SWITCHABLE
Temperature readings are available in the Celsius scale or Fahrenheit scale (0C/0F; located in the upper right corner of
LCD.) With the unit o, press and hold the ON/OFF Button for approximately 2 seconds to change the current setting.
DIRECTIONS OF USE
1. Press the ON/OFF Button next to LCD display. A tone will sound as the screen shows
followed by last recorded temperature. After showing the self-test temperature,
the thermometer is now in the testing mode.
2. Position thermometer in desired location (mouth, rectum, or armpit.)
a) Oral Use: Place thermometer under tongue as indicated by «✓» position shown
in Figure 2. Close your mouth and breathe evenly through the nose to prevent
the measurement from being influenced by inhaled/exhaled air.
b) Rectal Use: Lubricate silver probe tip with petroleum jelly for easy insertion.
Gently insert sensor approximately 1cm (less than 1/2") into rectum.
INDICATIONS FOR USE
The digital thermometers are intended to measure the human body temperature in regular mode orally, rectally or under
the arm. And the devices are reusable for clinical or home use on people of all ages, including children under 8 years old
with adult supervision.
contraindications: none
PLEASE READ CAREFULLY BEFORE USING
This digital thermometer provides a quick and highly accurate reading of an individual's body temperature. To better
understand its functions and to provide years of dependable please read all instructions first. This appliance conforms to
the following standards: EN ISO 80601-2-56 Medical electrical equipment – Part 2-56. Particular requirements for basic
safety and essential performance of clinical thermometers for body temperature measurement, EN 60601-1-11 Medical
electrical equipment – Part 1-11. General requirements for basic safety and essential performance – Collateral Standard.
Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment
and complies with the requirements of EN 60601-1-2(EMC), IEC/EN60601-1 (Safety) standards. And the manufacturer
is ISO 13485 certified.
Warnings
Read instructions thoroughly before using digital thermometer.
Choking Hazard: Thermometer cap and battery may be fatal if swallowed.
Do not allow children to use this device without parental supervision.
Do not use thermometer in ear. Designed use is for oral, rectal, and armpit (axilla) readings only.
Do not place thermometer battery near extreme heat as it may explode.
Remove battery from the device when not in operation for a long time.
Consult your doctor for the interpretation of results. Self-diagnosis may lead to the worsening of existing disease
conditions.
Do not attempt measurements when the thermometer is wet as inaccurate readings may result.
Do not bite the thermometer. Doing so may lead to breakage and/or injury.
Do not attempt to disassemble or repair the thermometer. Doing so may result in inaccurate readings.
After each use, disinfect the thermometer especially in case the device is used by more than one person.
Do not force the thermometer into the rectum. Stop insertion and abort the measurement when pain is present.
Failure to do so may lead to injury.
Do not use thermometer orally after being used rectally.
For children who are two years old or younger, please do not use the devices orally.
If the unit has been stored at temperatures over 5°C ~ 40°C (41°F ~ 104°F), leave it in 5°C ~ 40°C (41°F ~ 104°F)
ambient temperature for about 15 minutes before using it.
* The performance of the device may be degraded should one or more of the
following occur:
Operation outside the manufacturer's stated temperature and humidity range.
Storage outside the manufacturer's stated temperature and humidity range.
Mechanical shock (for example, drop).
Degraded sensor.
Patient temperature is below ambient temperature.
* Portable and mobile RF communications can aect the device.
DMT-4132
OWNER’S MANNUAL
SIMPLE
DIGITAL thermometer
CONTENTS
SYMBOL EXPLANATION
PRODUCT ILLUSTRATION
1 Thermometer, 1 Owner’s Manual, 1 Storage Case
Figure 1
LCD ON/OFF Button Battery CapProbe
Direct
Current
Caution
Consult
Accompanying
Documents
Type BF
Applied Part European
Authorized
Representative
Batch
Code Manufacturer
Temperature
Limit
-200C
+550C
General symbol
for recovery/ recyclable
Figure 2
GB
PRECAUTION
Humidity
limitation
15%
95%
Atmospheric
pressure
limitation

CALIBRATION
The thermometer is initially calibrated at the time of manufacture. If the thermometer is used according to the use
instruction, periodic readjustment is not required. However, we recommend checking calibration every two years or
whenever clinical accuracy of the thermometer is in question. Turn on the thermometer and insert into the water bath
and then check the laboratory accuracy of thermometer.
The above recommendations do not supersede the legal requirements. The user must always comply with legal
requirements for the control of the measurement, functionality, and accuracy of the device which are required by the
scope of relevant laws, directives or ordinances where the device is used.
CLEANING AND DISINFECTION
1. Immerse the thermometer probe in distilled water for at least 1 minute;
2. Using a clean, soft cloth to wipe the thermometer down to remove any residue;
3. Repeat step 1 and 2 for three times until no soil is seen with visual inspection after cleaning;
4. For thoroughly clean and disinfection, please use method A or B:
Method A (High level disinfection): immerse the thermometer probe in 0.55% OPA (O-Phthaldehyde),
such as CIDEX OPA, for at least 12 minutes under temperature at 20°C;
Method B (Low level disinfection): Using a clean soft cloth dipped in 70% medical alcohol, wipe the probe
3 times, at least one minute for each time.
5. Repeat step 1 to 3 to remove OPA residuals;
LIMITED WARRANTY
The thermometer is guaranteed for two years from the date of purchase. If the thermometer does not function properly
due to defective components or poor workmanship, we will repair or replace it free of charge. All components are cove-
red by this warranty excluding the battery. The warranty does not cover damages to your thermometer due to improper
handling. To obtain warranty service, an original or copy of the sales receipt from the original retailer is required.
JOYTECH HEALTHCARE CO.LTD.
No.365, Wuzhou Road, Yuhang Economic Development
Zone, Hangzhou city, 311100 Zhejiang, China
Shanghai International Holding Corp. GmbH,
Eiestrasse 80, 20537 Hamburg, Germany
Distributor: FORANS SIA,
“Piepilsētas”, Krustkalni,
Ķekavas nov., LV-2111, Latvija,
tel.: +371 67462367
The product is in compliance with the
requirements of MDD 93/42/EEC, "0197"
is the identification number of notify body.
0197
SPECIFICATIONS
BATTERY REPLACEMENT
1. Replace battery when " " appears in the lower right corner of LCD display.
2. Pull battery cover o as shown in Figure 3.
3. Gently pull out plastic circuit board with battery chamber approximately 1 cm
(slightly less than 1/2") (See Figure 4)
4. Use pointed object such as a pen to remove old battery. Discard battery lawfully.
Replace with new 1.5V DC button type LR41 or SR41, UCC392, or equivalent. Be
sure battery is installed with "+" polarity facing up. (See Figure 5)
5. Slide battery chamber back into place and attach cover.
Figure 3
Figure 4
Figure 5
4. To prolong battery life, press the ON/OFF Button to turn unit o after testing is complete. If no action is taken, the
unit will automatically shut o after around 10 minutes.
*NOTE: Normally the buzzes are “Bi-Bi-Bi- B i-”; Alarm beeps more rapidly when temperature reaches
37,8 0C (100 0F) or higher , and the buzzes are “Bi-Bi-Bi----- Bi-Bi-Bi------ Bi-Bi-Bi”
Note 1: Rectal use is not recommended for home use as OPA will not be readily available outside of a hospital. If
rectal measurement is necessary, we strongly recommend high level disinfection.
Note 2: Please operate according to the manual of OPA for reference.
To prevent damage to the thermometer please note and observe the following: Do not use benzene, paint
thinner, gasoline or other strong solvents to clean the thermometer. Do not attempt to disinfect the sensing
probe (tip) of the thermometer by immersing in alcohol, OPA or in hot water (water over 500C(1220F) for long
time. Do not use ultrasonic washing to clean the thermometer.
Type: Digital Thermometer
Measure Range: 32.0°C ~42.9°C (90.0°F-109.9°F) (°C/°F chosen by
manufacturer)
Accuracy: ±0.1°C (±0.2°F) during 35.5°C ~ 42.0°C (95.9°F ~ 107.6°F)
at 18°C ~ 28°C (64.4°F ~ 82.4°F) ambient operating range ±0.2°C
(±0.4°F) for other measuring and ambient operating range
Operating mode: Direct Mode
Display: Liquid crystal display, 3 1/2 digits
Memory: For storing the last measured value
Battery: One 1.5 V DC button battery (size LR41 or SR41, UCC 392)
Battery life: Approx. 200 hours of continuous operation or 1 year
with 3 measurements per day
Dimension: 13.8 cm x 2.2 cm x 1.2 cm (L x W x H)
Weight: Approx. 12 grams including battery
Expected service life: Three years
Ambient operating range:
Temperature: 5°C ~ 40°C (41°F ~ 104°F)
Relative humidity: 15%~95% RH
Atmospheric Pressure: 700hPa ~ 1060hPa
Storage and transportation condition:
Temperature: -20°C ~ 55°C (-4°F ~ 131°F)
Relative humidity: 15% ~ 95% RH
Atmospheric Pressure: 700 hPa ~ 1060 hPa
Ingress Protection Rating: IP 27
Classification: Type BF
TROUBLESHOOTING
Error message Problem Solution
Temperature taken is
lower than 32.0°C (90.0°F)
Temperature taken is
higher than 42.9°C (109.9°F)
Dead battery: Battery icon is
flashing, can’t be measurable Replace the battery.
The system is not functioning
properly
Turn o, wait one minute and take
a new temperature.
Turn o, wait one minute and take
a new temperature.
Unload the battery, wait for 1 minute and repower it. If the
message reappears, contact the retailer for service.
c) Armpit Use: Wipe armpit dry. Place probe in armpit and keep arm pressed firmly at side.
From a medical viewpoint, this method will always provide inaccurate readings, and should not be used if
precise measurements are required.
3. The degree sign flashes throughout the testing process. When flashing stops an alarm will beep for
approximately 10 seconds. The measured reading will appear on the LCD simultaneously. The minimum
measurement time until the signaling tone must be maintained without exception. The measurement
continues even after the buzzer notification. So that in order to achieve better body temperature measurement
result, recommend to keep the probe in mouth and rectum about 2 minutes, or in armpit about 5 minutes
regardless of the beep sound and at least 30 seconds measurement interval should be maintained.
EVOLU is a registered Trade Mark of FORANS International AG, Switzerland
Table of contents
Other EVOLU Thermometer manuals