15436 1 l 1
PROTECT YOUR RO-FILTER
• Remember to maintain your
RO-Filter when it is not in use,
right now when it is stored in
winter.
• Simple and quickly done with
the RO-Membrane
Maintenance.
To protect the membrane, proceed as follows:
1. Switch off the HydroPower RO and
disconnect the power supply.
2. Drain the water from the HydroPower RO.
Unscrew all filter top caps and open the
pressure relief valve on the back of the
HydroPower RO until no more water leaks
out.
3. Close the pressure relief valve and screw
the yellow cap onto the concentrate outlet.
4. Remove the pre-filter and resin filter
cartridges and store them protected from
dust and dirt.
5. Pour one bottle of membrane care liquid (1l)
into each of the mebrane tanks.
6. Fill all tanks (#1 pre-filter + both
membranes #2, #3) with tap water until all
three tanks have filled just below the top
edge. Tank #4 can remain without water.
7. Close all four tanks.
The membranes are protected and the
HydroPower RO can be stored.
Never expose your RO unit
to frost!
NOTE: The RO-Membrane Maintenance fluid #15436
is only a maintenance fluid, no anti-freeze!
HydroPower RO40C
ROPURE WATER FILTER SYSTEM
Membrane Protection
ROMEMBRANE MAINTENANCE
Part No. Content Pack
The membrane achieves its optimal life
with regular water flow or flushing.
If the HydroPower RO is not in use for an
extended period of time (longer than 7
days), the membrane must be protected
against blockage.
For this purpose, there is the UNGER
Membrane Care Agent (Order No. 15436).
You need one bottle (1l) for each memb-
rane. This preserves the current state of
the membrane and prevents reduced per-
formance and/or damage after sitting for
a longer period of time. Alternatively, you
can run the unit once a week for approx.
30 minutes to rinse the membranes.
Re-commissioning:
1. Unscrew all 4 filter top caps.
2. Drain the water: Unscrew the yellow cap and
assemble the concentrate hose.
Now open the pressure relief valve at the rear.
3. Insert the filters. Pay attention to the correct position (see page 33).
4. Screw the top-caps back on and start the system.
5. The membrane care liquid is automatically rinsed out and the resin
filter is protected by the by-pass process.
No responsibility accepted for accuracy;
subject to change without notice.
www.ungerglobal.com
RO30CRO30G RO60S
TRLR1
1
7
3
4
2
3
4
6
8
9
1
3 4
2
QUICK MANUAL (RO30G, RO30C, RO60S)
• The RO unit should not be shut down
for more than 7 days.
• If the system is shut down for longer,
it has to be maintained.
• Nevertheless, the device should not
be exposed to frost,
because the membrane is protected
only externally.
1. Bridge the resin cartridge.
2. Unscrew the filter cup in the pre-filter
group and remove the filter element.
3. Insert the feed pipe in the black filter.
Transverse hole must be at the bottom.
4. Fill the maintenance fluid into the right
filter cup and firmly attach it again.
5. Connect the system to the water supply.
Both water outputs must remain open.
Make sure the system is switched off!
6. Open the water inlet valve and allow the
inflowing water to flow freely through the
system (No power!)
7. Make sure that the water inlet valve
does not remain open for more than 10
seconds. There is a risk that the entire
maintenance fluid will be completely
flushed out.
To protect the membrane, proceed as follows:
1. Disconnect the water supply if
connected.
2. Connect the concentrate hose so that
excess water can drain.
3. Disconnect the exit hose from the
pre-filter case.
4. Put the hose into the bottle of the
maintenance fluid.
5. Place the bottle securely.
6. Start the pump.
7. The bottle is now quickly sucked
empty.
8. As soon as the bottle is empty,
stop the system
9. Re-connect the hose to the
pre-filter case.
Re-commissioning:
1. Disconnect the concentrate and
the hose from the bottom of the
DI filter.
2. Lead the hoses into a bucket.
3. Connect the tab water line.
• Start the Pump at the control box.
• Press the buttons until you read
FIL in the display.
• The pump flushes the membrane.
4. Now the water is flushed into the bucket.
Let it run for at least 30 minutes to
asure that no maintenance fluid is in
the system. Reconnect the hose to the
system like in picture 1.
HiFlo RO30G, RO30C, RO60S HydroPower RO XXL (Trailer)
ROPURE WATER FILTER SYSTEM
Membrane Protection

This manual suits for next models

5

Other unGer Water Filtration System manuals

unGer HiFlo RO-Mobil Manual

unGer

unGer HiFlo RO-Mobil Manual

unGer HiFlo Ro-Moobil RO30G Manual

unGer

unGer HiFlo Ro-Moobil RO30G Manual

unGer Hydro Power Ultra DIUH1 User manual

unGer

unGer Hydro Power Ultra DIUH1 User manual

unGer RO60C User manual

unGer

unGer RO60C User manual

unGer HydroPower RO35C User manual

unGer

unGer HydroPower RO35C User manual

unGer HYDRO POWER ULTRA User manual

unGer

unGer HYDRO POWER ULTRA User manual

unGer Hydro Power DI12 Series Manual

unGer

unGer Hydro Power DI12 Series Manual

unGer nLite Hydro Power HP06T Manual

unGer

unGer nLite Hydro Power HP06T Manual

unGer nLite Hydro Power User manual

unGer

unGer nLite Hydro Power User manual

Popular Water Filtration System manuals by other brands

Culligan Preferred Series Installation and operation guide

Culligan

Culligan Preferred Series Installation and operation guide

Norman 4300 Series Product service manual

Norman

Norman 4300 Series Product service manual

TLV DC3A instruction manual

TLV

TLV DC3A instruction manual

CleanRooms International SAM MS 3S Series Installation, operation and maintenance instructions

CleanRooms International

CleanRooms International SAM MS 3S Series Installation, operation and maintenance instructions

FILTRON K 1006 Installation instruction

FILTRON

FILTRON K 1006 Installation instruction

AquaLiv AWS-RES Usage & installation instructions

AquaLiv

AquaLiv AWS-RES Usage & installation instructions

JBL CristalProfi i40 manual

JBL

JBL CristalProfi i40 manual

KitchenAid Aquasense filters instructions

KitchenAid

KitchenAid Aquasense filters instructions

Vestergaard LifeStraw PEAK Series user manual

Vestergaard

Vestergaard LifeStraw PEAK Series user manual

Davey AquaReviva DAR20C Installation & operating instructions

Davey

Davey AquaReviva DAR20C Installation & operating instructions

Kenmore 625.384480 owner's manual

Kenmore

Kenmore 625.384480 owner's manual

THORLABS TLV-QFXL user guide

THORLABS

THORLABS TLV-QFXL user guide

Frymaster Portable Filtration System MPF50S Series OPERATING & SERVICE MANUAL

Frymaster

Frymaster Portable Filtration System MPF50S Series OPERATING & SERVICE MANUAL

entegris Chemlock Installation and use manual

entegris

entegris Chemlock Installation and use manual

CALEFFI 5790 Series Installation and commissioning manual

CALEFFI

CALEFFI 5790 Series Installation and commissioning manual

GE GN1S04C Owner's manual and installation

GE

GE GN1S04C Owner's manual and installation

Quooker Scale Control Plus installation guide

Quooker

Quooker Scale Control Plus installation guide

Schaffner EMC General Mounting and Installation Guidelines

Schaffner

Schaffner EMC General Mounting and Installation Guidelines

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.