1. System Overview
The Fidelis Collector is the security analytics database for Fidelis Network. The Fidelis Collector receives network
metadata from Fidelis Network sensors (e.g., Direct, Internal, Mail and Web Sensors) and stores it for ongoing
analysis. A Fidelis Collector cluster of appliances consist of one or two Collector Controller(s) and typically three or
more Collector XA database nodes.
Figure 1: Fidelis Network — Collector Controller 10G (Rev-J)
Figure 2: Fidelis Network — Collector XA4 Appliance (Rev-J)
2. Documentation & References
Fidelis Network product documentation, appliance specifications, and instructions can be found at
https://support.fidelissecurity.com or through the icon in the CommandPost/K2 user interface.
Appliance Default Passwords
System
Account
Default Password
SSH / Appliance Console
fidelis
fidelispass
CommandPost/K2 User Interface
admin
system
iLO
administrator
(printed on label, top of server)
Technical Support
For all technical support related to this product, check with your site administrator to determine
support contract details. For support of your product, contact your reseller. If you have a direct
support contract with Fidelis Cybersecurity, contact the Fidelis Cybersecurity support team at:
• Phone: +1 301.652.7190
• Toll-free in the US: 1.800.652.4020 – Use the customer support option.
• Email: [email protected]
• Web: https://support.fidelissecurity.com

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
3
Collector Setup Checklist
Check
Fidelis Network Sensor – Appliance Requirements
Appropriate rack space, power, and cooling (Appendix B)
Rack tools, rails, and connectors
Keyboard and video monitor / KVM switch for temporary appliance setup
Power cables — two per appliance, appropriate for power source and region
Ethernet cables (cat5 and optical) for Admin, DB, SYNC and iLO ports (Section 3)
Network switches with enough physical ports (Section 4)
Optical transceivers for switches
Logical network information: IP addresses, hostnames (Section 5, Appendix A)
For Fidelis Network Software version 9.3.3 and later, the appliance system type (Appendix C)
3. Collector: Network Port and Cabling Requirements
Each appliance must be connected to the various networks with appropriate cables and in some
cases, transceivers. The tables below describe the physical connection and cable type associated
with each port on the appliance.
Collector Controller 10G Appliance
Port Label
Physical Connection Type (default)
Cable Type
Admin
10GbE LC connector
Fiber SR Patch Cable, Multimode 850nM
DB Net
10GbE LC connector
Fiber SR Patch Cable, Multimode 850nM
ILO
GbE RJ45 (copper)
Cat 5/5e/6 patch cable
Figure 3: Network Port Assignments — Collector Controller 10G (Rev-J)

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
4
Collector XA4 Database Node
Port Label
Physical Connection Type (default)
Cable Type
Admin
GbE RJ45 (copper)
Cat 5 patch cable
DB Net
10GbE SFP+ w/ LC Connector
Fiber SR Patch Cable, Multimode 850nM
SYNC net
10GbE SFP+ w/ LC Connector
Fiber SR Patch Cable, Multimode 850nM
ILO
GbE RJ45 (copper)
Cat 5 patch cable
Figure 4: Network Port Assignments — Collector XA4 (Rev-J)
4. Collector Networking Environment
The Collector appliances use multiple networks for service and inter-node communication. You can
deploy networks as:
• Three independent physical switches, or
• Multiple independent VLANs on the same switch fabric
The ADMIN, DB, and SYNC switches or VLANs must be different broadcast domains. iLO and
Admin networks may intersect.
Use the tables below to identify the count and type of switch ports necessary to support the number
of appliances for your deployment.
Admin Network
The Admin Network connects the Collector Controller to the Fidelis Network sensors and
CommandPost/K2 systems. Also connects the Collector XA nodes to the CommandPost/K2.
Appliance
Switch Port Type
Qty.
Collector Controller 10G
10GbE Fiber SR, LC connector (may require SFP+ transceiver)
1
Collector XA4
GbE - Copper Cat5 RJ45 port
1

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
5
DB Network
The DB Network allows communication between Collector Controller and Controller XA nodes. This
network must be independent from other networks. IPv4 addressing only.
Appliance
Switch Port Type
Qty.
Collector Controller 10G
10GbE Fiber SR, LC connector (may require SFP+ transceiver)
1
Collector XA4
10GbE Fiber SR, LC connector (may require SFP+ transceiver)
1
SYNC Network
The SYNC Network provides transport for database node synchronization. This network must be
independent from other networks. Only IPv4 addresses are supported.
Appliance
Switch Port Type
Qty.
Collector Controller 10G
n/a
Collector XA4
10GbE Fiber SR, LC connector (may require SFP+ transceiver)
1
iLO / IPMI Network
Optional network for remote/out-of-band server administration.
Appliance
Switch Port Type
Qty.
Collector Controller 10G
GbE - Copper Cat5 RJ45 port
1
Collector XA4
GbE - Copper Cat5 RJ45 port
1
5. Appliance — Logical Network Configuration
Each physical connection must be assigned logical network information. Build a table of the logical
information for each appliance (sample below) that you can reference during configuration. You will
refer to this table multiple times during setup. Appendix A has a worksheet you may use.

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
6
Sample Network Configuration Table
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
SYNC/eth2
iLO/IPMI
Hostname (FQDN)
collector-
xa1.organization.net
Static IP Address
10.1.2.3
192.168.1.3
172.16.1.3
10.2.3.3
Subnet Mask
255.255.255.0
255.255.255.0
255.255.255.0
255.255.255.0
Gateway
10.1.2.1
10.2.3.1
Proxy Server
10.5.6.7
DNS Servers
8.8.4.4, 8.8.8.8
NTP Servers
pool.ntp.org
Time Zone
UTC (+0)
6. Appliance Installation
Rack Installation
Install each appliance in an enclosure/location that has necessary power and cooling.
Power
Connect power cables to the power supplies in the back of the appliance.

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
7
Network Cabling
Using the connectors and cables described in sections 3 and 4, begin to connect the appliances to
the networks. Refer to the Collector Network Diagram below.
To cable the Collector Controller 10G appliance(s) to the switches:
1. Connect the Admin (eth0) port to the “ADMIN” switch port.
2. Connect the DB (eth1) port to the “DB” switch port
3. Optionally, connect the iLO port to the ADMIN (or iLO) switch port.
4. Repeat for each Collector Controller.
To cable the Collector XA4 Node appliances to the switches:
1. Connect the Admin (eth0) port to the “ADMIN” switch port.
2. Connect the DB (eth1) port to the “DB” switch port.
3. Connect the SYNC (eth2) port to the “SYNC” switch port.
4. Optionally, connect the iLO port to the ADMIN (or iLO) switch port.
5. Repeat for each Collector XA.
Figure 5: Collector Network Diagram

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
8
7. Appliance Network Configuration
1. Power on the appliance(s).
2. Connect to the component CLI using one of the following methods:
- Via KVM Console: Connect a keyboard
and monitor to the appliance.
- For Fidelis Network appliances version
9.3.3 or later, the screen on the right is
displayed:
3. If you see the screen above, perform the following steps to apply the software. Otherwise
skip to step 4.
a. With Perform Initial Install or Factory Reset selected, press Enter.
b. Use the Up and Down arrow keys to select
the system type Collector Controller (or
Collector XA for cluster), and press Enter.
If you need help determining the system
type, see Appendix C.
The system displays a screen with the
message “Congratulations, your CentOS
installation is complete.”
4. Login to the appliance using console
5. Use these credentials at the login prompt. You will be required to change the password
immediately:
- user: fidelis
- default password: fidelispass
6. Change to root using the default password
7. From the command line, run
/bin/bpctl_start
/bin/bypass_util all set_force_bypass off
8. Run the following to start the Fidelis Setup program:
/FSS/bin/setup
9. Within Setup, select Network Settings.

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
9
10. Configure the network parameters for the system and each active network interface.
• Use the Network Configuration table you prepared earlier.
• When complete, return to the top menu.
11. When complete, select OK to leave Setup.
12. From command line, reboot the system:
sudo /fss/bin/shutdown.pl --user admin –reboot
13. Repeat steps for all appliances being added to the Collector cluster
14. Use the PING command to verify connectivity between the XAs on their SYNC/eth2
interfaces.
8. Cluster Setup
On the Final Collector XA4 Appliance
If you have not completed setup for the XA4 appliances in section 7 above, or you are adding an
XA4 appliance to the Collector, follow these steps:
1. Login via KVM console.
2. Use these credentials at the login prompt. You will be required to change the password
immediately:
- user: fidelis
- default password: fidelispass
2. Change to root using the default password
3. From the command line, run
/bin/bpctl_start
/bin/bypass_util all set_force_bypass off
4. From the command line, run: /FSS/bin/setup
5. Navigate to Collector Settings.
6. At the XA4 count, enter the number of XA4 appliances, and select Ok.
7. Review the list of IP addresses. Select Confirm if these are correct or select Edit to correct
them.

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
10
9. Fidelis Network Integration
Register Collector Controller 10G with CommandPost/K2
1. Log into the CommandPost/K2 user interface from a web browser.
2. Navigate to System > Components.
3. Click Add Component.
4. Fill in the Add New Component form:
Component Type
Specify Collector.
Component Name
Specify a “friendly” name for the Collector. This is not
the fully qualified domain name of the Controller.
Component IP Address
Specify the IP address of the primary Collector
Controller 10G appliance
Description
(optional) Specify a description, for example location,
business unit, etc.
5. Click Save
6. Register the Collector to the CommandPost/K2. Click Register and accept the End User
License Agreement (EULA).
CommandPost/K2 will then communicate with the Collector at the specified IP address.
Register Collector Controller 10Gs with the Fidelis Sensors
1. Log into the CommandPost/K2 user interface from a web browser.
2. Navigate to System > Components
3. Select the appropriate Direct, Internal, Mail, or Web sensor to expand its details and then
click Config.
4. In the left navigation, select the appropriate item for the sensor Direct, Internal, or Mail.
5. Click the Advanced or Metadata tab for the sensor.
6. In the Send metadata to collector list, select the Collector from the list.
7. Repeat for each Fidelis sensor.

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
11
Appendix A: Network Configuration Worksheet
Collector Controller 10G (Primary)
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
iLO/IPMI
Hostname (FQDN)
Static IP Address
Subnet Mask
Gateway
Proxy Server
DNS Servers
NTP Servers
Time Zone
Collector Controller 10G (Failover)
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
iLO/IPMI
Hostname (FQDN)
Static IP Address
Subnet Mask
Gateway
Proxy Server
DNS Servers
NTP Servers
Time Zone

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
12
Collector XA4 (A)
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
SYNC/eth2
iLO/IPMI
Hostname (FQDN)
Static IP Address
Subnet Mask
Gateway
Proxy Server
DNS Servers
NTP Servers
Time Zone
Collector XA4 (B)
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
SYNC/eth2
iLO/IPMI
Hostname (FQDN)
Static IP Address
Subnet Mask
Gateway
Proxy Server
DNS Servers
NTP Servers
Time Zone

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
13
Collector XA4 (C)
Network Setting
Assignments
Interface
Admin/eth0
DB/eth1
SYNC/eth2
iLO/IPMI
Hostname (FQDN)
Static IP Address
Subnet Mask
Gateway
Proxy Server
DNS Servers
NTP Servers
Time Zone
Appendix B: System Specifications
Collector Controller 10G
Collector XA4
Form Factor
1U rack-mount chassis
SFF
2U rack-mount chassis
SFF
CPU
Dual Intel Xeon Gold 6248
20/40-core 2.5 Ghz
Dual Intel Xeon Gold 6246
12/24-core 3.3 Ghz
Memory
128 GB
ECC DDR4 2933Mhz
192 GB
ECC DDR4 2933Mhz
Storage Capacity &
Configuration
300 GB
2x HD, RAID-1
300 GB
2x HDD, RAID-1
------------------------
1.2 TB
22x HDD, RAID-10 (13.2TB)
Network Adapters
4x 1GbE
2x 10GbE optical
4x 1GbE
2x 10GbE optical
Out of Band Management
Integrated Lights Out Management (ILO)
Integrated Lights Out Management (ILO)
Dimensions
H: 4.29 cm (1.69 in)
W: 43.46 cm (17.11 in)
D: 70.7 cm (27.83 in)
H: 8.73 cm (3.44 in)
W: 44.54 cm (17.54 in)
D: 67.94 cm (26.75 in)
Weight (appx.)
16.27 kg (35.86 lb)
24.5 kg (54 lb)
Power Supply
Dual hot-swap
800W High Efficiency AC power supplies
Dual hot-swap
800W High Efficiency AC power supplies
Operating Temperature
10° to 35°C (50° to
95°F) at sea level
10° to 35°C (50° to
95°F) at sea level

QUICK START GUIDE
Fidelis Network® High Capacity Collector
www.fidelissecurity.com ©Fidelis Cybersecurity
14
Appendix C: System Types
For Fidelis Network Software version 9.3.3 and later, the table below shows the software to apply
based on the appliance SKU. You can find the SKU in the following locations:
(Note that the SKU starts with “FSS” and “FNH”.)
• Appliance lid UID decal (see sample on right)
• Shipping carton UID decal (see sample on right)
• Packing list
• Purchase Order
Appliance SKU with:
System Type
FSS-CXA4-J
FNH-CXA4-J
Collector XA
FSS-CC10G-J
FNH-CC10G-J
Collector Controller
QSC_Fidelis_CHC_Rev-J_20200716
This manual suits for next models
8
Table of contents
Other Fidelis Network Hardware manuals

Fidelis
Fidelis FDH-3000 User manual

Fidelis
Fidelis Network Collector SA Rev-1 Series User manual

Fidelis
Fidelis Common Criteria User manual

Fidelis
Fidelis Network CommandPost User manual

Fidelis
Fidelis Network Collector SA User manual

Fidelis
Fidelis CommandPost+ User manual

Fidelis
Fidelis Deception Decoy Server FDH-1000-C User manual
Popular Network Hardware manuals by other brands

ZyXEL Communications
ZyXEL Communications NSA-220 Series quick start guide

DSE
DSE DN Series installation manual

Sencore
Sencore ARD 3100 quick start guide

Jusan
Jusan Fonomail ProAttendant Installation and programming manual

SIGMA TEK
SIGMA TEK FDD Power Installation Guide

Streamax
Streamax A5-H0404MNVR user manual