1 Connection for hoses
2 Main filter
3 Fan
4 Power intake with main circuit-breaker
5Top
6 Housing
7 Knobs to lock the top
8 Control panel
Function
MG100S is a filter unit for cleaning of both particles and gases. The unit is to be used at
filtration of process air from soldering, glueing, cleaning, printing processes etcetera.
MG100S is designed to be connected to two suction arms, Ø 60 mm, but can also be
connected to other types of nozzles, for example a smaller suction cabinette. MG100S
complies with the ESD demands.
MG100S is equipped with filter surveillance.
Installation
MG100S is delivered with 2 m main cable.
On the rating plate, which is placed at the bottom of the unit, you find information about type
and size of the fuses.
The MG100S can easily be hung up on for example a work bench, by completing the unit
with a hanging device, Art.No. 780-3001-ESD. (Can be ordered separately.)
NOTE! The unit must not be exposed to temperatures exceeding 50° Celsius, open
flames or condensated solvents.
Putting into service
Connect the unit to a 1-phase wall socket and switch on the main circuit breaker. (NOTE!
there could come out some dust from the main filter after transportation, so make sure that
the starting of the unit is made in an appropriate room.)
Control panel
MG100S is equipped with a micro processor-based function- and filter surveillance sys-
tem. An alarm can be indicated with a red light-emitting diode together with a buzzer. There
are two alarm functions:
Red light-emitting diode twinkles: Whentherecommendeduptimeof the filter is exceeded.
Measure: Clean suction nozzle and tubes and change the main filter.
Red light-emitting diode is shining: When suction capacity is low.
Measure: Check suction nozzles and tubes, clean if necessary. If the alarm comes back
when starting, change the main filter.
Reset
Receipt of alarm is made with the button of the control panel. When changing the main filter,
the filter uptime is set to zero by keeping the button pressed and turning the switch on at the
same time.
Maintenance and replacement of filter
The main filter should be changed by alarm, minimum once a year. Check hoses and
nozzles, clean if necessary. If the suction is deficient after cleaning, change the main filter.
When changing the main filter, turn off the unit with the switch and loosen the top with the 4
knobs on the short sides of the unit. Lift the top straight up and put it aside (if necessary
loosen the hoses). Pull the main filter straight up. A new filter is re-assembled in the reverse
order, with the text on the filter upwards. Make sure that the inlet to thefanfitstotheconnection
in the bottom of the filter and that the new filter has the right side up.
NOTE! The new filter has to be marked with the date of change.
When a new main filter is mounted, mark the filter with the date of the filter exchange.
OPERATING INSTRUCTIONS MG100S OPERATING INSTRUCTIONSMG100S