10
TECHNICAL DATA AND PERFORMANCE
Nominal performance IR
Nominal performance IP
Frame 1 2 3
Model 6.1 7.1 9.1 11.1 14.1 17.1 U.M.
Electrical power supply 230-1-50 230-1-50 400-3N-50 230-1-50 400-3N-50 400-3N-50 V-ph-Hz
Cooling (air 35 °C bs / water 12 - 7 °C )
Refrigerating capacity (E) 6,20 7,40 9,40 9,40 10,8 10,8 13,8 17,3 kW
Total input (VB) (E) 2,15 2,85 3,70 3,70 4,15 4,15 5,15 6,65 kW
total EER (VB) (E) 2,88 2,60 2,54 2,54 2,60 2,60 2,68 2,60 -
Water delivery 1066 1273 1617 1617 1858 1858 2374 2976 l/h
Pressure losses (VB) (E) 28 38 26 26 33 33 40 35 kPa
Useful head (VP-VA) 73 58 170 170 152 152 122 96 kPa
Cooling (air 35 °C bs / water 23 - 18 °C )
Refrigerating capacity 7,40 8,90 11,3 11,3 13,0 13,0 16,6 20,8 kW
Total input (VB) 2,20 2,90 3,80 3,80 4,25 4,25 5,30 6,85 kW
Total EER (VB) 3,36 3,07 2,97 2,97 3,06 3,06 3,13 3,04 -
Water delivery 1273 1531 1944 1944 2236 2236 2855 3578 l/h
Pressure losses (VB) (E) 38 53 36 36 46 46 56 49 kPa
Useful head (VP-VA) 58 37 146 146 122 122 82 49 kPa
ESEER(VB)(E) 3,26 2,94 2,88 2,88 2,94 2,94 3,04 2,94 -
Frame 1 2 3
Model 6.1 7.1 9.1 11.1 14.1 17.1 U.M.
Electrical power supply 230-1-50 230-1-50 230-1-50 400-3N-50 230-1-50 400-3N-50 400-3N-50 400-3N-50 V-ph-Hz
Cooling (air 35 °C bs / water 12 - 7 °C )
Refrigerating capacity (E) 6,00 7,10 9,20 9,20 10,6 10,6 13,6 17,1 kW
Total input (VB) (E) 2,15 2,85 3,70 3,70 4,15 4,15 5,15 6,65 kW
Total EER (VB) (E) 2,79 2,49 2,49 2,49 2,55 2,55 2,64 2,57 -
Water delivery 1032 1221 1582 1582 1823 1823 2339 2941 l/h
Pressure losses (VB) (E) 26 35 25 25 32 32 39 34 kPa
Useful head (VP-VA) 75 62 173 173 155 155 124 99 kPa
Cooling (air 35 °C bs / water 23 - 18 °C )
Refrigerating capacity 7,20 8,50 11,0 11,0 12,8 12,8 16,3 20,5 kW
Total input (VB) 2,20 2,90 3,80 3,80 4,25 4,25 5,30 6,85 kW
Total EER (VB) 3,27 2,93 2,89 2,89 3,01 3,01 3,08 2,99 -
Water delivery 1238 1462 1892 1892 2202 2202 2804 3526 l/h
Pressure losses (VB) (E) 36 49 34 34 45 45 54 48 kPa
Useful head (VP-VA) 60 43 150 150 125 125 86 53 kPa
ESEER(VB)(E) 3,16 2,82 2,82 2,82 2,89 2,89 2,99 2,91 -
Heating (air 7 °C bs - 6 °C bu / water 40 - 45 °C )
Heat output (E) 7,00 8,20 10,4 10,4 11,5 11,5 15,3 18,6 kW
Total input (VB) (E) 2,25 2,75 3,65 3,65 4,05 4,05 4,95 6,40 kW
Total COP (VB) (E) 3,11 2,98 2,85 2,85 2,84 2,84 3,09 2,91 -
Water delivery 1204 1410 1789 1789 1978 1978 2632 3199 l/h
Pressure losses (VB) (E) 34 46 31 31 37 37 48 40 kPa
Useful head (VP-VA) 63 47 157 157 143 143 101 79 kPa
Heating (air 7 °C bs - 6 °C bu / water 30 - 35 °C )
Heat output 7,20 8,40 10,6 10,6 11,7 11,7 15,6 19,0 kW
Total input (VB) 1,90 2,35 3,05 3,05 3,40 3,40 4,15 5,40 kW
Total COP (VB) 3,79 3,57 3,48 3,48 3,44 3,44 3,76 3,52 -
Water delivery 1238 1445 1823 1823 2012 2012 2683 3268 l/h
Pressure losses (VB) (E) 36 48 32 32 38 38 50 42 kPa
Useful head (VP-VA) 60 44 155 155 140 140 97 74 kPa
(VB) : only for base version VB
(VP-VA) : only for pump version VP and tank version VA
(E) : data declared according to EUROVENT certification programme