SAFETY INSTRUCTIONS & WARNINGS
IMPORTANT SAFETY INSTRUCTIONS
•For your safety: carefully read and understand all instructions, this appliance complies with
mandatory safety regulations for electrical equipment. However, improper use will harm
personal and property, please read these instructions carefully, and then open the electrical.
• When using electrical appliances, you must follow basic precautions.
• Do not allow other uses and unattended operation.
• Check that the electrical voltage is correct before use.
• Do not use the air outlet directly against people or animals when using this product.
• The manufacturer can not be liable for damages due to improper use or improper
operation.
• Do not inhale flammable, toxic liquids, such as gasoline, oil, acids or other volatile
substances, to avoid dangerous hazards.
• Only relevant professionals can repair electrical equipment. Improper repairs may result in
considerable risk.
• Do not store the appliance directly at high temperatures such as hot stoves or heat sinks.
• Do not use a cleaning agent or detergent containing solvent.
• This device does not apply to children or those who lack experience with the use of
relevant products unless they have been supervised or instructed to use the equipment to be
responsible for their safety. Children should be supervised to ensure that they do not play
the device.
• Turn off the appliance when cleaning or removing it. Before cleaning or servicing the
appliance, remove the plug from the socket and pull the plug out of the socket.
• Unauthorized parts or third party accessories may be dangerous to make the warranty
invalid.
• Always check whether the float is normal.
• If you notice that the liquid leaks from your equipment, immediately turn it off and unplug
the plug.
• Do not use the appliance in a damp room.
•IPX4 is only granted by connect an IPX4 plug to socket-out of the appliance or the cover of
the socket-out is closed.
•Max. load of socket-out: 1500W.
• Children should be supervised to ensure that they do not play the equipment, only the
equipment stored in children can not access, safe and dry place to store.
• Do not inhale hot dust ashes or sharp objects.
• Do not touch the spectator directly when blowing. When the time to blow the children away.
Wear safety goggles.
• Do not reverse the vacuum cleaner, causing damage to the motor
• The hose can not be overly bent and forced to elongate, otherwise the hose will be
deformed or damaged.
• Do not allow the lid part to penetrate into the water or rinse with water to prevent water from
entering the electronic parts. Leakage, proper operation: gently wipe the surface with a rag

IMPORTANT SAFETY INSTRUCTIONS
This appliance can be used by children aged from 8 years and above and persons with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they have been
given supervision or instruction concerning use of the appliance in a safe way and understand
the hazards involved. Children shall not play with the appliance. Cleaning and user
maintenance shall not be made by children without supervision
If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a
similarly qualified person in order to avoid a hazard.
Correct Disposal of this product This marking indicates that this product
should not be disposed with other household wastes throughout the EU. To
prevent possible harm to the environment or human health from uncontrolled
waste disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and collection
systems or contact the retailer where the product was purchased. They can take
this product for environmental safe recycling.
Technical data
FVC-WD POWERVC 825
240V~, 50/60Hz, 1600W,25L, Max.Load of socket outlet:1500W, Class I, IPX4
Product Parts Name

Standard accessories including
Installation

Caution:Make sure that the power cord plug and socket are de-energized
when assembling the vacuum cleaner
Open the vacuum cleaner you purchased
1. Make sure the power cord is disconnected from the socket(Fig1)
2. Loose Clips(Fig2)
3. Raise the nose assembly from the dust pan. (Fig 3)
4. Remove the internal accessory. (Fig 4)
5. Install the wheels. Align the corresponding holes, pressure down, and install the four
caster on the barrel. (Fig 5)
6. Install the cloth filter in the battel in turn.(Fig.6)
7. Place the top cover assembly on the dust bucket and lock it with both sides of the buckle.
(Fig.7)
8. Align the hose assembly port with the suction port and insert it to the right and tighten it.
(Fig.8)
9. Connect telescopic tube with the hose (Fig 9)
10. The telescopic tube can be adjust to different length (Fig 10)
11. Connect floor nozzle with telescopic tube (Fig 11)
Switch
Press “ ” Start vacuum
Press “ ” Turn off vacuum
Socket
1. Open the power tool socket cover. (Fig.1)
2. Insert the power cord switch and apply pressure to the bottom. (Fig.2)
3.Start the switch. (Fig.3)
WARNING: Before inserting the tool socket, check that the tool you are using is
secure and safe.Max. load of socket-out: 1500W.

Operation of vacuuming dusts
1. Make sure the power cord is disconnected from the socket.(Fig1)
2. Loose Clips.(Fig 2)
3. Raise the Head assembly from the dust tank. (Fig 3)
4. Install the cloth filter in the battel in turn.(Fig.4)
5. Place the nose assembly on a dust bucket, and lock it with both sides of the buckle(Fig5)
6. Align the hose assembly port with the suction port, and then rotate it to the right and insert
it. (Fig 6)
7. Connect telescopic tube with the hose (Fig 7).
8. The telescopic tube can be adjust to different length (Fig 8)
9. Connect floor nozzle with telescopic tube (Fig 9)
10. Start the switch button. (Fig 10)
11. Start the vacuum. (Fig 11)
WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED
‘SAFETY INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE
GASES, VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS
INCLUDE BUT ARE NOT LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE
PAINTS, GASOLINE, ALCOHOL OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE
NOT LIMITED TO;COAL, MAGNESIUM, GRAIN OR GUN POWDER. TO REDUCE THE RISK OF
HEALTH HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.

Operation when dusts tank is full
1. The dust inside the dust bucket is full. (Fig 1)
2. Turn off the switch. (Fig 2)
3. Unplug the power cord. (Fig3)
4. Release the buckle. (Fig 4)
5. Raise the nose assembly from the dust container. (Fig 5)
6. Put out he cloth filter. (Fig 6)
7.Pour out the garbage. (Fig 7)

Operation of water cleaning
1. Make sure the power cord is disconnected from the socket.(Fig1)
2. Cover the bottom cap basket with watering absorbing sponge, make sure cover the whole
basket. (Fig2)
3.Put out he cloth filter. (Fig 3)
4. Place the Head assembly on the dust bucket that has been fitted with the filter assembly
and lock it with both sides of the buckle. (Fig 4)
5. Insert the power cord. (Fig 5)
6. Start the switch. (Fig 6)
7. Install the required suction accessories on the hose assembly. (Fig 7)
8. When the water level reaches the maximum capacity, the safety valve will automatically
start, then the suction did not produce suction, the barrel of water poured out. (Fig. 8)
9.Off the switch. (Fig 9)
10. Disconnect the power cord from the socket. (Fig 10)
11. To ensure the best results of water absorption, please remove the air filter sponge,
hand-wring dry after drainag, and then use again. (Fig 11)
12. Wash the sewaged sponge with cleaning water, hand-wring dry after washing, then be
used again. (Fig 12)

WARNING: BE SURE TO READ, UNDERSTAND, AND APPLY INFORMATION, ENTITLED ‘SAFETY
INSTRUCTIONS & WARNINGS’. DO NOT VACUUM IN AREAS WITH FLAMMABLE GASES,
VAPORS, OR EXPLOSIVE DUSTS IN THE AIR. FLAMMABLE GASES OR VAPORS INCLUDE BUT
ARE NOT LIMITED TO; LIGHTER FLUID, SOLVENT TYPE CLEANERS, OIL-BASE PAINTS,
GASOLINE, ALCOHOL OR AEROSOL SPRAYS. EXPLOSIVE DUSTS INCLUDE BUT ARE NOT
LIMITED TO; COAL, MAGNESIUM, GRAIN OR GUN POWDER. TO REDUCE THE RISK OF HEALTH
HAZARDS FROM VAPORS OR DUST, DO NOT VACUUM TOXIC MATERIALS.
Operation of blower
WARNING: ALWAYS WEAR SAFETY GOGGLES BEFORE USING BLOWER.
WARNING: KEEP BY STANDERS CLEAR FROM BLOWING DEBRIS.
WARNING: WEAR A DUST MASK IF BLOWING CREATES DUST THAT MIGHT BE INHALED.
1. Make sure that the power cord is disconnected from the socket. (Fig 1)
2. Unscrew the inserted hose assembly from the suction port with a left-hand rotation. (Fig 2)
3. Insert the main cannula of the hose assembly into the air outlet at the back of the head
and tighten it with the right hand rotation. (Fig 3)
4. Insert the power cord. (Fig 4)
5. Start the switch button. (Fig 5)
6. Hold the hose assembly, let outlet port aimed at the leaves and so on. (Fig 6)

Filter cleaning
1. Periodically check the cleaning filter to maintain performance.
2. If the suction very tiny dust, the filter may need more frequent cleaning.
3. Wash filter sponge with cold or warm water without the use of detergent. (Fig 1 Fig 2)
4. Keep the cleaned parts in a wide area to dry, try to keep dry and dry for at least 24 hours.
Do not put the filter in a dishwasher, washing machine, roller dryer, oven, microwave oven
or open flame.(Fig3)
Maintenance
①After cleaning the barrels, filters and related accessories, check if leaks. After each use,
clean the filter and do not use a wet filter at all times.
②Check the plug if damage, place the plug.
③Check whether there is something plug the air intake, if any, please clean.
④carefully put the machine, do not beat.
⑤keep the machine dry.
⑥if filter covered with dust, wash with cold water, if necessary, may also use neutral
detergent cleaning, Do not use corrosive objects to clean.Do not put entire head directly in
the water cleaning.
⑦Do not let the machine work for a long time, each working time is best in 2 hours,
otherwise will reduce the machine life.
⑧after a long time the filter will be covered the dust, suction will be weakened. To avoid the
weakening of suction, always clean the filter.
⑨if any abnormal vibration or noise or smell, Must immediately stop using the machine, and
maintenance.

TROUBLESHOOTING
WARNING! TO REDUCE THE RISK OF ELECTRIC SHOCK-UNPLUG BEFORE
TROUBLESHOOTING
Symptom
Possible Causes
Corrective Action
Vacuum will not operate
1) No power supply.
1) Check power supply –cord,
breakers, fuses.
2) Faulty power cord.
2) Unplug and check the power cord.
If damaged,have it repaired by a
professional.
3) Container full.
3) Empty container.
Dust comes out from motor
cover.
1) The cartridge filter or collection
bag is missing or damaged.
1) Attach or replace cartridge filter or
collection bag.
Reduced efficiency and
motor/speed vibration.
1) There is a blockage in the nozzle
or hose, or the container inlet. Or
dust filter blocked by fine dust.
1) Check nozzle, hose and
container inlets for blockage. Take
off the filter and clean it. Or install
new cartridge filter.
Correct Disposal of this product
This marking indicates that this product should not be disposed with other household wastes throughout the EU.
To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it
responsibly to promote the sustainable reuse of material resources. To return your used device, please use the
return and collection systems or contact the retailer where the product was purchased. They can take this product
for environmental safe recycling.
Table of contents
Other Faber Vacuum Cleaner manuals
Popular Vacuum Cleaner manuals by other brands

LG
LG VK78161R owner's manual

Windsor
Windsor SENSOR S12 user manual

Kent Euroclean
Kent Euroclean SelectVac 12DC 56648092 Operator's manual and parts list

Allaway
Allaway C 40 PREMIUM Instructions for use and maintenance

Kärcher
Kärcher VC 6 Cordless ourFamily Original operating instructions

LG
LG VC3319YM owner's manual