Fagor Dro NV-300T User manual

Installation Manual - Page: 1
NV-300T/301T Man: 9910 Soft: 2.xx
INDEX
Introduction .............................................................................................1
Declaration of conformity...........................................................................2
Safety conditions........................................................................................3
Warranty terms ...........................................................................................5
Material returning terms..............................................................................6
1. Unit description ................................................................................7
1.1 Front panel .........................................................................................7
1.2 Rear panel ........................................................................................10
1.3 General characteristics .......................................................................11
2. Connections ....................................................................................12
2.1 connection of the feedback systems...................................................12
2.2 Power and machine connection.........................................................13
2.3 Turning the unit on and off...............................................................13
3. Parameter setting............................................................................14
3.1 Parameters to configure axis count and display .................................16
Appendix ................................................................................................20
Error codes...............................................................................................20
Maintenance.............................................................................................21
INTRODUCTION
Attention: Before starting up the DRO, carefully read the instructions of
Chapter 2 in the Installation Manual.
The DRO must not be powered-on until verifying that the
machine complies with the "89/392/CEE" Directive.

Page: 2 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
DECLARATIONOFCONFORMITY
Manufacturer: Fagor Automation, S. Coop.
Barrio de San Andrés s/n, C.P. 20500, Mondragón -Guipúzcoa
(ESPAÑA)
We hereby declare, under our resposibility that the product:
Digital Readout (DRO) Fagor NV-300T / NV-301T
meets the following directives:
SAFETY:
EN 60204-1Machinesafety.Electricalequipmentofthemachines.
ELECTROMAGNETIC COMPATIBILITY:
EN 50081-2 Emission
EN 55011 Radiated. Class A, Group 1.
EN 55011 Conducted. Class A, Group 1.
EN 50082-2 Immunity
EN 61000-4-2 Electrostatic Discharges.
EN 61000-4-3 RadiofrequencyRadiatedElectromagneticFields
EN 61000-4-4 Bursts and fast transients.
EN 61000-4-5 Power surges
EN 61000-4-6 Conducted disturbance induced by radio
frequency fields.
EN 61000-4-11 Voltage fluctuations and Outages.
ENV 50204 Electromagnetic fields radiated by wireless telephones.
As instructed by the European Community Directives on Low Voltage:
73/23/EEC, (and the 93/68/EEC amendment) on Machine Safety 89/392/
EEC and 89/336/EEC on Electromagnetic Compatibility.
In Mondragón, on April 1st, 1996

Installation Manual - Page: 3
NV-300T/301T Man: 9910 Soft: 2.xx
SAFETYCONDITIONS
Read the following safety measures in order to prevent damage to
personnel, to this product and to those products connected to it.
FagorAutomationshallnot be heldresponsiblefor anyphysicalor material
damage derived from the violation of these basic safety regulations.
Do not manipulate the inside of the unit
Only personnel authorized by Fagor Automation may
manipulate the inside of this unit.
Do not manipulate the connectors with the unit connected toAC
power.
Before manipulating the connectors (mains, feedback, etc.)
make sure that the unit is not connected to AC power.
Use proper Mains AC power cables
To avoid risks, use only the Mains AC cables recommended for this unit.
Avoid electrical overloads
In order to avoid electrical discharges and fire hazards, do not apply electrical
voltage outside the range indicated in chapter 2 of this manual
Ground connection
In order to avoid electrical discharges, connect the ground terminals of all the
modules to the main ground terminal. Before connecting the inputs and
outputs of this unit, make sure that all the grounding connections are properly
made.
Before powering the unit up, make sure that it is connected to ground
In order to avoid electrical discharges, make sure that all the grounding
connections are properly made.
Ambient conditions
Respect the temperature and humidity ranges specified on the chapter about
technical characteristics in this manual (1.3).
Do not work in explosive environments
In order to avoid risks, damage, do not work in explosive environments.

Page: 4 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
Working environment
This unit is ready to be used in Industrial Environments complying with the
directives and regulations effective in the European Community
Install the unit in the right place
It is recommended, whenever possible, to instal the DRO so its power switch
of the back panel is at a distance between 0.7 m (27.5 inches) and 1.7 m (5.6
ft) off the floor and away from direct sunlight, hot air, coolants, chemical
products, blows as well as from relays, or high electromagnetic fields (about
0.5m or 20 inches) that could damage it.
This unit complies with the European directives on electromagnetic
compatibility. Nevertheless, it is recommended to keep it away from sources
of electromagnetic disturbance such as.
- Powerful loads connected to the same AC power line as this equipment.
- Nearby portable transmitters (Radio-telephones, Ham radio transmitters).
- Nearby radio / TC transmitters.
- Nearby arc welding machines.
- Nearby High Voltage power lines.
- Disturbance generating elements of the machine.
- Etc.
Safety symbols
Symbols which may appear on the manual
WARNING. symbol
Ithasanassociatedtextindicatingthoseactionsoroperationsmayhurt
people or damage products.
Symbols that may be carried on the product
WARNING. symbol
Ithasanassociatedtextindicatingthoseactionsoroperationsmayhurt
people or damage products.
"ELECTRICAL SHOCK" symbol
It indicates that point may be under electrical voltage
"GROUND PROTECTION" symbol
It indicates that point must be connected to the main ground point of
the machine as protection for people and units.

Installation Manual - Page: 5
NV-300T/301T Man: 9910 Soft: 2.xx
WARRANTYTERMS
WARRANTY
All products manufactured or marketed by Fagor Automation has a war-
ranty period of 12 months from the day they are shipped out of our ware-
houses.
The mentioned warranty covers repair material and labor costs, at FAGOR
facilities, incurred in the repair of the products.
Within the warranty period, Fagor will repair or replace the products veri-
fied as being defective.
FAGOR is committed to repairing or replacing its products from the time
when the first such product was launched up to 8 years after such product
has disappeared from the product catalog.
It is entirely up to FAGOR to determine whether a repair is to be considered
under warranty.
EXCLUDING CLAUSES
The repair will take place at our facilities. Therefore, all shipping expenses
as well as travelling expenses incurred by technical personnel are NOT
under warranty even when the unit is under warranty.
This warranty will be applied so long as the equipment has been installed
according to the instructions, it has not been mistreated or damaged by accident
or negligence and has been manipulated by personnel authorized by FAGOR.
If once the service call or repair has been completed, the cause of the failure
is not to be blamed the FAGOR product, the customer must cover all
generated expenses according to current fees.
No other implicit or explicit warranty is covered and FAGOR AUTOMA-
TION shall not be held responsible, under any circumstances, of the damage
which could be originated.
SERVICE CONTRACTS
Service and Maintenance Contracts are available for the customer within
the warranty period as well as outside of it.

Page: 6 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
MATERIALRETURNINGTERMS
When returning the DRO, pack it in its original package and with its original
packaging material. If not available, pack it as follows:
1.- Get a cardboard box whose three inside dimensions are at least 15 cm (6
inches) larger than those of the unit. The cardboard being used to make the
box must have a resistance of 170 Kg (375 lb.).
2.- When sending it to a Fagor Automation office for repair, attach a label
indicating the owner of the unit, person to contact, type of unit, serial number,
symptom and a brief description of the problem.
3.- Wrap the unit in a polyethylene roll or similar material to protect it.
4.- Pad the unit inside the cardboard box with poly-utherane foam on all sides.
5.- Seal the cardboard box with packing tape or industrial staples.

Installation Manual - Page: 7
NV-300T/301T Man: 9910 Soft: 2.xx
1. UNITDESCRIPTION
This NV-300T / NV-301T DRO is designed for industrial environments,
especially on lathes
It can display the position of two axes or one axis and the combination of the
second axis with a third one.
1.1 FRONTPANEL
3rd display
Each axis display has eight 14.1mm high LEDs and another one for the minus
sign (-).
ABS-This lamp stays on when operating in absolute mode and off when in
incremental mode. To access or quit this mode, use the key.
ΦΦ
ΦΦ
Φ- This lamp stays on when operating in diameter mode. In this mode, the
DRO displays twice the actual axis movement.To access it or quit it, use
the key.
HOLD- This lamp comes on when "freezing" the axis position by
pressing and the axis key.

Page: 8 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
INCH- This lamp stays on when working in inches and off when doing
it in millimeters. To access it or quit it, press
This lamp stays on during machine reference search . To access
it or quit it, press key.
TOOL- This lamp stays on when setting the tool.
"PROBE" This lamp is not used on this model.
3er display The rightmost digit shows a "1", a "2" or is off to indicate that
the Z axis display (2nd one) corresponds to "Z1", "Z2" or to the
combination of "Z1+Z2" respectively.
This selection rotates by pressing . It also shows the text
"tool" followed by the number of the active tool corresponding
to the XZ coordinates shown on the other displays.
Keys to select the first or second axis respectively.
Key to select whether the 2nd display corresponds to "Z1", "Z2" or to
the combination of "Z1+Z2" respectively. Every time this key is pressed,
the rightmost digit of the 3rd display rotates from "1" to "2" and off
respectively.
Is used for carrying out the home (reference) search.
Is used for rotating from the incremental to the absolute mode and vice
versa
Is used to turn the display off while keeping track of the axes position
at all times. This key must be pressed before turning the unit's power off
by the main switch on the back of the unit.
Is used to validate an operation.
Is used to cancel or abort an operation already initiated.

Installation Manual - Page: 9
NV-300T/301T Man: 9910 Soft: 2.xx
Is used to display the actual X axis movement or its double.
These keys are used for entering values.
Thisoneis adualpurpose keyandisusedforenteringvaluesand making
a tool change.
Is used to change the sign of the entered value or change from fine to
coarse resolution and vice versa.
This one is a dual purpose key and is also used to toggle between
"millimeters" and "inch" display units.
Is used for “freezing” the display of the feedback even though the axis
moves.
This key is used for calculating the taper (angle) of a part.

Page: 10 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
1.2 REARPANEL
Dimensions of the Built-in model:
On the back of the unit the following items may be found:
1.- Power switch. When the unit is turned off by this switch, the DRO no
longerreadsaxis position. Therefore, it is recommended to use the key
atthe front panel to turnthedisplayoff so the DROcontinueskeepingtrack
of the axes position when they are moved.
2.- Three-prong power connector for AC and ground connection.
3.- M6 mm terminal for general machine ground connection.
Some of the following connectors might not be available depending on
specific models:

Installation Manual - Page: 11
NV-300T/301T Man: 9910 Soft: 2.xx
X3.- SUB-D HD type 15-pin female connector for 1st axis feedback device
(scale or encoder).
X4.- SUB-D HD type 15-pin female connector for 2nd axis feedback device
(scale or encoder).
X5.- SUB-D HD type 15-pin female connector for 3rd axis feedback device
(scale or encoder).
X7.- SUB-D type 9-pin male connector for the RS-232-C (Optional).
This connector as well as the RS232C option are not described here;
but on a supplement for it.
WARNING
Do not handle the connectors while the unit is under power.
Before handling the connectors (mains, feedback, etc.)
make sure that the unit is not under power.
It is NOT enough to turn the display off by using the
key at the keyboard.
1.3 GENERALCHARACTERISTICS
Universal Power Supply between 100V AC and 240V AC +10% -15%
Mains frequency of 0 Hz (DC) and beteen 45 Hz and 400 Hz
Power outages of up to 20 milliseconds.
10-year memory backup of installation parameters even when the unit is off.
The operating temperature inside the DRO enclosure must be between 5º C
and 45º C (41ºF and 113ºF).
The storage temperature inside the DRO enclosure must be -25º C and +70º
C (-13º F and 158º F).
Maximum relative humidity: 95% non condensing at 45ºC (113ºF).
Front Panel Sealing: IP54 (DIN 40050), Rear panel: IP4X (DIN40050) except
for built-in models in which case is: IP20.

Page: 12 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
2. CONNECTIONS
2.1 CONNECTIONOFTHE FEEDBACKSYSTEMS
The feedback systems (scales or encoders) are connected via SUB-D HD type
15-pin female connectors: X3, X4 and X5.
Characteristics of feedback inputs: X3, X4 and X5:
- +5V input consumption: 250 mA
- Admits square-wave signal (TTL). (A, B, Io)
- 1Vpp voltage modulated sinewave signals (NV-301T model)
- Maximum frequency: 250 KHz, minimum separation between flanks:
950nsec.
- Phase shift 90º ±20º, hysteresis 0.25 V, Vmax 7V.
Maximum input current: 3 mA.
- High threshold (logic state 1) 2.4V < VIH < 5V
- Low threshold (logic state 0) 0.0V < VIL < 0.8V
* Not available at the NV-300T model
Pin Signal Function
1 A
Feedback signals
2/A*
3 B
4/B*
5I0 Reference signal
6/Io*
7Alarm Feedback alarm
8/Alarm*
9+5V Power to feedback device
10 Not connected Unused
11 0V Power to feedback device
12 Not connected Unused
13 Not connected Unused
14 Not connected Unused
15 Chassis Shield
15
112
6

Installation Manual - Page: 13
NV-300T/301T Man: 9910 Soft: 2.xx
2.2 POWERANDMACHINECONNECTION
This DRO can be connected to an AC voltage anywhere between 100V AC
and 264 V AC +10% -15% with a frequency between 45 Hz and 400 Hz
without having to select it depending on the country where they are installed
thanks to their universal power supply.
Always mount it vertically so its keyboard is within operator's reach and its
digits are easily visible (at operator's eye level).
Do not connect or disconnect the DRO connectors while it is under power.
Connect all metallic parts to a common point on the machine tool and it to the
general ground point. Use cables of enough gage (no thinner than 8 mm2).
2.3 TURNING THEUNITONAND OFF
Turning the unit ON
The unit is turned on by actuating on the power switch of the rear panel
The DRO runs a self-test and shows on the X axis display the text: "FAGORdro"
if everything is OK and the error number if otherwise. See the appendix at the
end of this manual.
Turning the unit OFF
If you press the DRO turns off the displays while maintaining the power
supply to the feedback systems and goes on reading the position of the axes
at all times. This is not the case when the equipment is switched off by means
of the switch on its rear panel.
To reset the displays, just press this key again, on condition that the DRO is
getting voltage (plugged in and with the switch on the rear panel on).
Notes:
- Before powering the DRO down with the switch on the rear panel or disconnecting
it from mains, it is a good idea to press the key in order to store the current
position of the axes permanently.
- If the unit is powered down with its rear panel switch or there is a power outage
without previously having pressed , the DRO will keep the last position of the
axes for at least 30 minutes.
- The unit will display ERROR 2 when powered back up if the position reading was
lost when turned off while the axes were moving or after the accidental backup
period has expired without having saved the current position by previously press-
ing .

Page: 14 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
3. PARAMETERSETTING
This DRO has a number of installation parameters to configure it for a
particular application.
The format for these parameters depends on whether they are general or
particular for each axis.
. If it affects the axes, the parameter number (PAR??) appears at each axis
and the corresponding axis key must be pressed to modify it.
. If it is a general parameter and there are more than one axis, the Xdisplay
will show the parameter number and the Zits current value; if there is only
one axis, its number will appear on the Xdisplay and, after pressing ,
its value.
There are several kinds of parameters depending on how to set them:
· With binary values. The value of each digit toggles between "0" and "1"
whenpressingitscorrespondingkeyfrom to where corresponds
to the rightmost digit and to the leftmost one.
· Numeric values, usually with the corresponding axis resolution, they are
entered as regular preset.
· Options, the value is changed by pressing +-which will make the various
options appear in a cyclic way.
To edit a parameter, the DRO displays must be on. Then press CON
OFF .
The X axis display shows the word "COdE". Then key in: 060496
Then, select the axis affected by this parameter.
Once in regular display mode, parameter PAR05 (scaling factor) may also
be recalled by pressing C, so the work mode may be changed
without having to go through all the parameters previous to the desired
one.
To go directly to a particular parameter without going through the
previous ones, (once in parameter editing mode) press:
[parameter Nr.] ENTER .

Installation Manual - Page: 15
NV-300T/301T Man: 9910 Soft: 2.xx
To end editing a parameter, follow one of these steps:
. Press ENTER , to save the displayed value.
. Press Cto cancel the change and recover the previous value or---
. Press the other axis key (if it is an axis parameter) to save the display
value and go on to the editing it for the other axis selected.
To modify a parameter, press ENTER to go on to the next one or 12to return
to the previous one. Then, select the axis affecting this parameter.
To quit the parameter editing mode:
Press C
To recover the factory set for the installation parameters:
While displaying parameter PAR00, press:

Page: 16 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
3.1 PARAMETERSTOCONFIGUREAXISCOUNTANDDISPLAY
The digits of digital parameters refer to the digits on the axis displays so digit
"1" corresponds to the rightmost digit and "8" to the leftmost digit.
XXXXXXXX
87654321
PARA-
METER FUNCTION
PAR00 Feedback configuration, different for each axis. Binary type.
Digit
8 Direction of the coded Io (0 = Increasing, 1 = Decreasing)
7 Pitch of the coded Io (0 = 20 mm, 1 = 100mm)
6 Type of linear scale's Io (0 = Fix, 1 = Coded)
5 Feedback resolution units (0 = microns, 1= inches)
4 Not being used at this time. Must be set to "0".
3 Differential feedback signals (0 = No, 1 = Yes)
The NV-300T model cannto be set to "1" (Yes).
2 Type of feedback signals (0 = TTL, 1 = 1 Vpp)
The NV-300T model cannto be set to "1" (Vpp).
1 Counting direction (0 = normal,1 = reverse)
If an axis count increases or decreases in the opposite direction to
the one desired, change the value of this digit.

Installation Manual - Page: 17
NV-300T/301T Man: 9910 Soft: 2.xx
PAR01 Feedback resolution. Independent for each axis.
Possible values: from 0.1µm up to 1 mm (0.000005" to 0.03937").
Factory setting: 5(µm).
PAR02 TTL multiplying factor (subdivision). Independent for each axis.
Options: x4, x2, x1 and x0.5.
The selection of these values rotates by pressing
The factory setting is: x4 and it is the one used for FAGOR scales.
When using encoders, it should be calculating according to the
number of pulses of the encoder, leadscrew pitch and the desired
resolution as per the formula:
Encoder (lines/turn)= Leadscrew pitch (mm/turn)
Resolution (mm/pulse) xF
Where "xF" would be the multiplying factor to be applied.
PAR03 External multiplying factor for when using semi-absolute feedback
devices (distance-coded Io) or sinewave signals (NV-301T).
Independent for each axis.
Options: 1, 5, 10, 20, 25, 50.
Factory setting: 1
For example, for FAGOR scales: M0X, C0X or FOT, set this
parameter to 5.
PAR05 Scaling or shrink factor. Independent for each axis, numeric value
within ±9,999.
A "0" value means that no factor is to be applied. It is applied onto
the coordinates to be displayed after compensating for table sag. It
is not applied when reading with respect to machine reference cero
(led on).
The factory setting is: "0".

Page: 18 - Installation Manual NV-300T/301T Man: 9910 Soft: 2.xx
PAR08 Indicateswhetherthealarmsforfeedrate,travellimitsandfeedback
will be activated or not.
Digit
8, 7, 6 Not being used at this time. Must be set to "0".
5 Detect feedback signal weakness on NVxx1 models.
4 Value for the feedback alarm contact (0=low, 1=high)
3 Detect feedback alarm provided by the scale.
2 Detect travel limits (PAR12 and PAR13).
1 Detect feedback speed alarma.
Possible values: 0 (alarms off) and "1" (alarms on).
Factory values: 0
Thefeedback (.. ... ..) andtravellimit overrunalarms(axisdisplay
blinking) will be displayed if the corresponding bit of
PAR08 = "1".
The blinking axis error is cleared by returning the axis within its
limits
The speed alarm is cleared by pressing C.
PAR09 Axis sag compensation. Independent for each axis.
Numeric value within ±99.999 millimeters per meter.
Factory setting: 0.
Notes: Even when selecting the display in inches, this value
MUST ALWAYS BE IN MILLIMETERS.
1 inch = 25.4 mm
PAR10 Offsetofthereferencepointwithrespecttothereferencezeroofthe
scale, independent for each axis.
Numeric value in resolution units for each axis.
Factory setting: 0.
This value will be in mm or inches depending on whether the INCH
LED is off or on.

Installation Manual - Page: 19
NV-300T/301T Man: 9910 Soft: 2.xx
PAR11 Miscellaneous, binary.
Digit
8, 7, 6, 5, 4, 3, 2 Not being used. Must be set to "0".
1 The key affects one axis ( = 0) or both ( = 1).
If it affects by axis, after pressing one must press the axis
key.
Itmaytogglefrom absolute reading mode to incremental. This
parameter determines whether this toggle affects one axis or
both.
Factory setting: "1"
PAR12 To set the negative axis travel limit.
Possible values: between -99999.999 and 0.
Whenthe axis exceeds thisdistance,the corresponding axis display
starts blinking until it is moved back into the work zone.
This value will be in mm or inches depending on whether the INCH
LED is off or on.
PAR13 To set the positive axis travel limit.
Possible values: between 0 and 99999.999
Whenthe axis exceeds thisdistance,the corresponding axis display
starts blinking until it is moved back into the work zone.
This value will be in mm or inches depending on whether the INCH
LED is off or on.
PAR 14 To carry out the home search when the feedback device does NOT
have reference marks "Io" (for example, FAGOR MKT scales), this
parameter must be set to "1".
This way it is possible to preset a home value in Machine Reference
mode. Factory setting = "0".