Rapid Guide Resist SA TAG 10 SA ver.1-1 Rev. A
Resist SA – TAG 10 SA
RESIST TPS SA RESIST PS SA RESIST T SA TAG 10 SA
PRODUCT
RESIST-SA (or TAG10-SA) is an access control device able to archive Codes or Cards, in a completely independent manner. The unit can store n°1
Master Code (code or card) and n° 500 User codes (codes or cards). A Master Code must have at least 6 characters and a maximum of 14 characters,
the user codes must have at least 4 and max. 14 characters. If there is no keyboard, a Passive Cards Kit is needed: this kit contains 12 cards which
simulate the use of the keyboard..
IMPORTANT: The device is provided with activation outputs for valid codes and cards. For this reason, we advise you to install it every time in a
protected position . It is possible to connect to this unit a reader without the decision-making unit (max. distance 100 mt.) which can be used for the
gateway control.
CONNECTIONS ELECTRIC SPECIFICATIONS
• power supply: 12 ÷ 24 Vdc - 12 ÷ 21 Vac
• consumption at 12 Vdc: 180 mA (without outside
Reader or other loads connected)
• consumption at 24 Vdc: 120 mA (without outside
Reader or other loads connected)
• consumption at 12 Vac: 180 mA (without outside
Reader or other loads connected)
• consumption at 21 Vac: 120 mA (without outside
Reader or other loads connected)
• 5 Vdc output for external reader: max 300 mA
(rated voltage 11.5 Vdc)
• 5 Vdc output for external reader: max 60 mA
• Relay-1 and Relay-2 contacts: max 1 A at 24 Vdc
• Buzzer-B output: "open-collector" type without
push-pull diode (max 70 mA at 12 Vdc)
• Alarm exit: "open-collector" type without push-
pull diode (max 70 mA at 12 Vdc)
• inputs Inp-1 and Inp-2: to be activated by
connecting to GND and using a 'clean contact'
(e.g.: a Relay)
NB: the power supply unit for the
management unit is not supplied.
MODE
The following options are available:
• “No-Master-Code” mode; You are in this mode when you activate (or reset) the device with the Master-Code” not yet on. This is the status
when the machine is new or after cleaning (Total or MC only). This condition is marked by 3 led flashing at the same time.
• “Programming” mode; there are various programming modes. You cannot change over from one to the other, but you must always return to the
“Access Control” mode and then select the new programming.. To enable this function, type in a code consisting of two parts separated by the
“X” key. : ”Programming N° ” + “X” + “Master-Code” (or “Programming N°” + “Master-Card”). Such condition is indicated by
activation of the yellow led.
• “Access Control” mode ; You are in this mode when you activate (or reset) the device with the “Master-Code” already on. Openings by
validating the typed codes or cards read are permitted and one can also enter in one of the programming functions. The control unit normally
operates in this way. Such condition is indicated by activation of the red led. When a valid code or card is typed, a green led is activated; when
the typed card/code is not valid, a yellow led is activated for a moment.
+12V
GND
D1-DAT
D0-CLK
BUZZER-B
+5V
ING1
ING2
ALLARME
IN-AC-1
IN-AC-2
RELE1-
A
RELE1-B
RELE2-
A
RELE2-B
LED 5V
RELE’ 1
RELE’ 2
1 2 3 4 5 6
12 ÷ 24 Vdc
12 ÷ 21 Vac
Power supply
Input
1 2 3 4 5 6 7 8 9
M2
M1
Reader B terminal
(with 12Vdc power supply)
J6
J5
Ing-Aux
J1
J6 is for the
"Mem-Exp"
expansion
board (available
as an
accessory)
Open-Collector
Buzzer
To exclude the
buzzer interrupt
the track on
PS2
CPU Board
A
larm output
Door Status
Door opener
Push-button
+5V output
+ G D C B
1 N
2 D
V
Tamper key
Rapid Guide Resist-SA TAG10 SA ver.1-1 rev. A
2
CONFIGURATION MASTER CODE / MASTER CARD
To start the configuration of the different parameters of the unit Resist SA or TAG10 SA, it is necessary to store first on the unit the master code or
the master card.
As the equipment is provided without master code/master card, the first operation necessary to make will be to store the code/card on the device.
Therefore you need to do as follows:
• Verify that the 3 frontal led flash simultaneously.
• Type the code (min. 6 max. 14 characters) than type E, or read the Master card.
• If the operation has been executed in a correct way, only the amber led on the front panel will be activated
IMPORTANT: it is necessary to keep the memorised master code or master card in a safe place as it has to be used to execute all the variations of the
control unit configuration.
PROGRAMMING
The programming of all the parameters of Resist SA or TAG 10 SA can be obtained by choosing one of the eight menus available and by typing the
master code or reading the master card. The following table shows the characteristics of the 8 options that can be programmed
Menù Kind of programming Commands with Master Code Commands with Master Card
1 Inputting new users 1 x Master Code E 1 + reading Master Card
2 Cancelling users 2 x Master Code E 2 + reading Master Card
3 Qualification of users 3 x Master Code E 3 + reading Master Card
4 Import data 4 x Master Code E 4 + reading Master Card
5 Export data 5 x Master Code E 5 + reading Master Card
6 Configuration input/output 6 x Master Code E 6 + reading Master Card
7 Configuration reader B 7 x Master Code E 7 + reading Master Card
8 Activation internal /external card reader 8 x Master Code E 8 + reading Master Card
IMPORTANT: the command enables to enter into the relevant menu, in which you can execute all the operations explained consecutively. It is
important to underline that x means button X while E means typing button E.
To get out of the programming mode, you have to type X for at least 4 seconds.
MENU 1 INPUTTING NEW USERS
To input the users in the control unit archive, you have to indicate for each user, the location number of the memory where the relevant code or card
will be stored. Available numbers are from 1 to 500 and, obviously, they can house a single data-item.
• Enter the function with: 1 x Master Code E or with: -1 then the Master Card reading
• Type in the location No. followed by x, then the user code and then E, or followed by the card reading. For example, if you want to store code
2894 in location 23, the command will be: 23 x 2894 E instead, if you want to store a proximity card in location 37, the command will be:
37 then the Card reading
• Continue like this and input all the necessary codes/cards, then press key E for at least 4 seconds to exit programming, or read the master card.
NB: we advise you to take a note of the number of the locations and the relevant stored users, so that the code or card can be eliminated after card or
right of access has been lost. The user code must have min 4 and max 6 characters. .
MENU 2 CANCELLING USERS
To cancel users from the control unit archive, you must obviously know the memory location number where the relevant code or card was stored. If
you have the card to be cancelled, just read it after entering the mode.
• Enter the function with: 2 x Master Code E or with: 2 then the Master Card reading
• Type in the location No. of the code/card to be cancelled followed by E. If, for example, you wish to cancel the code/card of location 23, the
command will be:23
• Continue like this and cancel all the necessary codes/cards, then press key Efor at least 4 seconds to exit programming, or read the master card.
MENU 3 QUALIFICATION OF USERS
This function enables you to change the access characteristics of a single user or of a group of users. The following can be indicated for every stored
code/card: the activation (output No.) which the control unit must execute, the direction (absent/present), if it is subjected to antipassback
• Enter the function with: 3 x Master Code E or with: 3 then the Master Card reading
• To execute the required modifications, you must first indicate the location number or the range of locations where the codes/cards are stored,
then the command which varies the characteristics. The following table expresses this concept, where NNN or FFF are the location number of
the code/card and Cis the command that changes the parameters.:
Kind of typing Description
NNN x C Displays data of code/card stored at NNN location
NNN x FFF x C Set data for code/card stored from NNN to FFF locations
1111 x C Set data for all code/card stored
• The list of available commands and their meaning is explained in the following table:
CommandC Description Examples
5 Force “Absent” 37 x 5 = User 37 Absent
6 Force “Present” 115 x 6 = User 115 Present
7 Force subjected to “Antipassback” 21 x 7 = User 21 Subjected to Antipassback
8 Force not subjected to “Antipassback” 3 x 8 = User 3 Not subjected to Antipassback
11
10
01
00
For reading on A, both output 1 and output 2 are switched on
For reading on A, only output 1 is switched on
For reading on A, only output 2 is switched on
For reading on A, both output1 and output 2 are switched off
23 x 11 = User 23 switch on both outputs
48 x 10 = User 48 switch on output1
57 x 01 = User 57 switch on output2
21 x 00 = User 21 no switch on anything
1111
….
The command sets the enabling of the outputs, with the same
logic defined for reading on A; (see above box).
63 x 1111 = User 63 enables output 1 and output 2
whether reading is on A or B.
….
0000
The first two digits are the enabling of the outputs for reading on
A, whereas the last two digits are the enabling of the outputs for
reading on B.
25 x 1001 E = User 25 enables output 1 for reading on A
and output 2 for reading on B.
15 x 0001 E = User 15 enables output 2 for reading on B.
MENU 4 IMPORT DATA
This option makes it possible to import to the control unit, all the data which were previously stored on an external memory board (MEM-EXP)
• Enter the function with: 4 x Master Code E or with: 4 then the Master Card reading
• Type in the number which stands for the type of Import to be executed followed by E. These are the possibilities:
1 = Total import 2 = import Codes + Settings 3= import codes only 4 = import Settings only
MENU 5 EXPORT DATA
This option makes it possible to export to an external memory board (MEM-EXP), all the data which were previously stored on the control unit.
• Enter the function with: 5 x Master CodeEor with: 5 then the Master Card reading
• Type in the number which stands for the type of Export to be executed followed by E. These are the possibilities:
1= Total export 2= export Codes + Settings 3= export Codes only 4 = export Settings only
MENU 6 CONFIGURATION INPUT/OUTPUT
With this menu you can set: the function logic of the inputs and the activation times of the control unit outputs.
• Enter the function with: 6 x Master Code E or with: 6 then the Master Card reading
• Type in the command to vary the required parameter. The command consists of two values separated by key x. The first value is the function to
be set, whereas the second value can express: a time or a logic.
Description Command Default Example of typing in
Relay 1 time (in tenths) 1xT (T = time 0 - 65535) 30 1x387 E for time of 38 sec. and 7 tenths.
1x5 E for a time of 5 tenths
Relay 2 time (in tenths) 2xT (T = time 0 - 65535) 30 2x60 E for a time of 60 tenths
Alarm exit Time (in tenths) 3xT (T = time 0 - 65535) 300 3x150 E for a time of 150 tenths
"Door status" disabling time (sec) 4xT (T = time 0 - 65535) 16 4x25 E for a time of 25 seconds
Electric strike management 5x1 = Yes (5x0 =No) 5x1 E activates electric encounter management
Logic INP1 6x1 = NC (6x0 =NO) NO 6x1 E logic NC. “6x0” logic NO
Logic IngP2 7x1 = NC (7x0 =NO) NO 7x1 E logic NC. “7x0” logic NO
Tamper Input Logic 8x1 = NC (8x0 =NO) NC 8x1 E logic NC. “8x0” logic NO
Logic INP-AUX 9x1 = NC (9x0 =NO) NO 9x1 E logic NC. “9x0” logic NO
MENU 7 CONFIGURATION READER B
This configuration makes it possible to program the functions of reader B:
• Enter the function with: 7 x Master Code E or with: 7 then the Master Card reading
• Type in the command to vary the required parameter. The command consists of two values separated by key x. The first value is the function to
be set, whereas the second value can express: a time or an enabling operation.
MENU 8 ACTIVATION INTERNAL/EXTERNAL CARD READER
The above mentioned menu enables you to activate/disable card reader A or B.
• Enter the function with: 8 x Master Code E or with: 8 then the Master Card reading
• Type in the command to vary the required parameter. The command consists of two values separated by key x. The first value is the function to
be set, whereas the second value is the activation/disabling to be executed.
Command Default Description Example of typing in
1x1 = Yes (1x0 = No) Yes Activates RF Module for Passive cards 1x1 E to activate. 1x0 E to disable.
2x1 = Yes (2x0 = No) No Activates card reader B 2x1 E to activate 2x0 E to disable
SPECIAL COMMANDS
65000 × “MASTERCODE E” = All absent 65000 then reading “MASTERCODE E” = All absent
65001 × “MASTERCODE E” = All present 65001 then reading “MASTERCODE E” = All present
65300 × “MASTERCODE E” = Cancel "User Codes" only” 65300 then reading “MASTERCODE E” = Cancel "User Codes" only”
65301 × “MASTERCODE E” = Reset settings only (+ Def.) 65301 then reading “MASTERCODE E” = Reset settings only (+ Def.)
65534 × “MASTERCODE E” = Cancel “Master-Code” only 65534 then reading “MASTERCODE E” = Cancel “Master-Code” only
65535 then reading “MASTERCODE E” = Reset all (and put on Default)
65535 × “MASTERCODE E” = Reset all (and put on Default)
Rapid Guide Resist-SA TAG10 SA ver.1-1 rev. A
3
Description Command Default Example of typing in
Reader B ignore time in seconds 1xT (T = time 0 ÷ 255) 0 1x10 E for a time of 10 sec.
Double gateway 2x1 = Yes (2x0 = No) No 2x1 E to enable “Double gateway”
Management of door associated with B 3x1 = Yes (3x0 = No) No 3x1 E for “Door management” associated with B
Antipassback 4x1 = Yes (4x0 = No) No 4x1 E to activate Antipassback (APB)
No Antipassback at Exit 5x1 = Yes (5x0 = No) Yes 5x0 E on Exit reader, use APB
Reader B Entry 6x1 = Yes (6x0 = No) Yes 6x1 E reader B for Entry and A for Exit
Reset Card 1 7xN (N = Card No.) 0 7x499 E Reset Card 1 is 499
Reset Card 2 8xN (N = Card No.) 0 8x500 E Reset Card 2 is 500
LRC reader B 9x1 = Yes (9x0 = No) Yes 9x0 E disables LRC on reader B
Wiegand/Mag-stripe 10x1 = Wie (10x0 = M-S) M-S 10x1 Ereader B is Wiegand

This manual suits for next models

3

Other FAAC IP Access Controllers manuals

FAAC AT- 4/868 UHF User manual

FAAC

FAAC AT- 4/868 UHF User manual

FAAC MiniTIME SA User manual

FAAC

FAAC MiniTIME SA User manual

Popular IP Access Controllers manuals by other brands

TUYA TC-C1 quick start guide

TUYA

TUYA TC-C1 quick start guide

Panasonic BMET200 - IRIS RECOGNITION operating instructions

Panasonic

Panasonic BMET200 - IRIS RECOGNITION operating instructions

Soyal AR-829E manual

Soyal

Soyal AR-829E manual

ADEMCO MAX Programming instructions

ADEMCO

ADEMCO MAX Programming instructions

Oxgard Praktika K-01 Operational manual

Oxgard

Oxgard Praktika K-01 Operational manual

Fasttel WIZARD ELEGANCE IP instruction manual

Fasttel

Fasttel WIZARD ELEGANCE IP instruction manual

Assa Abloy HID Signo Biometric Reader 25B user guide

Assa Abloy

Assa Abloy HID Signo Biometric Reader 25B user guide

CDVI BIOSYS 1 manual

CDVI

CDVI BIOSYS 1 manual

Sebury Q3 user manual

Sebury

Sebury Q3 user manual

Viking RAD-1A Technical practice

Viking

Viking RAD-1A Technical practice

HID Mercury MR52-S3B Installations and specifications

HID

HID Mercury MR52-S3B Installations and specifications

Iseo Zero1 Libra Smart installation guide

Iseo

Iseo Zero1 Libra Smart installation guide

xpr B100PROX-EH-SA v2 Installer manual

xpr

xpr B100PROX-EH-SA v2 Installer manual

ZKTeco ProBio installation guide

ZKTeco

ZKTeco ProBio installation guide

Sygonix 2299888 operating instructions

Sygonix

Sygonix 2299888 operating instructions

Comunello Automation MAST 50 Installation and user manual

Comunello Automation

Comunello Automation MAST 50 Installation and user manual

FingerTec TA100C user manual

FingerTec

FingerTec TA100C user manual

Soyal AR-721H manual

Soyal

Soyal AR-721H manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.