manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. unGer
  6. •
  7. Water Filtration System
  8. •
  9. unGer HiFlo Ro-Moobil RO30C User manual

unGer HiFlo Ro-Moobil RO30C User manual

www.ungerglobal.com
UNGER Germany GmbH
Piepersberg 
D- Solingen
GERMANY
Tel.: ()  
Fax: ()  
ungereuropeungerglobal.com
UNGER UK Ltd.
 Planetary Ind. Est.
Willenhall, WV XA
UNITED KINGDOM
Tel.: () 
Fax: () 
ungerukungerglobal.com
Facebook“f” Logo CMYK/ .eps Facebook “f ”Logo CMYK/ .eps
15436 1 l 1
PROTECT YOUR RO-FILTER
• Remember to maintain your
RO-Filter when it is not in use,
right now when it is stored in
winter.
• Simple and quickly done with
the RO-Membrane
Maintenance.
To protect the membrane, proceed as follows:
1. Switch off the HydroPower RO and
disconnect the power supply.
2. Drain the water from the HydroPower RO.
Unscrew all filter top caps and open the
pressure relief valve on the back of the
HydroPower RO until no more water leaks
out.
3. Close the pressure relief valve and screw
the yellow cap onto the concentrate outlet.
4. Remove the pre-filter and resin filter
cartridges and store them protected from
dust and dirt.
5. Pour one bottle of membrane care liquid (1l)
into each of the mebrane tanks.
6. Fill all tanks (#1 pre-filter + both
membranes #2, #3) with tap water until all
three tanks have filled just below the top
edge. Tank #4 can remain without water.
7. Close all four tanks.
The membranes are protected and the
HydroPower RO can be stored.
Never expose your RO unit
to frost!
NOTE: The RO-Membrane Maintenance fluid #15436
is only a maintenance fluid, no anti-freeze!
HydroPower RO40C
ROPURE WATER FILTER SYSTEM
Membrane Protection
ROMEMBRANE MAINTENANCE
Part No. Content Pack
The membrane achieves its optimal life
with regular water flow or flushing.
If the HydroPower RO is not in use for an
extended period of time (longer than 7
days), the membrane must be protected
against blockage.
For this purpose, there is the UNGER
Membrane Care Agent (Order No. 15436).
You need one bottle (1l) for each memb-
rane. This preserves the current state of
the membrane and prevents reduced per-
formance and/or damage after sitting for
a longer period of time. Alternatively, you
can run the unit once a week for approx.
30 minutes to rinse the membranes.
Re-commissioning:
1. Unscrew all 4 filter top caps.
2. Drain the water: Unscrew the yellow cap and
assemble the concentrate hose.
Now open the pressure relief valve at the rear.
3. Insert the filters. Pay attention to the correct position (see page 33).
4. Screw the top-caps back on and start the system.
5. The membrane care liquid is automatically rinsed out and the resin
filter is protected by the by-pass process.
No responsibility accepted for accuracy;
subject to change without notice.
www.ungerglobal.com
RO30CRO30G RO60S
TRLR1
1
7
3
4
2
3
4
6
8
9
1
3 4
2
QUICK MANUAL (RO30G, RO30C, RO60S)
• The RO unit should not be shut down
for more than 7 days.
• If the system is shut down for longer,
it has to be maintained.
• Nevertheless, the device should not
be exposed to frost,
because the membrane is protected
only externally.
1. Bridge the resin cartridge.
2. Unscrew the filter cup in the pre-filter
group and remove the filter element.
3. Insert the feed pipe in the black filter.
Transverse hole must be at the bottom.
4. Fill the maintenance fluid into the right
filter cup and firmly attach it again.
5. Connect the system to the water supply.
Both water outputs must remain open.
Make sure the system is switched off!
6. Open the water inlet valve and allow the
inflowing water to flow freely through the
system (No power!)
7. Make sure that the water inlet valve
does not remain open for more than 10
seconds. There is a risk that the entire
maintenance fluid will be completely
flushed out.
To protect the membrane, proceed as follows:
1. Disconnect the water supply if
connected.
2. Connect the concentrate hose so that
excess water can drain.
3. Disconnect the exit hose from the
pre-filter case.
4. Put the hose into the bottle of the
maintenance fluid.
5. Place the bottle securely.
6. Start the pump.
7. The bottle is now quickly sucked
empty.
8. As soon as the bottle is empty,
stop the system
9. Re-connect the hose to the
pre-filter case.
Re-commissioning:
1. Disconnect the concentrate and
the hose from the bottom of the
DI filter.
2. Lead the hoses into a bucket.
3. Connect the tab water line.
• Start the Pump at the control box.
• Press the buttons until you read
FIL in the display.
• The pump flushes the membrane.
4. Now the water is flushed into the bucket.
Let it run for at least 30 minutes to
asure that no maintenance fluid is in
the system. Reconnect the hose to the
system like in picture 1.
HiFlo RO30G, RO30C, RO60S HydroPower RO XXL (Trailer)
ROPURE WATER FILTER SYSTEM
Membrane Protection

This manual suits for next models

5

Other unGer Water Filtration System manuals

unGer HiFlo Ro-Moobil RO30G Manual

unGer

unGer HiFlo Ro-Moobil RO30G Manual

unGer Hydro Power Ultra DIUH1 User manual

unGer

unGer Hydro Power Ultra DIUH1 User manual

unGer HydroPower RO35C User manual

unGer

unGer HydroPower RO35C User manual

unGer HYDRO POWER ULTRA User manual

unGer

unGer HYDRO POWER ULTRA User manual

unGer HiFlo RO-Mobil Manual

unGer

unGer HiFlo RO-Mobil Manual

unGer RO60C User manual

unGer

unGer RO60C User manual

unGer nLite Hydro Power HP06T Manual

unGer

unGer nLite Hydro Power HP06T Manual

unGer Hydro Power DI12 Series Manual

unGer

unGer Hydro Power DI12 Series Manual

unGer nLite Hydro Power User manual

unGer

unGer nLite Hydro Power User manual

Popular Water Filtration System manuals by other brands

HYDRALOOP H300 User & installation manual

HYDRALOOP

HYDRALOOP H300 User & installation manual

FSA H1-EQ5AN manual

FSA

FSA H1-EQ5AN manual

CAB MAESTRO 2M Operator's manual

CAB

CAB MAESTRO 2M Operator's manual

Laica Fast Disk FD03A Instructions and warranty

Laica

Laica Fast Disk FD03A Instructions and warranty

Oase Filtral 2500 UVC operating instructions

Oase

Oase Filtral 2500 UVC operating instructions

Kenmore 625.349223 manual

Kenmore

Kenmore 625.349223 manual

Oase FiltoClear 5000 operating instructions

Oase

Oase FiltoClear 5000 operating instructions

Sharp FZ-S63MF Operation manual

Sharp

Sharp FZ-S63MF Operation manual

Bestway 58515 owner's manual

Bestway

Bestway 58515 owner's manual

DH Instruments 1-2 IN. FILTER KIT instruction sheet

DH Instruments

DH Instruments 1-2 IN. FILTER KIT instruction sheet

Olympus MAJ-2307 instructions

Olympus

Olympus MAJ-2307 instructions

Eureka Forbes AquaSure Aayush user manual

Eureka Forbes

Eureka Forbes AquaSure Aayush user manual

Pentair FRESHPOINT GRO-575M Installation and operation manual

Pentair

Pentair FRESHPOINT GRO-575M Installation and operation manual

Antunes TAC-02 quick start guide

Antunes

Antunes TAC-02 quick start guide

GE GX1S01R installation instructions

GE

GE GX1S01R installation instructions

Filtreco Basic combi drum 25 user manual

Filtreco

Filtreco Basic combi drum 25 user manual

amiad SAF X Series Installation, operation & maintenance instructions

amiad

amiad SAF X Series Installation, operation & maintenance instructions

Hydac MFU-30E Operating and maintenance instructions

Hydac

Hydac MFU-30E Operating and maintenance instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.