fisair CCE2.0 User manual

FISAIR, S.L.U. C/Uranio, 20; PoI. Ind. Aimayr, 28330 San Martín de la Vega (Madrid) Spain.
Tel: (+34) 91 692 15 14 Fax: (+34) 91 691 64 56 | info@fisair.com| fisair.com
INSTALLATION AND OPERATION MANUAL
FOR THE STAGES CONTROL PANEL (CCE2.0) FOR
FISAIR EVAPORATIVE HUMIDIFIERS
Software version 2.1 | MCCE2.0-EN-21-1
In compliance with the Rules and Standards of the European Union on Machine Safety, it is essential to read this protocol
carefully before installing any equipment.

MANUAL for the Stages Control Panel | CCE2.0
2

MANUAL for the Stages Control Panel | CCE2.0
3
Contents
1. Safety instructions................................................................................................................... 5
2. General description................................................................................................................. 6
3. Operating environment............................................................................................................ 7
4. Rating plate and machine classification:.................................................................................. 9
5. Hardware description .............................................................................................................11
6. Connections...........................................................................................................................22
7. Supervision ............................................................................................................................28
8. Configuration..........................................................................................................................30
8.1. Emptying.............................................................................................................................30
8.1.1. Emptying by conductivity control: ....................................................................................30
8.1.2. Standard emptying:.........................................................................................................31
8.1.3. No emptying (never):.......................................................................................................31
8.2. Configuration Prior to Start-Up (Pre-Start-up).....................................................................32
8.3. Stages configuration:..........................................................................................................33
8.4. Conf. 0...10V or 4...20 mA: .................................................................................................34
8.5. UV lamp configuration.........................................................................................................34
8.6. Bus configuration................................................................................................................35
8.6.1. MODBUS: TCP/IP y RTU................................................................................................35
8.6.2. BACnet/IP:......................................................................................................................39
8.7. Language............................................................................................................................43
8.8. Date....................................................................................................................................43
9. Settings..................................................................................................................................44
9.1. SET-POINT µS/cm (if applicable) .......................................................................................44
9.2. TIMER T01 (ex SW1 AB)....................................................................................................44
9.3. TIMER T02 (ex SW1 CD) ...................................................................................................45
9.4. TIMER T03 (ex SW2 AB)....................................................................................................45
9.5. TIMER T04 (ex SW2 CD) ...................................................................................................45
9.6. TIMER T05 (ex SW3 AB)....................................................................................................45
9.7. TIMER T06 (ex SW3 CD) ...................................................................................................46
9.8. TIMER T07 (ex SW4 CD) ...................................................................................................46
9.9. TIMER T08.........................................................................................................................46
10. Calibration ..........................................................................................................................47
11. Launching...........................................................................................................................48
12. Alarms................................................................................................................................52

MANUAL for the Stages Control Panel | CCE2.0
4
13. Declaration of conformity....................................................................................................53
13.1. D.C. Machine...............................................................................................................53
13.2. D.C. Partly completed machinery.................................................................................54
14. Warranty.............................................................................................................................55
ANEX:
E09489-C WIRING DIAGRAM (230VAC)
E09490-C WIRING DIAGRAM (400VAC)

MANUAL for the Stages Control Panel | CCE2.0
5
1. Safety instructions
Need to consign the control panel for maintenance and revision
The machine controlled by CCE2.0 panel must not be manipulated when it is in operation.
Facing any problem that is detected in the machine during its operation, disconnect it
and set the main switch of the CCE2.0 panel using a padlock.
Installation of a residual current device in the power supply line.
The installer has to install a specific residual current device in the machine's electrical
power circuit.
FISAIR disclaims any liability if not all the installation and operating instructions it has
provided are complied with; if the products have been modified or altered without the written
consent of FISAIR; or if the products have been subjected to improper use, mishandling,
alteration, improper maintenance or show signs of negligent use or being involved in an
accident. These situations could include an incorrect power connection, impacts with other
objects, removal or disarming of security fittings/measures, etc.

MANUAL for the Stages Control Panel | CCE2.0
6
Max.25m
2. General description
The stages control panel has been specifically designed for the interconnection and supervision of
the accessories supplied with the FISAIR Evaporative Humidifiers. The incorporation of the CCE2.0
provides a more accurate, simple and reliable integration for this in air handling units.
The control panel manages all the field components of FISAIR Evaporative Humidifiers:
•Water recirculation pump
•Detector of the minimum and maximum basin water level
•Basin water supply solenoid valve
•Emptying/draining motor-valve in the basin
•Solenoid valves for different Stages
•UV lamp water treatment system (optional)
•Water conductivity control (optional)
•Modbus TCP/IP (optional)
•Modbus RTU (optional)
•BACnet/IP (optional)
* For the MAXIMUM distance of the conductivity probe, ask FISAIR when
CCE2.0 + Conductivity Control
Figure 1: Examples of installation of CCE2.0 on vertical wall and CCE2.0 integrated in the AHU
*

MANUAL for the Stages Control Panel | CCE2.0
7
3. Operating environment
The Stages Control panel is supplied in an insulating box composed of a bottom and a hinged lid
made of steel with a surface finish of RAL7035 grey weather-resistant epoxy-polyester powder with
IP54 degree of protection according to IEC-60529 and IK10 impact protection according to
IEC62262.
Operating environment temperature and humidity conditions:
•Relative humidity [5%... 95% HR], no condensation.
•Temperature [-10 °C ... +40°C]
The recommended gaps for connection, inspection and maintenance must be observed during
installation. If the box is drilled in the locations indicated for mounting, it must be ensured that a
degree of protection ≥ IP54 is maintained.
The basic control panel weighs 7,2 kg and must be installed vertically on the wall (see Figure 1) to
maintain the degree of protection IP54. Figures 2.1 and 2.2 show the minimum service spaces to be
observed and the drill hole measurements for mounting.
Figure 2.1: Vertical section: front, open door. Figure 2.2: Cross section: door closed/open
(Interior)

MANUAL for the Stages Control Panel | CCE2.0
8
INSTALLATION OF THE CONTROL PANEL OUTSIDE:
Whenever the control panel is installed outdoors, it
must be placed under an appropriate cover to protect
it from the direct incidence of rain and sun (considering
that 40ºC cannot be exceeded in the installation area):

MANUAL for the Stages Control Panel | CCE2.0
9
4. Rating plate and machine classification:
The rating plate provides essential information about the technical features of the machine.
The EC MachinerySafety Regulation requires allmachinery operated within the European Economic
Community to have a rating plate indicating its main features, the machine serial number and the
manufacturer's name inscribed in a durable manner.
According to article 2, section g of the Machinery Directive 2006/42/CE - RD 1644/2008, ‘partly
completed machinery’ means
“an assembly which is almost machinery, but which cannot in itself perform a specific application.
A drive system is partly completed machinery. Partly completed machinery is intended only to be
incorporated into or assembled with other machinery or other partly completed machinery or
equipment, thereby forming machinery to which this Directive applies”
Therefore, the CCE2.0 stages control panel is classified as a “partly completed machinery”
Nota: If the CCE2.0 stages control panel is supplied together with a device from the HEF
range, the set is classified as "machine"
Location of the rating plate:

MANUAL for the Stages Control Panel | CCE2.0
10
The rating plate shows the following information for the particular CCE2.0 stages control panel:
•Model
• Serial No.: equipment serial number
• Power supply
• Maximum power
• Rated current
• Wiring diagram
• Configuration program
• Machine type
• Designed according to the directive:
• FISAIR equipment you can join
• Year and place of manufacture.
•Service QR code and Warranty activation

MANUAL for the Stages Control Panel | CCE2.0
11
5. Hardware description
Figure 3.1: CCE2.0 front cover

MANUAL for the Stages Control Panel | CCE2.0
12
Figure 3.1: CCE2.0 front cover
Figure 3.2: SEF-028.1 and SEF-032.1 v2 Power cards

MANUAL for the Stages Control Panel | CCE2.0
13
Figure 3.3: CCE2.0 Open (location SEF-028.1 and SEF-032.1 v2 cards)

MANUAL for the Stages Control Panel | CCE2.0
14
Figure 3.4: Inside cover CCE2.0 (standard)

MANUAL for the Stages Control Panel | CCE2.0
15
Figure 3.5: Inside cover CCE2.0 (optional data bus and conductivity cards. IP
Connection)

MANUAL for the Stages Control Panel | CCE2.0
16
Figure 3.6: Inside cover CCE2.0 (optional data bus and conductivity cards. RTU
Connection)

MANUAL for the Stages Control Panel | CCE2.0
17
LED / Key
No.
Description, Function and Article Code
1
Disconnector switch (I1) for cutting and isolating the supply
voltage; possibility of locking by padlock (not supplied)
Art. Cod.: 64300129
2
HMI. Command and display interface SEF-027.1
Art. Cod.: 52300012
3
LED. Yellow. Live equipment
4
LED. Red. General fault
5
Operating key in Manual mode
6
Start/stop status change button
7
Operating key in Automatic mode.
8
OK button (ENTER)
9
Back button (ESC)
10
Navigation keys
11
LED. Blue. UV Lamp is operating
12
LED. Yellow. Indicates the water supply solenoid valve is
powered
13
LED. Green. Indicates the drain valve motor is powered
14
LED. Green. Indicates the drain motor valve is open (requires
feedback connection)

MANUAL for the Stages Control Panel | CCE2.0
18
LED / Key/Component
Ref.
Description, Function and Article Code
15
Float switch status LED:
Yellow. Indicates level below minimum
Green. Indicates operating level
Red. Indicates maximum water level
Flashing red: Indicates fault
16
Water pump status LED:
Green. Water pump running
Red. Malfunction
17
Display screen
18
Power terminals (X1)
19
Magneto-thermal circuit breaker (U1 in electrical diagram) to
protect water pump
Art. Cod.: 64350010 (55 W single-phase pump)
Art. Cod.: 64350010 (60 W 3-phase pump)
Art. Cod.: 64350005 (90 W single-phase pump)
Art. Cod.: 64350004 (125 W 3-phase pump)
Art. Cod.: 64350005 (240W 3-phase pump)
Art. Cod.: 64350020 (370W single-phase pump)
20
Electronic power card SEF-028.1
Art. Cod.: 523000013
22
Electronic power card SEF-032.1 v2 for steps control.
Art Cod.: 523000017

MANUAL for the Stages Control Panel | CCE2.0
19
LED / Key/ Component
Ref.
Description, Function and Article Code
29
RL8 relay for motor-valve drain/emptying
Art. Cod 64130018
23
Fuse F2 for auxiliary power protection
Art. Cod: 64600012
24
Fuse F3 to protect the water supply solenoid valve
Art. Cod.: 64600012
25
Fuse F4 for drain/emptying motor valve protection
Art. Cod.: 64600012
26
Fuse F5 for UV lamp protection
Art. Cod.: 64600013
27
Relay RL1 for water recirculation pump
Art. Cod.: 64130019
28
Relay RL2 for UV lamp
Art. Cod.: 64130018
21
Relay RL3 for water supply solenoid valve
Art. Cod.: 64130018
30
Central processing card SEF-025.1
Art. Cod.: 52300010

MANUAL for the Stages Control Panel | CCE2.0
20
LED / Key/ Component
Ref.
Description, Function and Article Code
31
Battery 3V CR2032
Art. Cod.: 69101000
32
40 pins Flat cable connector. Between SEF-28.1 and SEF-
025.1
-
CCE2.0 rating plate. See location in chapter 4.
34
Conductivity probe with 2 m cable for CCE2.0+C (optional)
Art. Cod.: 64220250
35
Conductivity sensor card SEF-026 for CCE2.0 +C (optional)
Art. Cod.: 52300011
36.1
Communication card via data bus: Modbus TCP/IP 2.0
(optional) SEF-029
Art. Cod.: 52300014
Communication card SEF-031 via data bus: BACnet / IP
2.0(optional)
Art. Cod.: 52300014
36.2
Communication card SEF-030 via data bus: Modbus RTU 2.0
(optional)
Art. Cod.: 52300015
Table of contents
Other fisair Control Panel manuals
Popular Control Panel manuals by other brands

Jet
Jet 197 Installation and user manual

Bosch
Bosch Rexroth IndraControl VDP 92.3 Project planning manual

Steamist
Steamist TSC-250 Installation and operating instructions

Gilson
Gilson HM-630 operating manual

Siemens
Siemens SIMATIC HMI 177 operating instructions

Flybox
Flybox Vigilus Series installation manual

Permalert
Permalert PAL-AT AT30C installation manual

Mircom
Mircom FA-300 Series Installation and operation manual

Fourgroup
Fourgroup DUPLEX-UP Use and installation guide

Intellitouch
Intellitouch Pool and Spa Control System installation guide

Summit Systems
Summit Systems SFC-500 SERIES installation instructions

Elvox
Elvox SL24.W Installer manual