Faaborg Rehab Technic charder MS 4900 User manual

0
MS 4900
Medical Scale
USER MANUAL

1
TABLE OF CONTENTS
PREFACE........................................................................................2
GENERAL INFORMATION..............................................................2
SAFETY INSTRUCTION..................................................................2
ENVIROMENTAL.............................................................................3
CLEANING.......................................................................................3
MAINTENANCE...............................................................................3
WEIGHING OPERATION.................................................................3
WARRANTY-LIABILITY...................................................................4
DISPOSING OF THE SCALE .......................................................... 4
SPECIFICATION.............................................................................. 5
PANEL .............................................................................................7
KEY FUNCTION .............................................................................. 8
LCD DISPLAY SYMBOLS................................................................9
USING SCALE...............................................................................10
USING HOLD FUNCTION ............................................................. 11
USING TARE FUNCTION.............................................................. 12
USING BMI FUNCTION................................................................. 12
SETTING-UP MS4900................................................................... 14
PRINT FUNCTION......................................................................... 15
SCALE ASSEMBLING...................................................................17
USING & ASSEMBLING: HEIGHT ROD -HM200M....................... 18
USING & ASSEMBLING: HEIGHT ROD-HM200D/ 201D/ 201M... 19
INSTRUCTION FOR CHARGING AND CONNECTING ................ 20
ASSEMBLY OF TP2100 PRINTER................................................ 21
INSTRUCTION FOR REPLACNG BATTERIES............................. 22
ERROR MESSAGE........................................................................ 23

2
PREFACE
Thank you for choosing Faaborg Rehab Technic’s product. All
features of this product were designed to state of the art and are
optimized for simple and straightforward use. If you have any queries
or experience any problems not addressed in the operating
instructions, please contact your Faaborg Rehab Technic’s service
partner, or visit us on the Internet at www.faaborg-rehab.dk
GENERAL INFORMATION
We strongly recommend you use this device on flat and hard surface.
Any soft surface, like carpet will cause inaccuracy.
SAFETY INSTRUCTION
B efore putting the device into use, please read with care the
information given in the Operating Instructions. They contain
important instructions for installation, proper use and maintenance of
the device.
The manufacturer shall not be liable for damages arising out of
failure to heed the following instructions:
These batteries should be kept away from small children. If swallowed,
promptly seek medical assistance.
When using electrical components under increased safety
requirements, always comply with the appropriate regulations.
Improper installation will render the warranty null and void.
Ensure the voltage marked on the power supply unit matches your
mains power supply.
This device is designed for use indoors.
Observe the permissible ambient temperatures for use
The device meets the requirements for electromagnetic
compatibility. Do not exceed the maximum values specified in the
applicable standards.

3
ENVIROMENTAL
All batteries contain toxic compounds; disposal of batteries
should be delegated to a competent organization, complying with
the deposit of Poisonous Waste Regulation 1972.
Please do not incinerate batteries.
The optimum operating temperature for the scale is 5℃to +35℃;
although it will operate at higher and lower temperatures the
scales battery life will adversely be affected.
CLEANING
We would recommend using alcohol based wipes or similar when
cleaning the scales.
Please do not use large amounts of water when cleaning the
scales as this will cause damage to the scales electronics, you
should also refrain from using corrosive liquids or high pressure
washers.
Always disconnect the scales from the mains power supply
before cleaning.
MAINTENANCE
The scale does not require any routine maintenance. However,
we recommend checking the scale’s accuracy at regular intervals.
The regularity of these checks is dependent on the level of use
and the state of the scale. If any inaccuracies occur, please
contact your local dealer or Faaborg Rehab service partner.
WEIGHING OPERATION
Before reading detailed instructions on how to use all the weighing
functions that are built into your scale, please read the following
important guidelines:
Always be sure that the display shows `Zero` before use, if it does
not then please press the ZERO key.
The device is designed to detect when a stable weight is
achieved, the indicator will `bleep` twice to indicate a stable

4
weight value, your reading should be taken at this point.
WARRANTY-LIABILITY
If a fault or defect is present on receipt of the unit which is within
Faaborg Rehab’s scope of responsibility, Faaborg Rehab shall
have the right to either repair the fault or supply a replacement
unit. Replaced parts shall be the property of Faaborg Rehab.
Should the fault repairs or replacement delivery not be successful,
the statutory provisions shall be valid. The period of warranty
shall be two years, beginning on the date of purchase. Please
retain your receipt as proof of purchase. Should your scale
require servicing, please contact your dealer or Faaborg Rehab
Customer Service.
No responsibility shall be accepted for damage caused through
any of the following reasons: Unsuitable or improper storage or
use, incorrect installation or commissioning by the owner or third
parties, natural wear, changes or modifications, incorrect or
negligent handling, overuse, chemical, electrochemical or
electrical interference or humidity, unless this is attributable to
negligence on the part of Faaborg Rehab.
If operating, climatic or any other influences lead to a major
change in conditions or material quality, the treaty for perfect unit
functioning shall be rendered null and void. If Faaborg Rehab
provides and individual warranty, this means that the unit supplied
will be free of faults for the length of the warranty period.
DISPOSING OF THE SCALE
This product is not to be treated as regular household waste, but
should be handed into an electrical/electronic equipment
recycling center.
You can obtain further details from your local council, your
municipal waste disposal company or the firm which you
purchased the product.

5
SPECIFICATION
Model
MS 4900
Capacity
300kg
300kg
150kg
100g
200g<200kg>500g
100g<100kg>200g
Accuracy
±150g
±200g<200kg>±
500g
±100g<100kg>±
200g
Weight Unit
kg/lb
kg(OIML approved)
LCD Display
1.2 inch LCD display with 5 and 1/2 digits
Dimension
360(L) X 520(W) X 1020(H) mm
Key
Functions
UNIT , PRINT , ON & OFF / ZERO , HOLD/BMI ,
TARE
Power
Supply
6-AA size batteries
9~15V DC adapter
Operation
Temperature
5℃/ 35℃; 0℃/ 40℃(approval)
Standard
Accessories
Screw x 4 , Adaptor x 1 , RS232 cable x 1 , User
manual x 1
Options
Mechanical Height Measurement HM200M
Mechanical Height Measurement HM201M
Digital Height Measurement HM200D
Digital Height Measurement HM201D

6
Standard Accessories
No.
Accessories
Item
Spec.
Qty.
1
Flat head screw
M6 x 20
4
2
9~15V adaptor
1
3
RS232 cable
WR-8159
1
4
User manual
IN-8426
1

7
PANEL
1. Approval Model
2. Non-Approval Model
ON & OFF / ZERO
without lb unit

8
KEY FUNCTION
Key
Description
To change the weighing unit from kg-lb and lb-kg. For
Approval Model this key has been locked at kg unit.
(OIML)
Data transmission via interface(Print-out the results)
Turn ON/OFF the scale.
To reset the display to 0.0kg display / Zero the scale
(±2% of full capacity)
To hold weighing result on the display / long press for
3 seconds to determine Body Mass Index
Tare un-wanted weight.

9
LCD DISPLAY SYMBOLS
Definitions
Stable symbol: To indicate that the weight is stable..
Minor weight: Weight under zero.
Zero symbol: Weight is at zero point.
Low battery: Battery need to charge or replaced.
Stable symbol
Minor weight
value
Zero symbol
Low Battery

10
USING SCALE
WEIGHING
Switch ON the scale using key. The diagnostic scale
self-check is performed and the software version is displayed.
The „0,00 kg” weight displays on the screen, now the scale is
ready for weighing.
Note: If „0,00 kg” wont display on the screen, press key to
zero the scale, can be used any time to zero the scale.
Place a person in the middle of the scale. Wait until the scale
stabilizes and stable sign (ο) shows on the screen.
To turn of MS 4900 long press key for 3 seconds.
Direction:
If a person is heavier than the scale capacity, the display will show
the „Err” prompt (= overload).

11
USING HOLD FUNCTION
MS 4900 is provided with the integrated hold function (determination
of average value). It enables people to be weighed accurately
although they are not still on the scale plate. Once the HOLD key is
pressed, the weight reading will remain on the display after the item
has been removed from the scale so the reading can easily be read.
Note:
Determination of average value is not possible when a person
moves too much.
HOLD function won’t work if the weight is under 2 kg.
Switch ‘ON’ the scale using key. The diagnostic
self-checks is performed. The scale is ready for weighing when
the „0.0 kg” displays on the screen.
Place object/ person in the center of the scale plate.
Press the key. When the triangle is flashing on the
display, the scale records the fluctuating weight values and then
calculates average weight and displays the result on the screen.
Remove the object/ person from the scale platform. The object/
person’s weight reading will remain on the display.
Press the key again to return the scale to the normal
weighing mode.
HOLD key function can be activated before or after putting the
weight on the tread platform. But in case of weighing unstable
person it is recommended to press HOLD key before the person
moves on the tread platform.

12
USING TARE FUNCTION
Tare allows the user to zero the instrument to cancel the weight of a
container/ clothes from the reading of the instrument, thus giving the
true weight of the product/ person being tested.
Place the object need to be tare on the tread platform.
Press TARE key after the weight stabilizes and stable sign
displays.
Place the object need to be weighed (without removing the tare
object)
To delete the saved tare value, remove the tare object from the tread
platform and press [TARE] key.
USING BMI FUNCTION
For BMI calculation, height is needed, therefore it is recommended to
measure the height of subject before starting weighing procedure.
Turn ON the scale using key.
Proceed to weigh as normal.
After the weight is stable and stable sign displays on the
screen long press key.
Display will show the last height value.
Change the height using and key. (Press TARE key
to increase the height and use UNIT to decrease).
OR
If the scale has HM 200D/ HM201D digital height measuring

13
rod simply connect it with MS 4900 and measure the height:
the measurement results will transfer automatically.
Press key to confirm, the Display will show ‘WEIGHT
and BMI’ simultaneously.
Press key again to return to weighing mode.
*Scale will not calculate BMI and weight if weight is unstable
Body Mass Index Categories
Classification of weight for adults over 18 years on the basis of Body
Mass Index according to WHO, 2000 EK IV and WHO 2004 (WHO -
World Health Organization).
Note:
1. Height range: 50-210cm (MS 4900 won’t except height under
50cm and above 210cm)
2. Weight range: over 10kg (For BMI calculation weight must be
10 kg or above).

14
SETTING-UP MS4900
Switch ON the scale and long press [TARE] key for 3 seconds, first
“P 1.1” (software version) and then “A.OFF” will display successively.
AUTO-OFF TIME SETUP
This enables operator to select the auto turn OFF time of the device.
BUZZER ON/OFF SETUP
This enables operator to select beep sound ON/OFF.
Auto off time: 120 sec/180 sec/240 sec/300 sec/off
Range: 2d/ 4d/ 6d/ 8d
Buzzer: On/Off
Note: To confirm the settings, please press ZERO when
displays on the display.

15
PRINT FUNCTION
The Weighing, BMI and Height results can be printed-out for records
using RS232 interface cable (included in accessory kit), which is
connected with the round plug at the back terminal.
After weighing and calculating BMI simply press PRINT key to print
out the results.
The format presented below is the standard format of results
print-out and cannot be changed.
Connecting with PC- MS 4900 both can be connected to PC to
transfer the weighing results.
1. Start Hyper Terminal
Start Hyper Terminal program from clicking
Start Menu → Programs → Accessories → Communication → Hyper
Terminal.
2. New Connection Description
Give new connection a name then click OK.
3. Select Your COM Port
Click Connect to select your COM port. Usually there’s only one

16
option for select. Then click OK.
4. Port Settings
Click Bits per second to set up rate at 9600, Data bits at 8, Parity at
None, Stop bits at 1 and Flow control at Hardware. Then click OK to
complete your setting.
5. Output Data
When the patient has been weighed and BMI calculated, simply
press the PRINT key to output data from scale to PC or an Optional
Printer.
Parameters of RS232 interface
Set parameters of the scale interface on the connected
device. It is not possible to change the scale parameters.
Baud rate: 9600 bps
Parity check: None
Data length: 8 bits
Stop bit: 1 bit
Handshake: RTS/CTS
Data code: ASCII.

17
SCALE ASSEMBLING
1. Assembling column with base.
2. Connecting wire between
column and base first
3. Tightening four screws at the bottom of base.
Assembling is complete.

18
USING & ASSEMBLING: HEIGHT ROD -HM200M
After assembling the HM 200M height rod, simply pull up the height
rod and adjust the head piece according to the person’s height and
key in the height to calculate B.M.I.
1. Fix block on the column and
tight the screws.
2. Fix HM200 M on the
block and tight the screw.

19
USING & ASSEMBLING: HEIGHT ROD-HM200D/
201D/ 201M
After assembling HM 200D/201D with MS4900, connect the height
rod cable with scale indicator. Height will be transmitted from
HM200D/201D to MS4900 when MS4900’s BMI mode is activated.
HM201M is mechanical height rod has same assembly procedure
with HM200D/201D.
1. Fix blocks on the column and
tight the screws.
2. Fix HM200D/201D/201M on
the block and tight the screw.
Table of contents
Other Faaborg Rehab Technic Scale manuals