Model EWT-3611
Non-Programmable Digital Thermostat
Installer : Save these instructions for future use!
FAILURE TO READ AND FOLLOW INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR
OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY OR PROPERTY DAMAGE.
DESCRIPTION
TECHNICAL BULLETIN
The EWT-3611 is a Non-Programmable Digital Solid State
Thermostat.
Features:
lThe Thermostat shall be powered by 24 vac and with a
AA battery as backup.
lCompatible Equipment: ULTRA-ZONE Control Panels:
ST-2E/3E, NCM-300, BMPlus3000 & UZC-4.
Single Stage Heating and Single Stage Cooling
Equipment. Gas, Electric, Oil or Hydronic.
lLCD continuously displays room temperature.
Temperature set point is displayed when it is being
changed.
lTemperature display can be configured in °F or °C.
lThe Thermostat can be set between 45°F and 95°F.
lBacklit display.
lThe thermostat terminal block has the following
terminals: Y, R, G, W, RC/O, RH/B and C.
lAir Filter Replacement Monitor.
TB-234 090375A0234 Rev. B
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- [email protected] 1
Copyright © 2009 EWC Controls All Rights Reserved
Electrical Ratings
19-30VAC 60 Hz
1.0 Amp (Max load per terminal)
Thermal Ratings
Set point Temperature Range 45°F to 95°F
Operating Ambient Temperature 30°F to 99°F
Storage Temperature Range 14°F to 140°F
ATTENTION
!
This product does not contain mercury. However, this
product may replace a unit which contains mercury.
EWC Controls Inc. would like to advise all technicians
and consumers that all mercury thermostats should
be recycled. You can take your mercury thermostat
to your local HVAC wholesaler for recycling.
Contents:
1 EWT-3611 Thermostat
2 Plastic Wall Anchors
2 #8 x 1” Screws
1 TB-234 Technical Bulletin
Technical Data
Power
Working Environment
Range
Shell
Dimension
Connection Interface
24VAC, 50/60Hz + AA Battery
32°F~120°F
5~95%RH(non-condensing)
Fire Retardant PC ABS
3.5x5.1x1.2 in (HxWxD)
Each terminal is capable of accepting
2 x 18 AWG solid copper wires.
WARNING
!
Do not use circuits exceeding specified voltage. Higher
voltage will damage control and could cause shock or
fire hazard.
Do not short out terminals on gas valve or primary control
to test. Shorted or incorrect wiring will damage thermostat
and could cause personal injury and/or property damage.
Thermostat installation and all components of the system
shall conform to Class 2 circuits per the NEC code.
HEAT
TEMP
SET
fan system
on auto cool off heat
Reset
F
COOL SPAN
FILTER
(Shown with Front Cover Removed) Fig. 1
INSTALLATION
Mount the EWT-3611 Thermostat about 5 feet above the
floor in an area with good air circulation at average
temperature. DO NOT install the thermostat where it can
be affected by:
drafts or dead spots behind doors and in corners
hot or cold air from ducts
radiant heat from sun or appliances
concealed pipes and chimneys
on surfaces such as an outside wall, that are a
different temperature then the room air
temperature.
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- [email protected]
2
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
Copyright © 2009 EWC Controls All Rights Reserved
®
HEAT
TEMP
SET
F
COOLSPAN
FILTER
Mount wallplate and Thermostat
Remove the wallplate from your thermostat by pressing the
release tab on the bottom of the thermostat. See Figure 2.
Figure 2
Position wallplate on the wall and pull the wires through the
large opening. Level the unit for appearance. Mark the
mounting holes for the provided wall anchors.
Drill holes with a 3/16” bit and gently tap anchors into holes
until flush with the wall.
Reposition wallplate to wall, pulling wires through the large
opening. Insert mounting screws provided into the wall
anchors and tighten. See figure 3.
YRG
RC/O
RH/B C
W
Figure 3
In order for this thermostat to control your system, the system type
must be specified by the selector switch on the circuit board inside
the thermostat. There is also a selector switch for your choice of
Fahrenheit or Celsius display. See figure 4.
Fan Mode Selector (HG-HE switch)
The factory position is in the “HG” position. Leave it in this position if
you have a gas furnace or an oil burner. If you have an electric
furnace or hot water coil change the position to “HE”.
System Selector (STANDARD - HEAT PUMP switch)
The factory position for this switch is in the STD position. Leave it in
this position if you have ANY system that uses gas, oil, electric or hot
water heating.
If you have a single stage Heat Pump, the thermostat can be
configured to the Heat Pump mode by moving the switch to the “HP”
position. This thermostat model does not have auxiliary or
emergency heat features, therefore it cannot be used on heat pump
systems that require these functions.
Changing the battery:
One fresh AA alkaline battery should provide about one year of
service. However, when the battery becomes drained, the thermostat
will not function. At your earliest convenience, you need to replace
the battery with one new AA alkaline battery.
NOTE: If you remove or replace the battery, the temperature set point
and Span settings will reset back to the factory default settings.
NOTE: If you plan to be away from the premises over 30 days, we
recommend that you replace the old battery with a new alkaline
battery prior to leaving.
Span Setting
Your thermostat is set at the factory to cycle at 2°F (1°C) above and
below the set temperature. (Span = 2) This setting has been
designed to provide a comfortable room temperature under most
conditions. However, if you find your system cycling too fast or too
slow, the Span can be adjusted to modify the cycle time.
Press and hold BOTH and keys for three seconds.
SPAN will be displayed on the LCD.
Press to raise the Span to 3. This setting increases cycle
time by allowing your system to run longer cycles.
Press to lower the Span to 1. This setting decreases the
cycle time by causing your system to run shorter cycles.
The Span settings remain the same for both HEAT and COOL, and
can be changed in any System Switch position. Any loss of 24vac
and/or battery power will default the Span back to the factory default
setting of 2.
ON DP
1234
HPSTDHEHG
Figure 4
FAHRENHEIT
C
Jumper
The installer should be an experienced and trained
HVAC contractor. Failure to read and follow
instructions carefully before installation or
operation could damage this control or cause
property damage. Test the finished installation for
proper operation.
WIRING
ST-3E
R1
B
R
O
W
G
C
ZONE1
T’STAT
Y
R
G
O/B
W/E
C
ZONE
T’STAT
NCM-300
Gas/Elec. 1H/1C
C
RH/B
Y
G
R
W
RC/O
EWT-3611
C
RH/B
Y
G
R
W
RC/O
EWT-3611
Y
NON-ZONED
GAS OR OIL
1 HEAT/ 1 COOL
NON-ZONED
HYDRO OR OIL
C
RH/B
Y
G
R
W
RC/O
EWT-3611
C
RH/B
R
W
G
C
RC/O
EWT-3611
Y
G
R
W
1 HEAT/ 1 COOL
AIR HANDLER
Y
R
W
C
ZONE2
T’STAT
Y
C
RH/B
Y
G
R
W
RC/O
EWT-3611
COMPRESSOR
Y
G
R
W
Y
C
GAS FURNACE
C
TT
TO
BOILER OR
CIRCULATOR CONTROL
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- [email protected] 3
Copyright © 2009 EWC Controls All Rights Reserved
ISOLATION CIRCUIT
REQUIRED
NO ISOLATION CIRCUIT
REQUIRED
Jumper
NON-ZONED
HEAT PUMP
C
RH/B
Y
G
R
W
RC/O
EWT-3611
R
W
G
C
1 HEAT/ 1 COOL
HEAT
PUMP
Y
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9
R
O
G
C
Y
AIR HANDLER
This thermostat model does not have auxiliary or emergency
heat features, therefore it cannot be used on heat pump
systems that require these functions.
Filter Monitor
Your thermostat also keeps a record of the number of hours
your filter has been in use. To maximize your system
performance and energy efficiency, change or clean your filter
regularly.
When the total fan time reaches 400 hours, you need to clean or
change your system filter, “FILTER” will flash continuously until
the counter is reset to zero.
Press the center button to review filter usage. “FILTER”
displays with the total number usage in hours.
To reset the Filter Monitor counter, press and hold the
center button for 3 seconds when the filter monitor day shows.
OPERATION
Start-up
The LCD will show the factory default display of 70°F (21°C)
when the battery is first installed. The temperature will update
after a few seconds.
System Selector Switch
The System Selector Switch on the front of the
thermostat determines the operating mode of
the thermostat. You may select COOL, OFF or HEAT. NOTE:
Anytime you install or remove the thermostat from the wallplate,
slide the System Selector to the OFF position.
Fan Switch
The Fan Switch should normally be located in the
AUTO position. The fan will be turned on along
with normal operation of your system. In a normal gas or oil
furnace, the fan will be turned on by the furnace after its warm-up
delay. For electric heat, air conditioning, and heat pump operation,
the fan will turn on with the system. To run the fan continuously,
slide the fan switch to the ON position.
Review Current Set-Point Temperature
Press either the up or down key once to see the set-point
temperature. The factory default is 68°F (20°C) with the System
Switch in HEAT, and 78°F (26°C) with the System Switch in
COOL.
Setting New Set-Point Temperature
Press either or once and display the set-point
temperature.
Press either or again to change your desired set-
point temperature. Hold the key down for over 2 seconds to fast
advance the set-point temperature.
Auto Shut Off
Your thermostat will automatically shut off in HEAT mode if the
room temperature rises above 95°F (35°C). It will shut off in COOL
mode if the room temperature drops below 45°F (7°C).
Note that if your system has malfunctioned and no longer
responds to thermostat controls, the Auto shut off will have no
effect.
system
cool off heat
fan
on auto
This thermostat will operate on a full 24vac (R&C) power supply. If
desired, one battery (AA) may be used as a backup power supply
in the event of a power failure. If a full 24vac is not available, then
use one AA battery as the primary power supply.
Backlighting
Your thermostat has an electro-luminescent lamp that backlights
the display for easy viewing in the dark.
When any key is pressed, the display is illuminated.
The display will remain illuminated for 5seconds after the last key
is pressed.
NOTE: If the thermostat is in a Low battery warning condition, the
backlight will not operate. Replace with 1 new AA alkaline battery
to restore the backlight function.
Troubleshooting
PROBLEM SOLUTION
No display Check power to thermostat
or 24vac and/or battery
Dim Display
Fan does not Check HG/HE Switch for correct position
operate properly
Heating or Wait and see if 4 min. time dalay is activated
Cooling does not Check “System Switch” for correct position
operate properly Check Wiring
Thermostat
permanently reads
HI, LO, E1 or E2.
EWC Controls Inc. 385 Highway 33 Englishtown, NJ 07726 800-446-3110 FAX 732-446-5362 E-Mail- [email protected]
4
Copyright © 2009 EWC Controls All Rights Reserved
Thermostat is faulty
Replace Thermostat

Other EWC Controls Thermostat manuals

EWC Controls EWT-955WH User manual

EWC Controls

EWC Controls EWT-955WH User manual

EWC Controls EWT-725 User manual

EWC Controls

EWC Controls EWT-725 User manual

EWC Controls EWT-3900 Ultra-Zone Service manual

EWC Controls

EWC Controls EWT-3900 Ultra-Zone Service manual

EWC Controls EWT-855i User manual

EWC Controls

EWC Controls EWT-855i User manual

EWC Controls EWT-3102 User manual

EWC Controls

EWC Controls EWT-3102 User manual

EWC Controls EWT-3900 Ultra-Zone User manual

EWC Controls

EWC Controls EWT-3900 Ultra-Zone User manual

EWC Controls EWT-3707 Service manual

EWC Controls

EWC Controls EWT-3707 Service manual

EWC Controls EWT-601-2 User manual

EWC Controls

EWC Controls EWT-601-2 User manual

EWC Controls Ultra-Zone IZT-100 User manual

EWC Controls

EWC Controls Ultra-Zone IZT-100 User manual

EWC Controls EWT-955WH User manual

EWC Controls

EWC Controls EWT-955WH User manual

EWC Controls EWT-755WHO User manual

EWC Controls

EWC Controls EWT-755WHO User manual

Popular Thermostat manuals by other brands

Pentair NRG-Temp manual

Pentair

Pentair NRG-Temp manual

Heatmiser DT-ETS WiFi RF manual

Heatmiser

Heatmiser DT-ETS WiFi RF manual

Salus Quantum WQ610 quick start guide

Salus

Salus Quantum WQ610 quick start guide

LEGRAND MyHOME Installer manual

LEGRAND

LEGRAND MyHOME Installer manual

GENERAL LIFE ARUNA 302S RF user manual

GENERAL LIFE

GENERAL LIFE ARUNA 302S RF user manual

Crestron CHV-TSTAT-FCU-HOTEL quick start guide

Crestron

Crestron CHV-TSTAT-FCU-HOTEL quick start guide

Danfoss Devireg 535 Setting up

Danfoss

Danfoss Devireg 535 Setting up

Ecobee 3 smarter wi-fi thermostat user manual

Ecobee

Ecobee 3 smarter wi-fi thermostat user manual

Honeywell RTH7460D1018/E 5-1-1 Quick installation guide

Honeywell

Honeywell RTH7460D1018/E 5-1-1 Quick installation guide

jablotron TP-89 quick start guide

jablotron

jablotron TP-89 quick start guide

HeatRite HT1 Programming guide

HeatRite

HeatRite HT1 Programming guide

Computherm Q7 operating instructions

Computherm

Computherm Q7 operating instructions

Bryant Evolution Connex Control installation instructions

Bryant

Bryant Evolution Connex Control installation instructions

BECA BHT-1000GBLW manual

BECA

BECA BHT-1000GBLW manual

Trane TCONT402AN32DA Installer's guide

Trane

Trane TCONT402AN32DA Installer's guide

Theben RAM 722 operating instructions

Theben

Theben RAM 722 operating instructions

Braeburn Builder 1000NC user guide

Braeburn

Braeburn Builder 1000NC user guide

CAME PSRT01 manual

CAME

CAME PSRT01 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.