manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Fieldpiece
  6. •
  7. Measuring Instrument
  8. •
  9. Fieldpiece EH4W User manual

Fieldpiece EH4W User manual

01 03 0602 0504
07 09 1208 1110
Quick Start
Wireless Operation
1. Select DC or AC switch position,
depending on accessory head.
2. Select RECV or SEND, depending
on operation you want to perform.
3. Hold SYNC for one second. Search
pattern will initiate on display while
searching for partner device.
4. Set partner device to appropriate
switch position.
5. Hold SYNC on partner device for
onesecond.Signalbarsandbattery
infoofpartner devicewilldisplayon
EH4W when connection is made.
6. Enjoy the wireless goodness!
Certications
C-Tick (N22675)
CE EN 61326-1
FCC
WEEE
RoHS compliant
Description
As a new owner of EH4W you can
now wirelessly receive measurements
from anywhere on the jobsite and be
free from tangled wires. Your EH4W
can be set up to send you indoor
wet bulb measurements over-the-
air for real-time target superheat
calculations while you are outside at
the condenser taking actual superheat
readings.
Take measurements in multiple
places at once and have them sent
wirelessly to you anywhere you are
on the jobsite.
Your EH4W can wirelessly receive
measurements from any Fielpiece
transmitters and display the readings
wherever you are on the job.
EH4W also converts any Fieldpiece
accessory head into a wireless
transmitter to send your measurement
over-the-air to a Fieldpiece wireless
receiver like the HG3, LT17AW, or
EH4W. This allows you to set up your
accessory heads and monitor your
measurements from anywhere on
the jobsite.
Your EH4W easily syncs with
compatible wireless Fieldpiece
transmitters and receivers. EH4W has
a wide wireless range to cover the
whole jobsite.
Fieldpiece
Wireless Electronic
Accessory Head
Handle
OPERATOR'S
MANUAL
Model EH4W
Specications
Wireless range: Up to 75 feet (23m) line of sight
MinimumWirelessDistance: Upto1foot(30cm)
Wireless Frequency: 910MHz to 920MHz (US),
868.1MHz to 868.5MHz (European)
Display: 5000 count FSTN LCD
MeasurementRate:2.5timespersecond,nominal
Overrange: (OL) or (-OL) is displayed
Accuracy:Statedat 73oF±9oF(23°C±5°C),<75%RH
Temperature Coecient: 0.1 x (specied ac-
curacy) per °C [0°C to 19°C (32°F to 66°F), 28°C
to 50°C (82 °F to 122°F)]
Auto Power O: Approx. 30 minutes
Low battery indicators: An empty battery icon
on LCD will indicate when batteries must
be replaced. Battery in lower left is for EH4W.
Battery in upper right is for partner device.
Power: Single standard9-volt battery,NEDA1604,
JIS 006P, IEC 6F22
Battery life: 200 hrs typical with alkaline
Operatingenviroment:32oFto122oF(0°Cto50°C)
at <70% relative humidity
Storage temperature: -4oF to 140oF (-20°C to
60°C), 0 to 80% RH (with battery removed)
Dimensions:140mm(H)x59.2mm(W)x33mm(D)
Weight: Approx. 125g including battery
Safety: Designed to meet CE-EMC.
DC Volts:
Ranges: 500mV, 5000mV (Auto)
Resolution: 0.1mV (500mV), 1mV (5000mV)
Accuracy: ±(0.5%rdg + 3dgts)
Input Impedance: 1MΩ
Input protection: Max 30 VDC or 24VAC rms
AC Volts (50Hz - 500Hz)
Ranges: 500mV, 5000mV (Auto)
Resolution: 0.1mV (500mV), 1mV (5000mV)
Accuracy: ±(1.2%rdg + 6dgts), 50Hz-100Hz
±(1.5%rdg + 6dgts), 100Hz-500Hz
Input Impedance: 1MΩ
Input protection: Max 30 VDC or 24VAC rms
Safety Symbols Used
Caution, refer to manual.
Ground
Double Insulation
How to Use
Normal Display Mode
1. Connect any Fieldpiece accessory
head to EH4W.
2. Select DC switch position for all
accessory heads expect the ACH4
current clamp (AC).
3. Select SEND switch position.
Transmitter Mode
EH4W
1. Connect any Fieldpiece accessory
head to the EH4W by sliding it onto
the top of the handle.
2. Select AC switch position for ACH4
current clamp or DC for all other
accessory heads.
3. Hold the RANGE (SYNC) button for
one second.
Note: Search pattern on LCD will initi-
ate. Once a connection is made, the
signal bars will stay solid represent-
ing signal strength.
Note: The signal strength and battery
condition of the EH4W will be dis-
played on the receiver LCD when a
connection is made.
Note: If no signal is found within two
minutes, EH4W will turn o.
Receiver (LT17AW, EH4W, HG3)
4. Select RECV switch position. Hold
SYNC button for one second. For
HG3,highlightthe test lineandhold
SYNC button for one second.
Note: If no signal is found in two min-
utes, NSG will display. Press SYNC
button for one second to re-sync.
Receiving Mode
EH4W
1.Select RECV switch position. Then
Hold RANGE (SYNC) button until
it beeps.
Note: If no signal is found within two
minutes, EH4W will stop search-
ing. Once connection is made, the
signal strength and battery life of
thepartner device will be displayed
on EH4W.
Transmitter (ET2W)
1. Connect any Fieldpiece accessory
head.
2. Select AC switch position for ACH4
or DC for all other accessory heads.
3. Hold SYNC button for one second.
Transmitter (EH4W)
1. Connect any Fieldpiece accessory
head.
2. Select SEND switch position. Hold
RANGE button until beeps to sync.
Transmitter (LT17AW)
1. Select the desired measurement
range on the dial.
2. Hold SYNC button for one second.
Auto-Connection
The above operations are to
synchronize wireless devices for the
rst time. When powered on, EH4W
will automatically connect to the
last single-link receiver (LT17AW,
ET2W, or EH4W) or transmitter it was
sychronized to. No need to constantly
sync the same pair.
Data Hold, Max, Min
Data Hold, Max, and Min are only
used when EH4W is in SEND switch
position. Data Hold, Max, and Min are
disabled in RECV switch position.
1. Press HOLD/MAX/MIN to freeze the
current reading on the display.
2. Press HOLD/MAX/MIN again to
show the highest (MAX) reading.
Press HOLD/MAX/MIN a third time
to show the lowest (MIN) reading.
3. Pressing HOLD/MAX/MIN will cycle
throughthesesettingsintheabove
order.
4. Hold the HOLD/MAX/MIN button
for one second to exit and return
to real-time display.
Auto Power O
Auto Power O (APO) is automati-
cally disabled when EH4W is wirelessly
connected to a partner device. APO
can be manually disabled by holding
the HOLD/MAX/MIN button while
turning the switch from OFF to any
other switch position.
Maintenance
Clean the exterior with a dry cloth.
Do not use liquid.
Battery Replacement
The battery on the EH4W must be
replaced when the lower left battery
icon( ) is empty. At this point, the
EH4W will display "bAtt" on the screen
accompanied by a continuous beep.
The meter will turn o in 5 seconds
and no further measurement will be
allowed until the battery is replaced.
More Wireless...
Easily add to your wireless arsenal
any Fieldpiece accessory head with
ET2W transmitters. HG3 Multi-Channel
Wireless Analyzer receives wireless
readings from multiple transmitters.
MAX 30VDC
24VAC
CONNECT ONLY TO
ACCESSORY HEAD!
PRESS FOR 1 SEC TO EXIT
AUTO-OFF
SEND ONLY
EH4W
DC AC
CAT.III
300V
400A
CLAMP
ACH4
AC Current
Clamp
1AAC / 1mVAC
400AAC MAX
!
ET2W
LO BATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LO BATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LO BATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
AUTO OFF
ARH4
ET2W w/ ARH4
transmitting wirelessly
to EH4W
MAX 30VDC
24VAC
CONNECT ONLY TO
ACCESSORY HEAD!
PRESSFOR 1 SEC TO EXIT
AUTO-OFF
SENDONLY
EH4W
DC AC
!
!
WARNINGS
!
Use only with Fieldpieceaccessory heads. Accessory
heads deliver low voltage (under 2V) to the EH4W.
Voltages higher than 30VDC or 24VAC rms can damage
the EH4W.
DO NOT CONNECT EH4W TO LINE VOLTAGE!
CAT.III
300V
400A
CLAMP
ACH4
AC Current
Clamp
1AAC/ 1mVAC
400AACMAX
!
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
AUTOOFF
ARH4
ET2W
with ARH4
ET2W
with ACH4 ET2W
with ACM3
Clear
Input Output
Recall
Enter
Save
Sync
SETUP
Target
Evaporator
Logger
Light
ExitTemp
CFM
Display
Superheat
SubcoolingCombustion
HVAC Guide
CheckMe!
Fieldpiece
HG3
Data
Service
Displa
y
INPUT FORM
SET 01
Set ID:Indoor Temp
Measurement: 72.8
SET 02
SET ID:Comp Amps
Measurement: 23.6
CustomerID:__JONES123
HG3 Multi-Channel
Wireless Receiver
data logging
multiple readings at
the same time
13 15 1814 1716
19 21 2420 2322
Limited Warranty
In the USA, this meter is warranted
against defects in material or
workmanship for one year from date
of purchase. Fieldpiece will replace or
repair the defective unit, at its option,
subject to verication of the defect.
This warranty does not apply
to defects resulting from abuse,
neglect, accident, unauthorized
repair, alteration, or unreasonable use
of the instrument.
Any implied warranties arising
from the sale of a Fieldpiece product,
including but not limited to implied
warranties of merchantability and
tness for a particular purpose, are
limited to the above. Fieldpiece shall
not be liable for loss of use of the
instrument or other incidental or
consequential damages, expenses, or
economic loss, or for any claim of such
damage, expenses, or economic loss.
State laws vary. The above
limitations or exclusions may not
apply to you.
For Service
In the USA, call Fieldpiece
Instruments for one-price-x-all out of
warranty service pricing. Send check or
money order for the amount quoted.
Send the meter freight prepaid to
Fieldpiece Instruments. Send proof
of date and location of purchase for
in-warranty service. The meter will be
repaired or replaced, at the option of
Fieldpiece, and returned via least cost
transportation. Outside of the USA,
please visit www.eldpiece.com for
service contact information.
www.fieldpiece.com
© Fieldpiece Instruments, Inc 2011; v11
More Fieldpiece
for HVAC
Compatible Wireless Tools
Fieldpiece offers other wireless
solutions to further eliminate awkward
wires and cables.
SRS2C Wireless Scale
SRS2C is the only wireless refrigerant
scale in the HVAC industry.
SMAN3 Digital Manifold
SMAN3 is the most advanced digital
manifold w/ micron gauge on the
market. Check it out.
Refrigerant Leak Dectectors
SRL2 IR Refrigeant leak dectector
is advanced technology in your hand
to pinpoint those tough leaks. SRL8
Headed-Diode Refrigerant leak detector
is method you know, but packed with
more features.
ET2W w/ ACM3
transmitting
wirelessly to HG3
Clear
Input Output
Recall
Enter
Save
Sync
SETUP
Target
Evaporator
Logger
Light
Exit Temp
CFM
Display
Superheat
SubcoolingCombustion
HVAC Guide
CheckMe!
Fieldpiece
HG3
Data
Service
Displa
y
INPUT FORM
SET 01
Set ID:Indoor Temp
Measurement: 72.8
SET 02
SET ID:Comp Amps
Measurement: 23.6
CustomerID:__JONES123
CAT.III
300V
400A
CLAMP
ACH4
AC Current
Clamp
1AAC/ 1mVA C
400AACMAX
!
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
ET2W
LOBATT
SEND
RECEIVE
ON
AC
DC
Wireless
Transmitter
SYNC
AUTOOFF
ARH4
Clear
Input Output
Recall
Enter
Save
Sync
SETUP
Target
Evaporator
Logger
Light
Exit Temp
CFM
Display
Superheat
SubcoolingCombustion
HVAC Guide
CheckMe!
Fieldpiece HG3
Data
Service
Displa
y
INPUT FORM
SET 01
Set ID:Indoor Temp
Measurement: 72.8
SET 02
SET ID:Comp Amps
Measurement: 23.6
CustomerID:__JONES123
HG3 w/ Multi-
Channel
Wireless
FUSED
200mA
MAX
FUSED
30V
MAX
WIRELESS
ENABLED
MAX/MIN
SYNCHOLD
CAT.III
MAX
600V
15 SEC FOR 500mV
RANGE
AUTO-OFF
500
600600 50
5000m
500m
500µ
50m
200m
200m
500m
5000m
50m
50 500
500µ
500
750
500
1400
200
2
K
200
20
M
2
K
200
K
20
RECV
LT17AW w/ Built-in Wireless
PRESSFOR1 SECOND
AUTO-OFF
SRS2
Wireless
Refrigerant
Scale
ZERO
SYNC
UNITS
ON/OFF
PRESSFOR
1SECOND
T1 T2
Atmospheric
Pressure
Superheat
Subcooling
T1T2 Direct Saturation
Target
Superheat
CALCAL
CAL CAL
Test
Pressure
AUTO
OFF
Refrigerant ON/OFF
Enter
Units
Alarm
Digital Manifold + Vacuum Gauge
SMAN3
ODDB
HH:MM:SS
Psig
Kpa
inHg
cmHg
Psig
Kpa
inHg
cmHg
SHT1
VSAT
APO
Microns
HiLo
SetStable
Alarm
IDWB
Target SH
R-
°F°C
SCT2
LSAT
°F°C
°F°C
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
T2
PEAK
MUTE
ON/OFF
ON/OFF
L/M/H
SENSITIVITY
H
M
L
PEAK
LOW-BATT
PRESSFOR
1SECOND
SRL2
Infrared
Refrigerant
Leak Detector
SENSITIVITY
H
M
L
AUTO-ZERO
LOW-BATT
SRL8
ON/OFFMUTE
ZEROL/M/H
Heated Diode
Refrigerant
Leak Detector
PRESSFOR
1SECOND
BATTERY
CHECK

Other Fieldpiece Measuring Instrument manuals

Fieldpiece ASH3 User manual

Fieldpiece

Fieldpiece ASH3 User manual

Fieldpiece HVAC Guide HG1 User manual

Fieldpiece

Fieldpiece HVAC Guide HG1 User manual

Fieldpiece CAT45K2 User manual

Fieldpiece

Fieldpiece CAT45K2 User manual

Fieldpiece STA2 User manual

Fieldpiece

Fieldpiece STA2 User manual

Fieldpiece HS32 User manual

Fieldpiece

Fieldpiece HS32 User manual

Fieldpiece ACM3 User manual

Fieldpiece

Fieldpiece ACM3 User manual

Fieldpiece CAT85K2 User manual

Fieldpiece

Fieldpiece CAT85K2 User manual

Fieldpiece SRL8 User manual

Fieldpiece

Fieldpiece SRL8 User manual

Fieldpiece DDSM1 User manual

Fieldpiece

Fieldpiece DDSM1 User manual

Fieldpiece SC54 User manual

Fieldpiece

Fieldpiece SC54 User manual

Fieldpiece SMG5 User manual

Fieldpiece

Fieldpiece SMG5 User manual

Fieldpiece SMG5 User manual

Fieldpiece

Fieldpiece SMG5 User manual

Fieldpiece JL3PR User manual

Fieldpiece

Fieldpiece JL3PR User manual

Fieldpiece SVG3 User manual

Fieldpiece

Fieldpiece SVG3 User manual

Fieldpiece ACH User manual

Fieldpiece

Fieldpiece ACH User manual

Fieldpiece SC57 User manual

Fieldpiece

Fieldpiece SC57 User manual

Fieldpiece SDMN6 User manual

Fieldpiece

Fieldpiece SDMN6 User manual

Fieldpiece SC640 User manual

Fieldpiece

Fieldpiece SC640 User manual

Fieldpiece CAT85 User manual

Fieldpiece

Fieldpiece CAT85 User manual

Fieldpiece SC66 User manual

Fieldpiece

Fieldpiece SC66 User manual

Fieldpiece AMN2 User manual

Fieldpiece

Fieldpiece AMN2 User manual

Fieldpiece SMG5 User manual

Fieldpiece

Fieldpiece SMG5 User manual

Fieldpiece AAT3 User manual

Fieldpiece

Fieldpiece AAT3 User manual

Fieldpiece SC44 User manual

Fieldpiece

Fieldpiece SC44 User manual

Popular Measuring Instrument manuals by other brands

Vernier Go Direct GDX-RAD manual

Vernier

Vernier Go Direct GDX-RAD manual

Envertech EVB300 User's operating manual

Envertech

Envertech EVB300 User's operating manual

Wagner Electronics L610 owner's manual

Wagner Electronics

Wagner Electronics L610 owner's manual

hecht 2003 TRANSLATION OF ORIGINAL INSTRUCTIONS FOR USE

hecht

hecht 2003 TRANSLATION OF ORIGINAL INSTRUCTIONS FOR USE

Gossen MetraWatt LonWorks ENERGYMID U228 W1 Series Interface description

Gossen MetraWatt

Gossen MetraWatt LonWorks ENERGYMID U228 W1 Series Interface description

Bender ISOMETER iso1685DP-425 manual

Bender

Bender ISOMETER iso1685DP-425 manual

ELMACRON 1005RE instructions

ELMACRON

ELMACRON 1005RE instructions

Mecmesin Compact Force Gauge operating manual

Mecmesin

Mecmesin Compact Force Gauge operating manual

TAG Heuer POCKET PRO user manual

TAG Heuer

TAG Heuer POCKET PRO user manual

GLI International P33 Operating instructions manual

GLI International

GLI International P33 Operating instructions manual

Elite Element DCM-120100C instruction manual

Elite Element

Elite Element DCM-120100C instruction manual

FRER C15WPM100 operating manual

FRER

FRER C15WPM100 operating manual

Redback Q 2007 operating manual

Redback

Redback Q 2007 operating manual

Panasonic LC2H preset Specifications

Panasonic

Panasonic LC2H preset Specifications

Beta 680 Instructions for use

Beta

Beta 680 Instructions for use

Thingy AQ quick start guide

Thingy

Thingy AQ quick start guide

Agilent Technologies 4291B Operation manual

Agilent Technologies

Agilent Technologies 4291B Operation manual

Rohde & Schwarz CMW-KM75 Series user manual

Rohde & Schwarz

Rohde & Schwarz CMW-KM75 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.