
About this manual
This user manual is an integral part
of the Falco Systems WMA-005
amplifier product. Please read it
carefully and pay attention to the
recommendations and the
instructions for safe use.
General description
The Falco Systems WMA-005 is a
high voltage amplifier that runs from
an 18 – 30V DC power supply and
can be battery powered if required,
e.g. for use in a Faraday cage. Its
internal high voltage generator is
inductor-free and hence does not
spread magnetic interference in
sensitive experimental setups. Its
large voltage range makes it an
excellent choice for use with MEMS
devices, EO-modulators, PZT (piezo)
positioning systems, beam steering
components, and many more.
The amplifiers’ full-power frequency
response has a -3dB corner
frequency at 20kHz. The input
impedance is 100kΩand the output
50kΩ.
The output noise is at this price level
impressively low at 3mVrms. For
extremely low noise applications
where bandwidth is not an issue, a
dedicated WMA-005LF version is
available that contains an output low
pass filter capacitor which reduces
the bandwidth to 50Hz, but makes
the noise drop to 0.1mVrms. This
bandwidth-limited amplifier is ideal
for MEMS or piezo positioning with
manual voltage adjustment requiring
extremely low noise.
The WMA-005 contains an over-
voltage protection for the daily use
and abuse in the laboratory and is
long-term short-circuit proof. The
input (indicated “Input” on the WMA-
005 label), output (indicated
“Output”) and DC power supply
(Indicated “18 – 30V DC 120mA”)
connections are all standard BNC.
The amplification is 20x (fixed). With
a range of –75V to +75V, a –3dB
bandwidth of 20kHz, possibility for
battery powered operation, and
below 3mVrms output noise, this
amplifier will enable many
measurements in different
applications.
Safety
- This product is able to produce over
75V, but the 50kΩoutput impedance
limits the current to a rather safe
maximum of 1.5mA. Although this
voltage is painful it will under normal
circumstances not be lethal.
Nevertheless take care. This is a
high voltage unit and safety
measures should be taken
accordingly.
- The internal circuitry of the amplifier
operates at high voltage. Only
qualified personnel from Falco
Systems should service this
amplifier.
- When the amplifier is turned on or
off, a short voltage spike may appear
at the output which may damage
circuitry already connected to it.
- Replace the fuse with 250V
315mAT 5x20mm rated fuses only.
- The Falco Systems WMA-005 is
only suitable for indoor use in a class
!