ELECTROCHEMICAL
CO SENSOR
Most accurate technology available for
detecting carbon monoxide as compared to
other sensing technologies.
OPTIPATH 360
TECHNOLOGY
TM
Provides 360 degrees of direct access
to the smoke sensing chamber.
SWEEPING
HORN TONE
Varying horn tone makes it easier for elderly
with normal age related hearing loss to hear
the alarm.
TWO LOCKING
FEATURES
Pins are provided to lock battery drawer
and/or alarm to base. Perfect for
apartment, dormitory or hotel
applications.
CAT. SCO5B Series Two AA Battery Powered
First Alert Model SCO5 is a battery operated single station photoelectric smoke
and carbon monoxide combination alarm specifically designed for residential and
institutional applications including sleeping rooms of hospitals, hotels, motels,
dormitories, and other multifamily dwellings as defined in standard NFPA 101.
Model SCO5 has been fully tested and complies with, UL217, UL2034, CSFM,
NFPA 72, and NFPA 101 and other agencies that model their codes after the
above agencies. It meets building codes where battery operated photoelectric
smoke and carbon monoxide combination alarms are required and with model
building codes published by the ICC.
First Alert Model SCO5 is a state of the art smoke and CO combination alarm
designed to provide early warning of a fire or carbon monoxide danger. It
features a photoelectric smoke sensing chamber and an electrochemical CO
sensor. It features a Sweeping Horn Tone that has a lower and varying frequency
that makes it easier for the elderly with normal age related hearing loss to hear
the horn. Two AA alkaline batteries power supply and a single button test/silence.
This alarm has two silence features. Low Battery Silence: Temporarily silence the
low battery chirp for up to eight hours. Alarm Silence: Silence alarm for several
minutes. Optipath 360 technologyTM provides 360 degrees of direct access to the
smoke sensing chamber. It also features tamper resistant locking pins that lock
the alarm to the mounting bracket and/or the battery drawer to prevent removal
of battery. Battery installation and removal can occur while the unit is mounted
to the ceiling or wall via the slide out battery drawer. Designed for wall or ceiling
mounting. Includes mounting anchors
and screws.
PHOTOELECTRIC
SMOKE & CO
COMBO
ALARM
brkelectronics.com
ARCHITECTURAL AND ENGINEERING SPEC
INSTALLATION OF ALARM
The smoke/CO combination alarm shall be a First Alert Model SCO5 and shall provide
at a minimum the following features and functions:
1. A Photoelectric smoke sensing chamber and an electrochemical CO sensor.
2. The unit shall have a lower and varying horn frequency to to make it easier for
the elderly with normal age related hearing loss to better hear the horn
3. Fully screened smoke sensing chamber to resist entry of small insects thereby
reducing the probability of unwanted alarms and be capable of self restoring.
4. Powered by supervised 2 AA alkaline batteries and a solid state piezo horn rated at
85dB at 10 ft.
5. A visual green LED power-on indicator to confirm unit is receiving power. A visual
red indicator to show unit is alarm.
6. A full function test button should check all alarm functions by simulating a smoke
and CO condition, causing the unit to alarm.
7. Two Silence features - Low Battery Silence: Silence low battery chirp for up to 8
hours. Alarm Silence: Temporarily silence unwanted nuisance alarms.
8. Optipath 360 TechnologyTM - provides 360 degrees of direct access to the
smoke sensing chambers.
9. Two Locking features - tamper resistant locking pins that lock battery drawer
and/or alarm to mounting bracket.
10. The unit shall be capable of operating between 40°F (4°C) and
100°F (38°C) and relative humidity between 10% and 95%.
11. The unit shall contain mounting hardware and shall be listed for wall
or ceiling mounting.
12. The unit shall at a minimum meet the requirements of UL217, UL2034, CSFM,
NFPA 72, NFPA 720, NFPA 101, ICC
Installation of this alarm must conform to NFPA 72 and NFPA 720. Always check your local
building codes. Follow all instructions for placement as outlined in the user’s manual.
SHIPPING SPECS:
TECHNICAL SPECS
Individual Carton Dimensions 5.13 ”L x 2.380”W x 5.13”H
Weight 0.66lbs.
Cube 0.036 ft3
UPC 0 29054 00347 8
Master Carton Dimensions 10.750”L x 7.880”W x 11.06”H
Master Pack 12
Weight 8.4lbs.
Cube 0.542 ft3
I2 of 5 700 29054 00347 7
Pallet Information
Cases per Layer 22
Number of Layers 4
Cases per Pallet 88
Units per Pallet 1,056
Cube 53.9 ft3
Weight 804 lbs.
©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)
3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved
First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM2954
CAT. SCO5B Series
THE PARTS OF THIS SMOKE/CO ALARM
BOTTOM OF ALARM
1. Mounting bracket
2. Mounting Slots
3. Battery Drawer - Install
2 AA batteries here
4. Turn this way to
remove from bracket
5. Turn this way to
attach to bracket
TOP OF ALARM
1. Test/Silence button &
remote control sensor
2. Slide-open
battery drawer
3. Power/smoke alarm light
4. CO alarm light
BATTERY DRAWER LOCK
Remove Pin from
Mounting Bracket
Close Door. Insert Pin in Holes
through alarm and Battery Drawer
5.0"
TOP VIEW SIDE VIEW
MOUNTING
BRACKET
2.0"
Alarm Dimensions: 5.0” dia x 2.0”H
Weight: 8.4 oz.
Operating Voltage: 2AA Alkaline Battery Powered
Temperature Range: 40°F (4°C) to 100°F (38°C)
Humidity Range: 10% to 95% relative humidity (RH)
Audio Alarm: 85dB at 10 feet
Test/Silence: Electronically simulates smoke and CO conditions,
causing the unit to alarm and temporarily silence the alarm
Press and hold test/silence button
Alarm Reset: Automatic when smoke and/or CO clears
Smoke Sensor: Photoelectric
CO Sensor: Electrochemical
Indicator Lights/Sounds:
DC Power: Intermittent Red Light
Alarm: Audio Alarm, rapidly flashing red light by corresponding
smoke or CO indicator light
Listing: Listed to UL217 and 2034 Standards

This manual suits for next models

1

Other First Alert Smoke Alarm manuals

First Alert SA340B User manual

First Alert

First Alert SA340B User manual

First Alert SA304 User manual

First Alert

First Alert SA304 User manual

First Alert SA340 User manual

First Alert

First Alert SA340 User manual

First Alert SA10YRUKN User manual

First Alert

First Alert SA10YRUKN User manual

First Alert 7010B User manual

First Alert

First Alert 7010B User manual

First Alert SA320CN-2 User manual

First Alert

First Alert SA320CN-2 User manual

First Alert AC10-500 User manual

First Alert

First Alert AC10-500 User manual

First Alert SCO500NVA User manual

First Alert

First Alert SCO500NVA User manual

First Alert SM210 User manual

First Alert

First Alert SM210 User manual

First Alert SA302 User manual

First Alert

First Alert SA302 User manual

First Alert FG250A User manual

First Alert

First Alert FG250A User manual

First Alert SA4121C User manual

First Alert

First Alert SA4121C User manual

First Alert SA720 User manual

First Alert

First Alert SA720 User manual

First Alert SCO500A User manual

First Alert

First Alert SCO500A User manual

First Alert SLED177 User manual

First Alert

First Alert SLED177 User manual

First Alert Smoke and Carbon Monoxide Alarm SC01N User manual

First Alert

First Alert Smoke and Carbon Monoxide Alarm SC01N User manual

First Alert SA320 User manual

First Alert

First Alert SA320 User manual

First Alert P1000 User manual

First Alert

First Alert P1000 User manual

First Alert SC9120B User manual

First Alert

First Alert SC9120B User manual

First Alert SA302B User manual

First Alert

First Alert SA302B User manual

First Alert ONELINK User manual

First Alert

First Alert ONELINK User manual

First Alert ZCOMBO-G User manual

First Alert

First Alert ZCOMBO-G User manual

First Alert ZCOMBO User manual

First Alert

First Alert ZCOMBO User manual

First Alert 9120 Series User manual

First Alert

First Alert 9120 Series User manual

Popular Smoke Alarm manuals by other brands

FCI ADP-R Installation and maintenance instructions

FCI

FCI ADP-R Installation and maintenance instructions

Kidde Smoke Alarm user manual

Kidde

Kidde Smoke Alarm user manual

Kidde PI9000 user guide

Kidde

Kidde PI9000 user guide

Pirexx PX-1 Operating, installation and maintenance manual

Pirexx

Pirexx PX-1 Operating, installation and maintenance manual

brennenstuhl Brematic Pro Instructions for use

brennenstuhl

brennenstuhl Brematic Pro Instructions for use

Regin SDD-S65-RACM Instruction

Regin

Regin SDD-S65-RACM Instruction

Fire-Lite Alarms BG-12 manual

Fire-Lite Alarms

Fire-Lite Alarms BG-12 manual

FIBARO FIBEFGSD-002 quick start guide

FIBARO

FIBARO FIBEFGSD-002 quick start guide

Smartwares ELRO RM142F quick start guide

Smartwares

Smartwares ELRO RM142F quick start guide

Kidde 900-CUAR user guide

Kidde

Kidde 900-CUAR user guide

The Initiator and Company Chick-a-Dee user guide

The Initiator and Company

The Initiator and Company Chick-a-Dee user guide

ESMI EB6500A Installation and maintenance instructions

ESMI

ESMI EB6500A Installation and maintenance instructions

Perenio PECSS01 quick start guide

Perenio

Perenio PECSS01 quick start guide

System Sensor Innovair flex D4120A Installation and maintenance instructions

System Sensor

System Sensor Innovair flex D4120A Installation and maintenance instructions

Argus S1000 manual

Argus

Argus S1000 manual

CPVan CPSM03 user manual

CPVan

CPVan CPSM03 user manual

techem smoke detector 2 operating instructions

techem

techem smoke detector 2 operating instructions

Firex FADC manual

Firex

Firex FADC manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.