Essence Care@Home PERS Instruction manual

Care@HomeTM PERS Care@HomeTM PERS
Control Panel Quick User Guide Control Panel Quick User Guide
Portable Emergency Button
Optional Add-on:
Stationary (wall-mounted) Emergency Button
The Care@Home™ PERS Control Panel is the heart of Essence’s Care@Home™ PERS
solution, serving as a standalone Personal Emergency Response System (PERS). The
Control Panel features: an EMERGENCY CALL button, a RESET button, a hands-free
speaker phone, a backup battery, and a PSTN and/or cellular modem. LED indicators
display the system status.
The EMERGENCY CALL button
In case of an emergency, press the EMERGENCY CALL button to trigger a medical alarm
.
A siren sounds and the LED surrounding the EMERGENCY CALL button lights up in Red.
You can cancel the medical alarm by pressing the RESET button (abort time is 0-45
seconds). The Control Panel will attempt to connect to the Monitoring Station and
initiate a voice conversation.
NOTE: You can trigger an Emergency alert by pressing either the Portable
Emergency Button or the Stationary Emergency Button.
The RESET button
The RESET button is used for the following functions:
•Enable/disable the activity timer
•Cancel an active alarm
report in progress
•Clear indicators and
vocal reminders
1
2
1
2
This document and its contents are subject to change without notice
and are the protected intellectual property of Essence SmartCare Ltd. and/or its affiliates.
© 2015 All rights reserved to Essence SmartCare Ltd.
ESUG050029 Rev. 3.7
Indicators
The Control Panel provides the following LED indicators:
Type Symbol Color Display Meaning
Power Green
ON AC power connected
Blinking Battery operation
OFF No power or in sleep mode
Communication
Green
ON Communication available
Blinking Active transmission
Red
ON No SIM-card or PSTN line for
communications
Blinking Blocked transmission
Orange ON An active emergency call
conversation
Trouble Red
ON
CP or peripherals malfunction
or lost communications with
the monitoring station
Blinking Peripheral supervision lost or
low battery power
Activity Timer Blue (ring)
ON Activity timer is ON
Blinking Activity timer expires in less
than 15 minutes
OFF Activity timer is OFF
Emergency Red
ON Message acknowledged
Blinking Unacknowledged alert
OFF Idle
Reset Orange ON (3 Sec) Button pressed
For further information, scan this barcode or go to:
www.essence-grp.com/smart-care/care-at-home-pers
SIM
Battery
Push the ribbed tab at the
bottom of the back cover
Lift the cover off
4Turn the power switch ON.
3Connect the power cord
and close the back cover.
1Open the back cover. 2a Open the back cover.
Insert a SIM-card (cellular model only)
and the backup battery - as illustrated
below.
2b For PSTN Model:
The Control Panel has 2 standard telepho-
ne sockets, located on the rear end - as
illustrated below.
Connect a telephone cable between the
wall socket and the LINE socket.
You may also connect a telephone device
to the PHONE socket.
5After completing this process –
make sure that the Control Panel is
functioning properly, by referring to the
LED indicators (review the indicators
table for reference).
Power Supply and Battery Installation
NOTE: Make sure that the power switch is in OFF status prior to installation.
The Speakerphone
The Control Panel can also be used as a speakerphone. Answering incoming calls is done
by pressing the EMERGENCY CALL button.
The Speakerphone functions like a standard speakerphone, as long as power is provided
by the external power supply. When operating on backup battery, only emergency calls
are allowed.
Adding a Peripheral
Peripherals can be added to the system by the Pairing process.
1. To add a peripheral, press the PAIRING button
(right side of the Control Panel) for 5 seconds.
2. The Control Panel beeps and the ring
around the EMERGENCY CALL button lights up
in Blue, with a circular movement effect.
3. Power-up the peripheral by inserting its batteries.
NOTE: The Portable Emergency Button requires no batteries. Simply press its button
for a few seconds.
•Upon successful pairing the Blue ring flashes twice and the Control Panel beeps.
•Upon unsuccessful pairing the Blue ring changes to Red and flashes twice and the Control
Panel emits a failed beep.
Additional reports sent by the Control Panel:
•Extreme temperature - Upon detection of extreme temperature on the premises -
the report is issued by zone number and the type of extreme temperature (Low or
High)
•Inactivity - Upon Activity Timer expiration or no activity detected following a
predefined period.
•Malfunctions - Upon device or Control Panel malfunction (e.g. low battery, tamper,
power failure, communication problems).
•Missing reminder - Upon a reminder not cleared by the user.
Care@HomeTM PERS Control Panel Quick User Guide

Other Essence Control Panel manuals

Essence CareHome ESUGSC003 User manual

Essence

Essence CareHome ESUGSC003 User manual

Essence Care Home User manual

Essence

Essence Care Home User manual

Essence ESUG05008 User manual

Essence

Essence ESUG05008 User manual

Popular Control Panel manuals by other brands

Nuvico EasyTrack CK-1000 instruction manual

Nuvico

Nuvico EasyTrack CK-1000 instruction manual

Anolis ArcControl 128 user manual

Anolis

Anolis ArcControl 128 user manual

Elektromaten TS 961 Electrical operating instructions

Elektromaten

Elektromaten TS 961 Electrical operating instructions

PowerTech PC170 user manual

PowerTech

PowerTech PC170 user manual

DITEC 99 installation manual

DITEC

DITEC 99 installation manual

RDZ PC-HRX user manual

RDZ

RDZ PC-HRX user manual

Bosch ICP-CC488 user guide

Bosch

Bosch ICP-CC488 user guide

SonicAire COMMAND15 owner's manual

SonicAire

SonicAire COMMAND15 owner's manual

Proteco Q80A instruction manual

Proteco

Proteco Q80A instruction manual

Texecom Premier 412 Premier 816 Premier 832 installation manual

Texecom

Texecom Premier 412 Premier 816 Premier 832 installation manual

Sedna Control Panel user guide

Sedna

Sedna Control Panel user guide

Biamp TEC-X 1000 Installation & operation guide

Biamp

Biamp TEC-X 1000 Installation & operation guide

Satel PERFECTA-IP-32 Installer manual

Satel

Satel PERFECTA-IP-32 Installer manual

Teknim TFP-121 Series Installation & operating manual

Teknim

Teknim TFP-121 Series Installation & operating manual

aguilera AE/SA-C8 installation manual

aguilera

aguilera AE/SA-C8 installation manual

DMP Electronics XR2400F installation guide

DMP Electronics

DMP Electronics XR2400F installation guide

Bticino 352500 manual

Bticino

Bticino 352500 manual

Secutron MODUL-R MR-2200 Programming manual

Secutron

Secutron MODUL-R MR-2200 Programming manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.