Firex 591S User manual

The professional choice in fire safety.
The NEW remote accessories are designed to be used with
Firex duct smoke detectors to provide the most complete
functionality ever available in such a device.
The remote accessory is available with either the single gang
remote indicator/control (591 models), or with the addition of
a single gang strobe assembly (592 models). Both versions
are compatible with standard Decora style cover plates
(choice of white, red or stainless steel). A strobe-only version
(593 models) is available for retrofit upgrade of “controller
only” installations.
The indicator/control assembly provides:
●Visual indication of detector Pilot, Trouble and Alarm
Functions
●Selectable audible indication of Alarm, Trouble or both
●Buzzer Silence function, with silenced indication and
“ringback” following condition correction
●Lamp/Buzzer test function
●Key-Operated detector Test and Reset functions
●Lever-operated “No-Tools” terminal block
●Port for plugging in the optional strobe assembly
●Black “DUCT SMOKE DETECTOR” decal included for
front plate
●Blue “SMOKE”, red “FIRE” strobe lens decals included for
both horizontal and vertical mounting
Strobe Connection
The strobe assembly provides visual indication of alarm
conditions, and is connected to the indicator/control
assembly via the provided polarized connector.
To install the strobe module, simply plug the provided
connector onto the pins as indicated on the rear of the
indicator/control module. Snap the strobe lens into the cover
plate, and install cover plate following completion of remote
module wiring.
NOTE: The strobe and audible buzzer features are not ADA
compliant, and not intended for life safety notification or
evacuation purposes (public mode). These functions are for
duct smoke detector status indication only (private mode).
Duct Smoke Detector
Remote Accessories
Universal Voltage Models Compatible with
230 VAC, 115 VAC, 24 VAC or 24 VDC operation
2650-760 Ionization • 2650-761 Photoelectric
2650-660 Ionization • 2650-661 Photoelectric
2650-560 Ionization • 2650-561 Photoelectric
NEW ACCESSORIES
591S
592SC
Audible Buzzer Configuration
There are two jumpers located on the rear of the
indicator/control assembly. To enable audible buzzer
operation for Alarm or Trouble conditions, simply leave the
jumpers in place. To disable either or both functions,
remove the appropriate jumper(s).
TBL
ALM
Buzzer will
function on
both Alarm
and Trouble
Conditions
Buzzer will
function on
on Alarm
Condition
only
Buzzer will
function
on Trouble
Condition
only
Buzzer
will not
function
on Alarm
or Trouble
Conditions
TBL
ALM
TBL
ALM
TBL
ALM
591 Series Remote Accessory Controllers
591W Remote Indicator/Control Assembly w/White Single Gang Cover Plate
591R Remote Indicator/Control Assembly w/Red Single Gang Cover Plate
591S Remote Indicator/Control Assembly w/Stainless Steel Single Gang Cover Plate
592 Series Remote Accessory Controllers with Strobe
592WC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); White Double Gang Cover Plate
592WO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); White Double Gang Cover Plate
592RC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Red Double Gang Cover Plate
592RO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate
592SC Remote Indicator/Control Assembly w/Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate
592SO Remote Indicator/Control Assembly w/Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate
593 Series Remote Accessory Strobes (as an optional field upgrade kit for existing installed 591 Series Controllers)
593RC Strobe Assembly (Clear Lens); Red Double Gang Cover Plate
593RO Strobe Assembly (Opaque Lens); Red Double Gang Cover Plate
593SC Strobe Assembly (Clear Lens); Stainless Steel Double Gang Cover Plate
593SO Strobe Assembly (Opaque Lens); Stainless Steel Double Gang Cover Plate
593WC Strobe Assembly (Clear Lens); White Double Gang Cover Plate
593WO Strobe Assembly (Opaque Lens); White Double Gang Cover Plate
Products
Controls Americas
515 South Promenade Avenue
Corona California 92879-1736 USA
Cust. Svc. Telephone +1 800 951 5526
Cust. Svc. Facsimile +1 630 260 7299
[email protected]
3505 Laird Road Unit #14
Mississauga Ontario L5L 5Y7 Canada
Cust. Svc. Telephone +1 800 387 7978
Cust. Svc. Facsimile +1 905 828 1265
[email protected]
Technical Service
Telephone +1 800 445 8299
Facsimile +1 630 260 723
[email protected]
© 2006 Invensys Controls Americas 6/06 - #150-1991
Power Requirements: Standby 13mA
Alarm LED 22mA
Trouble with Buzzer 33mA
Trouble Silenced 33mA
Trouble without Buzzer 13mA
Alarm with Buzzer 37mA
Alarm Silenced with Buzzer 37mA
Alarm with Buzzer and Strobe 154mA
Alarm Silenced with Buzzer and Strobe 157mA
Lamp Test with Buzzer 62mA
Lamp Test with Buzzer Silenced 52mA
Sound Pressure: 60db @ 10 ft.
Dimensions: Single Gang Plate:
4-1/2” (114.3 mm) H x 2-3/4”
(69.85 mm) W
Double Gang Plate:
4-1/2” (114.3 mm) H x 4-1/2”
(114.33 mm) W
Wiring: 14-28 AWG. Solid or Stranded
Approvals: U.L. Listed for use with Firex duct
smoke detectors including all 2650
Series duct smoke detectors
UL URRQ, URRQ7.S7425 / CSFM / MEA
Silence and Ringback Functions
On the occasion where an audible alarm or trouble condition needs to be silenced while the detector
condition is inspected and remedied, the indicator/control module provides a silence function. The slide
switch located on the front of the module is pushed DOWN to activate the silence function.
Upon correction of the notified condition, the silenced buzzer will resume sounding. The ringback
feature serves as a reminder to reset the silence switch to the “normal”, UP position.
Note that the strobe module, when installed, will not stop operating when the silence function is engaged.
Wiring
For appropriate duct detector wiring terminals, please refer to detector and remote
accessory installation instructions.
Normal
“Standby”
Mode
Silenced
Mode
T
H
R
E
E
Y
E
A
R
W
A
R
R
A
N
T
Y
S
T
A
T
E
O
F
C
A
L
I
F
O
R
N
I
A
S
T
A
T
E
F
I
R
E
M
A
R
S
H
A
L
L
I
S
T
I
N
G
S
E
R
V
I
C
E
R
US
LISTED
268A Listed
MEA ACCEPTED

This manual suits for next models

14

Other Firex Smoke Alarm manuals

Firex FADCQ User manual

Firex

Firex FADCQ User manual

Firex ADHB User manual

Firex

Firex ADHB User manual

Firex H230 User manual

Firex

Firex H230 User manual

Firex AD User manual

Firex

Firex AD User manual

Firex AD User manual

Firex

Firex AD User manual

Firex 110-1011E User manual

Firex

Firex 110-1011E User manual

Firex TPCI User manual

Firex

Firex TPCI User manual

Firex KF30 User manual

Firex

Firex KF30 User manual

Firex I240C User manual

Firex

Firex I240C User manual

Firex 4480 User manual

Firex

Firex 4480 User manual

Firex ADH User manual

Firex

Firex ADH User manual

Firex G-6GC User manual

Firex

Firex G-6GC User manual

Firex i4618AC Series User manual

Firex

Firex i4618AC Series User manual

Firex 2650-760 User manual

Firex

Firex 2650-760 User manual

Firex 2650-560 User manual

Firex

Firex 2650-560 User manual

Firex I240C User manual

Firex

Firex I240C User manual

Firex G-6 User manual

Firex

Firex G-6 User manual

Firex AD User manual

Firex

Firex AD User manual

Firex CCPB User manual

Firex

Firex CCPB User manual

Firex A User manual

Firex

Firex A User manual

Firex FADCM User manual

Firex

Firex FADCM User manual

Firex FADC User manual

Firex

Firex FADC User manual

Firex 242 User manual

Firex

Firex 242 User manual

Firex 46184 User manual

Firex

Firex 46184 User manual

Popular Smoke Alarm manuals by other brands

Marmitek SD90 Advanced Use

Marmitek

Marmitek SD90 Advanced Use

REV 23030 user manual

REV

REV 23030 user manual

Panasonic 1740 Specifications

Panasonic

Panasonic 1740 Specifications

x-sense XP01 user manual

x-sense

x-sense XP01 user manual

Kidde 914 Start guide

Kidde

Kidde 914 Start guide

Profile 566025002 manual

Profile

Profile 566025002 manual

Kidde I5000 Specifications

Kidde

Kidde I5000 Specifications

olympia electronics BSR-6155 quick start guide

olympia electronics

olympia electronics BSR-6155 quick start guide

LEGRAND tynetec ZXT810 quick start guide

LEGRAND

LEGRAND tynetec ZXT810 quick start guide

bolid S2000-IPDL installation manual

bolid

bolid S2000-IPDL installation manual

Ei Electronics Ei161RC Ionisation product manual

Ei Electronics

Ei Electronics Ei161RC Ionisation product manual

Elkron FO31WL quick start guide

Elkron

Elkron FO31WL quick start guide

Ei Electronics Ei 100R Ionisation Technical specifications

Ei Electronics

Ei Electronics Ei 100R Ionisation Technical specifications

x-sense XS01 user manual

x-sense

x-sense XS01 user manual

FCI 301PL Series quick start guide

FCI

FCI 301PL Series quick start guide

First Alert SA300 user manual

First Alert

First Alert SA300 user manual

Abus RM40Li user manual

Abus

Abus RM40Li user manual

Linear DXS-73 installation instructions

Linear

Linear DXS-73 installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.