Fervi E022/12 User manual

USE AND
MAINTENANCE MANUAL
Flexible endoscope for mechanical use
with probe
Art. E022/12
ORIGINAL INSTRUCTIONS
fervi.com

MEASURING
INSTRUMENTS
Page 2 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
FOREWORD
Read this manual before any operation
ORIGINAL INSTRUCTIONS
Before starting any operation it is compulsory to read this instruction manual. The guarantee
of smooth operation and full performance of the equipment is highly dependent on the
application of all the instructions contained in this manual.
Operator Qualification
The workers responsible for using this equipment must have all necessary information,
education and receive adequate training regarding safety, including:
a) The conditions of use of the equipment;
b) Foreseeable abnormal situations, pursuant to Article 73 of Legislative Decree
81/08.
We guarantee the equipment's conformity to specifications and technical instructions
described in the Manual on the date of issue, listed on this page; however, the
machine may be subject to potentially major technical changes in the future, without
the Manual being updated.
Therefore, see FERVI for information about modifications that could be implemented.
REV. 2 March 2014
fervi.com

MEASURING
INSTRUMENTS
Page 3 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
CONTENTS
1 INTRODUCTION ........................................................................................ 4
2 GENERAL INFORMATION........................................................................... 5
2.1 Battery ..........................................................................................................................5
3 PARTS LIST............................................................................................... 6
4 TECHNICAL CHARACTERISTICS................................................................. 7
5 HOW TO USE ............................................................................................. 8
5.1 Installing the battery ....................................................................................................8
5.2 Connecting the display to the camera and sensor unit ..................................................8
5.3 Installation of accessories ............................................................................................8
5.4 Operating procedures ...................................................................................................9
6 MAINTENANCE ........................................................................................ 10
6.1 Frequent problems ......................................................................................................10
fervi.com

MEASURING
INSTRUMENTS
Page 4 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
1 INTRODUCTION
This product has been designed to be used with mechanical devices or to inspect difficult to
reach areas but MUST NOT be used for purposes not permitted by law (medical, human,
animal, etc.)
The videoscope through new optical and electronic technologies allows the inspection of areas
which are normally difficult to reach, making it easier to diagnose problems with mechanical
parts.
The product is equipped with a 3.5" colour LCD display which is useful for showing clear and
well defined images. The camera is equipped with LED lights that also allow holes or enclosed
parts with no light source to be inspected. It is possible to install on the head of the
equipment several accessories that make it flexible during use:
The magnetic accessory is used to attract small objects.
The mirror is used in order to gain a 90° view.
The hook is used for attaching objects.
Handling Precautions
The probe is flexible to allow work to be performed in difficult to reach areas. Please DO
NOT bend it beyond its limits, or force it (usually the bending radius is 5 cm) in order to
avoid causing permanent damage to the probe.
The display should NEVER be put in contact with liquid and must be kept away from any
splashes. Do not touch the display with acids because it would ruin the plastic protection.
Avoid immersion or contact with corrosive substances, places with the presence of oil or
objects with high temperatures.
If the instrument does not work properly, remove the battery and do not use it until it has
been repaired.
Keep out of the reach of children The instrument is potentially dangerous, if in the hands
of inexperienced people.
Maintain the instrument with care. If any drops escape, look for possible cracks. If it is
damaged, do not use it and have it repaired. This type of problem could be caused by bad
maintenance of the instrument.
Only use the accessories supplied as only those are designed for use with this instrument.
Therefore do not use other accessories with this instrument.
Thoroughly wash and dry your hands before turning the instrument on and off and also
prior to the removal or replacement of the battery.
Protect the device from excessive heat, keep it away from heat sources such as radiators,
stoves, or other products that produce heat. Do not use the instrument next to moving
machinery or in areas where the temperature is over 45°C.
Store the instrument in a dry and ventilated place and in its closed packaging.
fervi.com

MEASURING
INSTRUMENTS
Page 5 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
2 GENERAL INFORMATION
Please observe the following indications to avoid electrical shock and injury to persons:
Read and understand all the instructions before the start of each operation;
Do not remove any labels from the instrument;
Keep the work area clean and well lit, dirty and dark work areas can be causes of
accidents;
Do not use tool in the presence of flammable or explosive gases;
Do not use the instrument near chemical or corrosive substances as they may damage
the quality of the images;
Keep children and unauthorised persons away from the work area during use;
Always take care during operation, using common sense;
Do not place the instrument on unstable floors or surfaces. The instrument may fall,
causing injury to persons and damage to the device itself; Do not bring any type of liquid
in contact with the display;
Do not use the instrument for medical purposes or for use on people or animals;
The instrument is not shock resistant, do not use it as a hammer or allow it to fall.
2.1 Battery
Remove the battery during the cleaning of the instrument;
Remove the battery if not used for a long time;
Be sure to insert the battery according to the correct polarity as indicated on the
instrument;
Do not keep the instrument next to a heat source as this may cause battery to explode.
Make sure that the battery terminals do not come into contact with metal parts.
FOLLOW EXISTING PROVISIONS FOR THE DISPOSAL OF USED BATTERIES.
ATTENTION
Do not continuously turn the instrument off and on, wait at least two seconds between
switching on and off, and vice versa. If you see a strange image, turn the instrument off
and try again.
Do not immerse it in water.
Do not use the instrument if there is moisture inside the camera.
Do not modify the probe or the camera head, they can not be used for any other purpose.
Do not inspect places or things where there is an electrical charge even if minimal.
Take note of the following inspection methods:
oFor walls: for inspections within walls, make sure that the power has been cut in the
whole house;
oFor pipes: if you suspect that a metal tube might be traversed by an electric charge,
please contact a qualified electrician before the inspection. Grounding cables, in
certain cases they can be discharged onto aluminium tubes, charging them with
electricity.
oFor cars: Make sure that the car is turned off during operation. Metals and fluids
under the hood may be hot. Do not put the probe and the camera head into contact
with oils and gasoline.
fervi.com

MEASURING
INSTRUMENTS
Page 6 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
3 PARTS LIST
1Portable screen 4Terminal hook
2Probe and camera head 5Terminal with mirror
3Magnetic terminal
A3.5" LCD Screen DProbe connection
BBattery Compartment EProbe
CInstrument on/off and light adjustment
wheel FCamera head
2
1
3
4
5
B
C
A
D
F
E
fervi.com

MEASURING
INSTRUMENTS
Page 7 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
4 TECHNICAL CHARACTERISTICS
Optical system
Viewing direction Straight
Angled view 60°
Observation depth 50 mm
Distance 2.5 cm ~ 30 cm
Specifications
Camera diameter 12 mm
Image 3.5”LCD
Probe type Flexible
Probe length 90mm
Probe and camera protection IP67
Power supply 1 x 9V alkaline battery
Autonomy Continuous working time >2 hours
Temperature of use 0°C~45°C
Humidity RH 5%~95%
Storage temperature
-
20°C~
60°C,
≤85%without
battery
Light LED
Resolution 320×234 pixels
Size 215x156x96 mm
fervi.com

MEASURING
INSTRUMENTS
Page 8 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
5 HOW TO USE
5.1 Installing the battery
Open the battery compartment using a screwdriver to loosen the screw (Fig. 4)
Insert a 9V alkaline battery (6LR61) into the battery compartment, closing the compartment
and tightening the screw (Fig 5).
5.2 Connecting the display to the camera and sensor unit
The display must be properly connected to the camera
and the probe. While connecting, make sure that the
ends of the two units are properly aligned (Fig. 6). Once
aligned, tighten the locking ring with your fingers.
5.3 Installation of accessories
All three accessories included in the package (Fig. 2) are connected to the camera in the
same way. As shown in Fig 7, hold the camera, slide the semicircular part of the accessories
into the camera head, rotate 90° to lock the accessories in place, Fig 8.
fervi.com

MEASURING
INSTRUMENTS
Page 9 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
5.4 Operating procedures
Position the display for a complete view (Fig. 9) . Turn the wheel towards the screen to turn
on the instrument. The wheel will now serve to adjust the intensity of the LED Lights (Fig.
10), which are a source of illumination for the camera.
This tool has been designed to allow the inspection of hard to reach areas. You can use the
accessories to collect o-rings, screws and metal parts.
fervi.com

MEASURING
INSTRUMENTS
Page 10 of 10
All rights are reserved of reproduction and dissemination of this Technical Manual and documentation cited and/or attached. It is expressly forbidden to reproduce, publish or distribute any information from this Manual. Copyright by FERVI
6 MAINTENANCE
The instrument must only be operated by qualified personnel who have read these
instructions carefully.
Damaged parts must be replaced by qualified personnel with other appropriate and
original parts to avoid the possibility of electric shock.
Do not disassemble any part of the instrument, with the exception of those parts where
disassembly is explained in this manual.
Keep the appliance clean, do not use acetone or aggressive liquids for cleaning. To
clean, use a soft cloth. Wipe the LCD screen gently with a clean dry cloth. Remove the
battery before cleaning.
After the completion of any maintenance or cleaning, ask a qualified person to ensure
the proper functioning of the instrument.
Do not use the instrument in the event it emits smoke.
Remove the battery and ask qualified personnel to perform an inspection if the
following situations occur:
oIf liquid has been spilled on the instrument or objects have fallen on it.
oIf the instrument does not operate normally despite having followed the
operating instructions.
oIf the instrument has been damaged in any way.
oIf the instrument operates in a different way to usual.
6.1 Frequent problems
PROBLEM CAUSE POSSIBLE SOLUTION
The Display is lit but no images
are displayed.
1. The connector is slow Check the connection with
the probe
2. The camera has no light Clean the camera
The instrument is switched on for
a short time and the LED light
does not reach the maximum
level of light and/or the display
changes from black to white
and/or the display turns off by
itself.
Battery almost dead Replace the battery.
The instrument does not turn on. Battery is dead Replace the battery