manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. F&F
  6. •
  7. Relay
  8. •
  9. F&F BIS-416 User manual

F&F BIS-416 User manual

Other F&F Relay manuals

F&F FW-R2D User manual

F&F

F&F FW-R2D User manual

F&F BIS-410i User manual

F&F

F&F BIS-410i User manual

F&F PP-1Z-LED Pico User manual

F&F

F&F PP-1Z-LED Pico User manual

F&F PCS-516UNI User manual

F&F

F&F PCS-516UNI User manual

F&F BIS-411 User manual

F&F

F&F BIS-411 User manual

F&F BIS-411B-LED User manual

F&F

F&F BIS-411B-LED User manual

F&F 5908312592389 User manual

F&F

F&F 5908312592389 User manual

F&F FW-R1D User manual

F&F

F&F FW-R1D User manual

F&F BIS-410 User manual

F&F

F&F BIS-410 User manual

F&F BIS-411i User manual

F&F

F&F BIS-411i User manual

F&F PP-1P User manual

F&F

F&F PP-1P User manual

F&F 5908312595649 User manual

F&F

F&F 5908312595649 User manual

F&F BIS-412M 24V User manual

F&F

F&F BIS-412M 24V User manual

F&F PK-1Z-LED 230 V User manual

F&F

F&F PK-1Z-LED 230 V User manual

F&F BIS-413M User manual

F&F

F&F BIS-413M User manual

F&F PP-1P Pico User manual

F&F

F&F PP-1P Pico User manual

F&F BIS-413 User manual

F&F

F&F BIS-413 User manual

F&F PK-2Z-LED 24 V User manual

F&F

F&F PK-2Z-LED 24 V User manual

F&F BIS-413M-LED User manual

F&F

F&F BIS-413M-LED User manual

F&F PK-2P User manual

F&F

F&F PK-2P User manual

F&F PP-2Z User manual

F&F

F&F PP-2Z User manual

F&F EPP-618 User manual

F&F

F&F EPP-618 User manual

F&F BIS-410-24V User manual

F&F

F&F BIS-410-24V User manual

F&F BIS-409 User manual

F&F

F&F BIS-409 User manual

Popular Relay manuals by other brands

Shelly Pro Series user manual

Shelly

Shelly Pro Series user manual

GE MVAX 11 Technical manual

GE

GE MVAX 11 Technical manual

ABB RELION REF615R manual

ABB

ABB RELION REF615R manual

Pilz PNOZ X10 Technical instructions

Pilz

Pilz PNOZ X10 Technical instructions

Kemo Electronic B197 quick guide

Kemo Electronic

Kemo Electronic B197 quick guide

Seg MRM3 manual

Seg

Seg MRM3 manual

Basler BE1-700C manual

Basler

Basler BE1-700C manual

CD Automation REVEX 2PH 280A user manual

CD Automation

CD Automation REVEX 2PH 280A user manual

ABB SPAJ 142 C User manual and technical description

ABB

ABB SPAJ 142 C User manual and technical description

Ruelco 1S04 Operation manual

Ruelco

Ruelco 1S04 Operation manual

Basler V3E Z1P B2C1F instruction manual

Basler

Basler V3E Z1P B2C1F instruction manual

Doepke Dupline DSM 2 operating instructions

Doepke

Doepke Dupline DSM 2 operating instructions

Siemens SIRIUS 3RT1966-4D Original operating instructions

Siemens

Siemens SIRIUS 3RT1966-4D Original operating instructions

GE DGP instruction manual

GE

GE DGP instruction manual

Kyongbo Electronics GDR-D01 user manual

Kyongbo Electronics

Kyongbo Electronics GDR-D01 user manual

Siemens SIPROTEC 4 user manual

Siemens

Siemens SIPROTEC 4 user manual

Siemens BD2-AK03X/FS Series installation instructions

Siemens

Siemens BD2-AK03X/FS Series installation instructions

Leuze MSI-SR5B Original operating instructions

Leuze

Leuze MSI-SR5B Original operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

- 3 - - 4 -
- 1 - - 2 -
Purpose
Electronic bistable pulse relay switch that turns on or off lights or
other equipment from several different points with the parallel
connected momentary (bell) control switches.
The relay has two independently controlled channels.
D141222/150119
Specifications
Wiring diagram
Operation
The relay is activated with a current pulse caused by the press of
any momentary (bell) button connected to the relay. Subsequent
pulse will switch the relay off.
The relay has two independently controlled channels.
Control is carried out by means of two separate signal inputs.
Pulse on S1 input controls the R1 output. S2 input and R2 output
operate on the same basis.
The relay does not have a "memory" of the contact position, i.e.
when power returns after power failure, contact of the relay will
be set in the disabled state. This prevents automatic switching of
controlled receivers without supervision after prolonged power
outage.
BISTABLE RELAY
dual-channel
BIS-416
5 9 0 8 3 1 2 5 9 8 2 7 5
power supply V AC
contact / AC-1 load current
control L pulse current < mA
response delay 0.1÷0.2s
power indicator green LED
power consumption
standby 0. W
on 0.6W
working temperature - ÷50°C
terminal 2.5mm screw terminals
tightening torque 0.4Nm
mounting in the Ø60 flush-mounted box
ingress protection I 20
100÷265
2×1NO / 2×[<8A]
5
15
25
²
dimensions Ø54 (□48×43mm), h=20mm
P
NN
2 3 5
L
1
S2
L
64
PWR
N
L
S1 R2
R2
R1
R1
L
S1
S2
N
R1
R2
Installation
Note!
R1
R2
S1
S2
U
1000W 500W
600W
incandescent fluoroscent energy-saving
halogen LED
250W 120W
Power table
The above data are indicative and will heavily depend on the
design of a specific receiver (that is especially important for LED
bulbs, energy-saving lamps, electronic transformers and pulse
power supply units), switching frequency and operating
conditions.
For more information visit: www.fif.com.pl
F&F Filipowski sp. j.
Konstantynowska 79/81 95-200 Pabianice
phone/fax: (+48 42) 215 23 83 / 227 09 71 POLAND
http://www.fif.com.pl e-mail: fif@fif.com.pl
Do not dispose of this device to a garbage bin with other unsorted waste!
In accordance with the Waste Electrical and Electronic Equipment Act
any household electro-waste can be turned in free of charge and in any
quantity to a collection point established for this purpose, as well as to the
store in the event of purchasing new equipment (as per the old for new rule,
regardless of brand). Electro-waste thrown in the garbage bin or abandoned
in the bosom of nature pose a threat to the environment and human health.
WARRANTY. The F&F products are
covered by a warranty of the 24 months
from the date of purchase. Effective only
with proof of purchase. Contact your
dealeror directly with us. More
information how to make a compliant can
be found on the website:
www.fif.com.pl/reklamacje
1. Disconnect the power supply.
2. Mount relay in the flush-mounted box.
3. Connect the power supply cables to PWR group: phase wire L
to terminal 4, neutral wire N to terminal 3.
4. Parallel connected S1 momentary switches (R1 section
control) connect to terminal 2 and phase wire L. Parallel
connected S2 momentary switches (R2 section control)
connect to terminal 1 and phase wire L.
5. Powered receiver of section R1 connect in series to terminal 6
and neutral wire N. Powered receiver of section R2 connect in
series to terminal 5 and neutral wire N.
BIS-416 is compatible with backlit buttons.
X-ON Electronics
Largest Supplier of Electrical and Electronic Components
Click to view similar products for General Purpose Relays category:
Click to view products by F&F manufacturer:
Other Similar products are found below :
APF30318 JVN1AF-4.5V-F PCN-105D3MHZ 5JO-10000S-SIL 5JO-1000CD-SIL 5JO-400CD-SIL LY2S-AC220/240 LYQ20DC12
6031007G 6131406HQ 6-1393099-3 6-1393099-8 6-1393122-4 6-1393123-2 6-1393767-1 6-1393843-7 6-1415012-1 6-1419102-2 6-
1423698-4 6-1608051-6 6-1608067-0 6-1616170-6 6-1616248-2 6-1616282-3 6-1616348-2 6-1616350-1 6-1616350-8 6-1616358-7 6-
1616359-9 6-1616360-9 6-1616931-6 6-1617039-1 6-1617052-1 6-1617090-2 6-1617090-5 6-1617347-5 6-1617353-3 6-1617801-8 6-
1617802-2 6-1618107-9 6-1618248-4 M83536/1-027M CX-4014 MAHC-5494 MAVCD-5419-6 703XCX-120A 7-1393100-5 7-1393111-7
7-1393144-5 7-1393767-8