910
Under the settingcondition. Then you can press "SET"button to set hot
-air rework station's temperature and the main temperaturearea shines
the setting temperature,you can press UP knob orDOWN knob to adjust
the setting temperature.4s-no-press or press SET knob, youcan keep the
temperature and quitout this setting. (Diagram 6).
A. Setting temperature via handle of rework station. You can press UP knob
or DOWN knob directly to adjust temperature and the main temperature
area indicators setting temperature. 4s-no-press or press SET knob, you
can keep thetemperature and quit out this setting, at that time, you can
adjust hot-air volume by pressing " " Whether screen A orscreen B
shine as you set, the device is under the setting condition and
shining area for switch to screen "A " automatically.
Notice: continually pressing UPor DOWN knob in long time will quickly adjust
the temperature, at that time, the screen don't shine. (Same as belowdescription)
In normal working condition, there are two methods to set hot-air volume:
A. If screen A shines setting temperature through operating the
button of panel. If screen A doesn'tshine you must press the "SET"
button to switch to shine of screen Athen the station under the
setting condition. Then you can press "SET" button to set hot-air rework
station' s temperature and the main temperature area shines the setting
temperature, you can press UP knob or DOWN knob to adjust the setting
temperature. 4s-no-press or press SET knob, you can keep the
temperature and quit out this setting (diagram 7).
B. Setting hot-airvolume via handleof rework station. You can pressUP
knob or DOWN knob to adjust hot-air volume and the main temperature
area indicators setting volume. 4s-no-press or press SET knob, you can
keep the volumeand quit outthis setting, at that time, youcan adjust
hot-air volume by pressing " " When the screen Aor screen Bshine
as you set, the device is under the setting condition and shining
area for switch to screen"A"automatically.
4.Hot-air volume settings
5. Storing the Temperature values
Under normal workingcondition, hold down POWER knob at the left ofpanel,
at the sametime long press(>5s) the UP knob or DOWNor SET toadjust
temperature and air volume to the required values separately in term 1 or
term 2 or term 3. But when you hold down POWER knob at the left of panel and
short press (<5s) UP or DOWN or SET knob to use the storage setting
temperature and airvolume into currentwork temperature and air volume
(diagram8, diagram9, diagram10).
(Notice: up, down, set refer to storage term 1, term 2, term 3)
(diagram 6)
(diagram 7)
(diagram 8) (diagram 9) (diagram 10)
Screen A:
Working state ofshortcut 1
Screen A:
Working state ofshortcut 2
Screen A:
Working state ofshortcut 3
6.Temperature comp temperature and calibration
Under normal working condition, hold down both POWER knob at left of
panel and " " knob on the handle to calibrate. Screen Awill display the
character CAL, and temperature value can be calibrated by pressing UP or
DOWN knobs. Pressingthe SET knobto confirm storage and quit fromthis
calibration (diagram 11).