FEI Baseline 12-0247 User manual

Instruction Manual
FABRICATION
ENTERPRISES INC.
Manufacturer and Master
Distributor of Physical Therapy
and Rehabilitation Products ver 0220
Hydraulic Hand Dynamometer
12-0247
REF
with Digital LCD Gauge

Parts/Specications
Specications 300 lb / 136 kg capacity
Grip adjust range 1.35 in / 3.35 cm
Weight 22.6 oz / 638 gm
Handle
Clamp
5 Level
Adjustment
ON/ENTER
Button
MENU
Button

Purpose / Intended Use
The purpose of this Medical Device is to measure a patient’s grip
strength. It can be used to evaluate initial and ongoing impacts
of hand trauma and dysfunction. The Baseline Hydraulic Hand
Dynamometer can be used to measure isometric force and peak
strength with ve adjustable grip positions. This helps track
strength and rehabilitation over time and is ideal for physical
therapy professionals.
How to Use
Set handle to comfortable grip for patient. Reset max indicator
to zero. Have patient squeeze with maximum force, note reading.
Reset to zero for next test.
Components
• Machined aluminum handle, post and body
• Bronze bellows
• Stainless steel hydraulic tubing
• Teon bushings
• Non-toxic mechanical hydraulic pump uid
• Digital Gauge
Accuracy greater than 97%.
Data
The Baseline® Hydraulic Hand Dynamometer with Digital
LCD Gauge can utilize some of data pertaining to the Jamar®
Hydraulic Hand Dynamometer. The internal workings of both are
hydraulic and bellows-operated.
Hydraulic Hand Dynamometer
with Digital LCD Gauge

ON
ENTER
Press ON/ENTER to
switch ON and OFF.
Press
Instructions
How to zero out unit:
How to view max:
How to turn on/o unit:
Hold
ON
ENTER
Display“____” o n
the LCD. Zero the
unit and save the
Zero Offset.
How to clear max:
ON
ENTER
Hold
CLR
YES?
Conrm
Clear
ON
ENTER
Hold Display“____”
on the LCD.
Clear MAX to
0 and save the
MAX value.
How to switch between LB and KG:
Switch the weight
unit (LB and KG)
Select Unit
Screen
Display“____” on
the LCD. Save
the weight unit.
Exit without
changing
anything.
MENU
Hold Zero Screen
ZERO
UNIT
MENU
Press
MAX
Max Screen Hold
ON
ENTER
MENU
Hold Zero Screen
Max Clear
Screen
MENU
Press Max Screen Hold
ON
ENTER
MENU
Hold Zero Screen
MAX MAX
CLR
Max Clear
Screen
Max Screen Hold
ON
ENTER
MENU
Press
MENU
Hold Zero Screen
MAX MAX
CLR
Screen
Button
MENU
Press
LBKG
SEL MENU
PressHold
ON
ENTER
Hold
ON
ENTER
ZERO
UNIT
ZERO
UNIT
ZERO
UNIT

Norms for Adult Grip Strength
A recent study by Dr. Virgil Mathiowetz indicates that“... individuals using the Baseline®
dynamometer are justied in using the normative data collected with the Jamar®
dynamometer...”
For each test of grip strength, the subject was seated with shoulder adducted and
neutrally rotated with the elbow between 0˚ and 15˚ ulnar deviation.
The standard test protocol used the mean of three strength tests as a resultant score. A
score was taken with both the dominant (right) and non-dominant (left) hands.
The rest results show a relationship between:
• hand strength vs. age
• hand strength of men vs. hand strength of women
• dominant hand strength vs. non-dominant hand strength
Average Performance of all Subjects on Grip Strength (pounds)- Test results
Men Women
Mean SD SE Low High Age Hand Mean SD SE Low High
121.0
104.5
20.6
21.8
3.8
4.0
91
71
167
150
20-24 R
L
70.4
61.0
14.5
13.1
2.8
2.6
46
33
95
88
120.8
110.5
23.0
16.2
4.4
4.4
78
77
158
139
25-29 R
L
74.5
63.5
13.9
12.2
2.7
2.4
48
48
97
97
121.8
110.4
22.4
21.7
4.3
4.2
70
64
170
145
30-34 R
L
78.7
68.0
19.2
17.7
3.8
3.5
46
36
137
115
119.7
112.9
24.0
21.7
4.8
4.2
76
73
176
157
35-39 R
L
74.1
66.3
10.8
11.7
2.2
2.3
50
49
99
91
116.8
112.8
20.7
18.7
4.1
3.7
84
73
165
157
40-44 R
L
70.4
62.3
13.5
13.8
2.4
2.5
38
35
103
94
109.9
100.8
23.0
22.8
4.3
4.3
65
58
155
160
45-49 R
L
62.2
56.0
15.1
12.7
3.0
2.1
39
37
100
83
113.6
101.9
18.1
17.0
3.6
3.4
79
70
151
143
50-54 R
L
65.8
57.3
11.6
10.7
2.3
2.1
38
35
87
76
101.1
83.2
26.7
23.4
5.8
5.1
59
43
154
128
55-59 R
L
57.3
47.3
12.5
11.9
2.5
2.4
33
31
86
76
89.7
76.8
20.4
20.3
4.2
4.1
51
27
137
116
60-64 R
L
55.1
45.7
10.1
10.1
2.0
2.0
37
29
77
66
91.1
76.8
20.6
19.8
4.0
3.8
56
43
131
117
65-69 R
L
49.6
41.0
9.7
8.2
1.8
1.5
35
29
74
63
75.3
64.8
21.5
18.1
4.2
3.7
32
32
108
93
70-74 R
L
49.6
41.5
11.7
10.2
2.2
1.9
33
23
78
67
65.7
55.0
21.0
17.0
4.2
3.4
40
31
135
119
75+ R
L
42.6
37.6
11.0
8.9
2.2
1.7
25
24
65
61
104.3
93.1
28.3
27.6
1.6
1.6
32
27
176
160
All
Subjects
R
L
62.8
53.9
17.0
15.7
0.96
0.88
25
23
137
115
References:
1.Gill D., Reddon J., Renney C., StefanykW.: Hand Dynamometer: Effects ofTrials and Sessions. Perpetual and Motor Skills 61: 195-8, 1985.
2. Everett P., Sills F.: The relationship of Grip Strength to Stature, Somatotype Components, and Anthropometric Measurements of the Hand. The
Research Quarterly 23: 161-6, 1952
3. MathiowetzV., Federman S.,Wiermer D.: Grip and Pinch Strength: Norms for 6 to 19Year Olds. The American Journal of OccupationalTherapy 40:
705-11, 1986
4. MathiowetzV., Donahoe L., Renells C.: Effect of Elbow Position on Grip and Key Pinch Strength.The Journal of Hand Surgery 10A: 694-7, 1985
5. MathiowetzV., Kashman N.,Volland G.,Weber K., Dove M., Rogers S.: Grip and Pinch Strength: Normative Data for Adults. Archives of Physical
Medicine and Rehabilitation 66: 69-74, 1985.

* charts generated from data published in Mathiowetz’s article“Grip and Pinch Strength: Normative Data for Adults”, Archives of
Physical Medicine and Rehabilitation 66: 69-74, 1985
Women
Men
Grip Strength (Dominant Hand)
0
5
10
15
20
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Age
14
9
15
9
14
10
11
6
12
3
10
8
13
10
17
18
17
14
17
16 16
14
16
12
14
11
Percentage Dierece
Grip Strength Dierence Between
Dominant and Non-Dominant Hand
% =
dominant score - non-dominate score
dominate score
0
25
50
75
100
125
121.0 120.8 121.8 119.7
116.8
104.3
65.7
91.1
101.1
89.7
113.6
109.9
75.3
70.4
74.5
78.7
74.1
70.4
62.8
42.6
49.6
57.3 55.1
65.8
62.2
49.6
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Women
Men
Age
Grip Strength (Pounds)
Women
Men
Grip Strength (Dominant Hand)
0
5
10
15
20
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Age
14
9
15
9
14
10
11
6
12
3
10
8
13
10
17
18
17
14
17
16 16
14
16
12
14
11
Percentage Dierece
Grip Strength Dierence Between
Dominant and Non-Dominant Hand
% =
dominant score - non-dominate score
dominate score
0
25
50
75
100
125
121.0 120.8 121.8 119.7
116.8
104.3
65.7
91.1
101.1
89.7
113.6
109.9
75.3
70.4
74.5
78.7
74.1
70.4
62.8
42.6
49.6
57.3 55.1
65.8
62.2
49.6
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Women
Men
Age
Grip Strength (Pounds)
Women
Men
Grip Strength (Dominant Hand)
0
5
10
15
20
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Age
14
9
15
9
14
10
11
6
12
3
10
8
13
10
17
18
17
14
17
16 16
14
16
12
14
11
Percentage Dierece
Grip Strength Dierence Between
Dominant and Non-Dominant Hand
% =
dominant score - non-dominate score
dominate score
0
25
50
75
100
125
121.0 120.8 121.8 119.7
116.8
104.3
65.7
91.1
101.1
89.7
113.6
109.9
75.3
70.4
74.5
78.7
74.1
70.4
62.8
42.6
49.6
57.3 55.1
65.8
62.2
49.6
All Ages75+70-7465-6960-6455-5950-5445-4940-4435-3930-3425-2920-24
Women
Men
Age
Grip Strength (Pounds)


©2021FEI, all rights reserved. Baseline is a registered trademark of Goldberg.
WARRANTY
The Baseline® Hydraulic Hand Dynamometer with Digital LCD
Gauge is warranted for 2 years covering parts and labor from
date of purchase. If unit needs repair, contact your local dealer
or Fabrication Enterprises, Inc.
250 Clearbrook rd, Elmsford NY, 10523 (USA)
tel: 914-345-9300 • 800-431-2830
fax: 914-345-9800 • 800-634-5370
Fabrication Enterprises Inc
250 Clearbrook Road, Suite 240
Elmsford, NY 10523 (USA)
tel: +1-914-345-9300 • 800-431-2830
fax: +1-914-345-9800 • 800-634-5370
FabEnt.com
EC REP
Authorized CE representative:
AJW Technology Consulting GmbH
Königsallee 106
40215 Düsseldorf (Germany)
Table of contents
Other FEI Medical Equipment manuals
Popular Medical Equipment manuals by other brands

Getinge
Getinge Arjohuntleigh Nimbus 3 Professional Instructions for use

Mettler Electronics
Mettler Electronics Sonicator 730 Maintenance manual

Pressalit Care
Pressalit Care R1100 Mounting instruction

Denas MS
Denas MS DENAS-T operating manual

bort medical
bort medical ActiveColor quick guide

AccuVein
AccuVein AV400 user manual