnected from the mains.
Components, modules or devices may only be put into service if they are mounted in a contact proof housing.
During installation they must not have power applied.
Tools may only be used on devices, components or assemblies when it is certain that the devices are disconnected
from the power supply and electrical charges stored in the components inside the device have been discharged.
Live cables or wires to which the device or an assembly is connected, must always be tested for insulation faults or
breaks.
If an error is detected in the supply line, the device must be immediately taken out of operation until the faulty cable
has been replaced.
When using components or modules it is absolutely necessary to comply with the requirements set out in the
accompanying description specifications for electrical quantities.
If the available description is not clear to the non-commercial end-user what the applicable electrical characteristics
for a part or assembly are, how to connect an external circuit, which external components or additional devices can
be connected or which values these external components may have, a qualified electrician must be consulted.
It must be examined generally before the commissioning of a device, whether this device or module is basically
suitable for the application in which it is to be used.
In case of doubt, consultation with experts or the manufacturer of the components used is absolutely necessary.
For operational and connection errors outside of our control, we assume no liability of any kind for any resulting
damage.

All rights reserved. Reproduction as well as electronic duplication of this user guide, complete or in part, requires the written consent of
ESERA GmbH. Errors and technical modification subject to change. ESERA GmbH, ESERA-Automation 2020
www.esera.de 11142 V2.0 R1.0 Manual Page 4 of 4
Kits should be returned without their housing when not functional with an exact error description and the
accompanying instructions. Without an error description it is not possible to repair. For time-consuming assembly or
disassembly of cases charges will be invoiced.
During installation and handling of components which later have mains potential on their parts, the relevant VDE
regulations must be observed.
Devices that are to be operated at a voltage greater than 35 VDC / 12mA, may only be connected by a qualified
electrician and put into operation.
Commissioning may only be realized if the circuit is built into a contact proof housing.
If measurements with an open housing are unavoidable, for safety reasons an isolating transformer must be
installed upstream or a suitable power supply can be used.
After installing the required tests according to DGUV / regulation 3 (German statutory accident insurance,
https://en.wikipedia.org/wiki/German_Statutory_Accident_Insurance) must be carried out.
13 Warranty
ESERA GmbH guarantees that the goods sold at the time of transfer of risk to be free from material and workmanship
defects and have the contractually assured characteristics. The statutory warranty period of two years begins from date of
invoice. The warranty does not extend to the normal operational wear and normal wear and tear. Customer claims for
damages, for example, for non-performance, fault in contracting, breach of secondary contractual obligations,
consequential damages, damages resulting from unauthorized usage and other legal grounds are excluded. Excepting to
this, ESERA GmbH accepts liability for the absence of a guaranteed quality resulting from intent or gross negligence.
Claims made under the Product Liability Act are not affected.
If defects occur for which the ESERA GmbH is responsible, and in the case of replacement goods, the replacement is
faulty, the buyer has the right to have the original purchase price refunded or a reduction of the purchase price.
ESERA GmbH accepts liability neither for the constant and uninterrupted availability of the ESERA GmbH or for technical
or electronic errors in the online offer.
We are constantly developing our products further and reserve the right to make changes and improvements to any of the
products described in this documentation without prior notice. Should you require documents or information on older
14 Trademarks
All mentioned designations, logos, names and trademarks (including those which are not explicitly marked) are
trademarks, registered trademarks or other copyright or trademarks or titles or legally protected designations of their
respective owners and are hereby expressly recognized as such by us. The mention of these designations, logos, names
and trademarks is made for identification purposes only and does not represent a claim of any kind on the part of ESERA
GmbH on these designations, logos, names and trademarks. Moreover, from their appearance on ESERA GmbH
webpages it cannot be concluded that designations, logos, names and trademarks are free of commercial property rights.
ESERA and Auto-E-Connect are registered trademarks of ESERA GmbH.
15 Contact
ESERA GmbH
Adelindastrasse 20
87600 Kaufbeuren
GERMANY
Tel.: +49 8341 999 80-0
Fax: +49 8341 999 80-10
www.esera.de
WEEE-Number: DE30249510
Table of contents
Popular Home Automation manuals by other brands

Merkury Innovations
Merkury Innovations SMART WI-FI PLUG Start guide

Kogan
Kogan SMARTERHOME KASPUSBAC1A user guide

ZyXEL Communications
ZyXEL Communications Aurora quick start guide

GILBARCO VEEDER-ROOT
GILBARCO VEEDER-ROOT PA0261 installation manual

Andersen
Andersen ROYAL SHOPPER STEEL Instructions for use

Smartenit
Smartenit Harmony G2 Product guide