Thank you for purchasing a top quality, factory tested pump.
Page
General Safety .....................................................................................................2
Installation.......................................................................................................4, 5
Electrical..........................................................................................................6, 7
Operation ............................................................................................................8
Troubleshooting...................................................................................................9
Repair Parts ......................................................................................................10
Warranty............................................................................................................11
For parts or assistance, call Flotec Customer Service at 800-365-6832
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
Electrical 7
Wiring
Risk of electric shock. Can shock, burn or kill.
• Ground motor before connecting to electrical power
supply. Failure to ground motor can cause severe or
fatal electrical shock hazard.
• Do not ground to a gas supply line.
• To avoid dangerous or fatal electrical shock, turn
OFF power to motor before working on electrical
connections.
• Supply voltage must be within ±10% of nameplate
voltage. Incorrect voltage can cause fire or damage
motor and voids warranty. If in doubt consult a
licensed electrician.
• Use wire size specified in Wiring Chart (below). If
possible, connect pump to a separate branch circuit
with no other appliances on it.
• Wire motor according to diagram on motor
nameplate. If nameplate diagram differs from
diagrams above, follow nameplate diagram.
Step 1. Install, ground, wire and maintain this pump in
accordance with electrical code requirements.
Consult your local building inspector for
information about codes.
Step 2. Provide a correctly fused disconnect switch for
protection while working on motor. Consult
local or national electrical codes for switch
requirements.
Step 3. Disconnect power before servicing motor or
pump. If the disconnect switch is out of sight
of pump, lock it open and tag it to prevent
unexpected power application.
Step 4. Ground the pump permanently using a wire of
the same size as that specified in wiring chart,
below. Make ground connection to green
grounding terminal under motor canopy marked
GRD. or .
Step 5. Connect ground wire to a grounded lead in the
service panel or to a metal underground water
pipe or well casing at least 10 feet long. Do not
connect to plastic pipe or insulated fittings.
Step 6. Protect current carrying and grounding
conductors from cuts, grease, heat, oil, and
chemicals.
Step 7. Connect current carrying conductors to
terminals L1 and L2 under motor canopy. When
replacing motor, check wiring diagram on motor
nameplate against Figure 4. If the motor wiring
diagram does not match Figure 4, follow the
diagram on the motor.
NOTICE 115/230 Volt single phase models are shipped
from factory with motor wired for 230 volts. If power
supply is 115 volts, remove motor canopy and change
switch dial on motor as shown in Figure 4. Do not try to
run motor as received on 115 volt current.
Step 8. Motor has automatic internal thermal overload
protection. If motor has stopped for unknown
reasons, thermal overload may restart it
unexpectedly, which could cause injury or
property damage. Disconnect power before
servicing motor.
Step 9. If this procedure or the wiring diagrams are
confusing, consult a licensed electrician.
For parts or assistance, call Flotec Customer Service at 800-365-6832
Wiring Chart – Recommended Wire and Fuse Sizes for 115 and 230 volts
* Duel element or Fusetron time delay fuses recommended for all motor circuits.
Pump
Model HP Volts
Max
Load
Amp
Branch
Fuse
Rating*
Amp
AWG Min. Wire
Size (mm2)
Distance in Feet (Meters) From Motor to Supply
0 - 100
(0 - 30)
101 - 200
(31 - 61)
201 - 300
(62 - 91)
301 - 400
(91 - 122)
401 - 500
(123 - 152)
AWG Wire Size (mm2)
FP5162 1 115/230 14.8/7.4 20/15 12/14 (3/2) 12/14 (3/2) 8/14 (8.4/2) 6/14 (14/2) 6/12 (14/3) 4/10 (21/5.5)
FP5172 1 - 1/2 115/230 19.9/9.9 20/15 10/14 (5.5/2) 10/14 (5.5/2) 8/14 (8.4/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
FP5182 2 115/230 24/12 20/15 10/14 (5.5/2) 10/14 (5.5/2) 6/14 (14/2) 6/12 (14/3) 4/10 (21/5.5) 4/10 (21/5.5)
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
Troubleshooting 9
For parts or assistance, call Flotec Customer Service at 800-365-6832
Performance Chart in GPM(LPM)
All models except FP5182 and FP5182C have discharge and suction size of 1-1/2
”
NPT. FP5182 and FP5182C have 2
”
NPT suction and discharge.
Risk of electric shock. Can shock, burn or kill.
To discharge capacitor, hold insulated handle screwdriver BY THE HANDLE and short
capacitor terminals together. Do not touch metal screwdriver blade or capacitor terminals. If in doubt, consult a qualified electrician.
Discharge
Pressure
PSI (kPa)
FP5162 - 1HP FP5172 - 1 - 1/2 HP FP5182, FP5182C - 2HP
Height of Pump Above Water in Feet (Meter)
5’ (1.5) 10’ (3) 15’ (4.6) 20’ (6.1) 5’ (1.5) 10’ (3) 15’ (4.6) 20’ (6.1) 5’ (1.5) 10’ (3) 15’ (4.6) 20’ (6.1)
10 (69) 55 (208) 49 (185) 48 (181) 45 (170) 67 (254) 61 (231) 56 (212) 46 (174) 69 (261) 64 (242) 65 (246) 62 (235)
15 (103) 51 (193) 46 (174) 45 (170) 44 (166) 66 (250) 58 (220) 55 (208) 45 (170) 65 (246) 62 (235) 60 (227) 57 (215)
20 (138) 45 (170) 42 (159) 39 (148) 37 (140) 61 (231) 56 (212) 54 (204) 44 (166) 59 (223) 56 (212) 54 (204) 52 (197)
25 (172) 38 (144) 35 (132) 32 (121) 29 (110) 55 (208) 52 (197) 51 (193) 43 (163) 52 (197) 50 (189) 48 (181) 46 (174)
30 (207) 31 (117) 28 (106) 24 (90) 20 (76) 48 (181) 45 (170) 44 (166) 37 (14) 47 (178) 45 (170) 42 (159) 40 (151)
35 (241) 23 (87) 19 (72) 16 (60) 11 (42) 39 (147) 37 (140) 34 (129) 28 (106) 42 (159) 38 (144) 35 (132) 32 (121)
40 (276) 17 (64) 13 (49) 8 (30) 33 (125) 27 (102) 20 (76) 11 (42) 34 (129) 30 (113) 27 (102) 23 (87)
45 (310) 18 (68) 14 (53) 8 (30) 25 (95) 18 (68) 13 (49) 10 (38)
50 (345) 14 (53) 7 (26)
Symptom Possible Cause(s) Corrective Action
Motor will not run Disconnect switch is off. Be sure switch is on.
Fuse is blown or circuit breaker tripped Replace fuse or reset breaker.
Starting switch is defective. DISCONNECT POWER; Replace starting switch.
Wire ast motor are loose, disconnected, or wired
incorrectly.
Refer to instructions on wiring. DISCONNECT POWER; check and tighten
all wiring.
Motor runs hot and
overload kicks off or
motor does not run and
only hums.
Motor is wired incorrectly Refer to instructions on wiring.
Voltage is too low. Check voltage being supplied to motor. Install heavier wiring if wire size is
too small (See Electrical / Wiring Chart)
Motor Runs but no water
is delivered*
*(Note: Stop pump;
then check prime before
looking for other causes.
Unscrew priming plug
and see if water is in
priming hole).
Pump in new installation did not pick up prime
through:
In new installation:
1. Improper priming 1. Re-prime according to instructions.
2. Air leaks. 2. Check all connections on suction line, with soapy water or shaving
cream
3. Leaking foot valve or check valve 3. Replace foot valve or check valve.
4. Pipe size too small 4. Re-pipe using size of suction and discharge ports on pump.
Pump has lost prime through: In installation already in use:
1. Air leaks 1. Check all connections on suction line and shaft seal with soapywater.
2. Water level bellow suction pipe inlet. 2. Lower suction line into water and re-prime. If receding water level in
well exceeds 25’ (7.6M), a deep well pump is needed.
Impeller is plugged Clean impeller
Check valve or foot valve is stuck shut Replace check valve or foot valve
Pipes are frozen Thaw pipes. Bury pipes below frost line. Heat pit or pump house.
Foot valve and/or strainer are buried in sand or mud Raise foot valve and/or strainer above bottom of water source.
*Pump does not deliver
water to full capacity.
Water level in well is lower than estimated A deep well jet will be needed if your well is more than 25’ (7.6M) dept to
water.
Steel piping (if used) is corroded or limed, causing
excess friction
Replace with plastic pipe where possible, otherwise with new steel pipe.
Piping is too small in size Re-pipe using size of suction and discharge ports on pump
Pump not being supplied with enough water Add additional well points.
Pump leaks around
clamp
Clamp loose STOP PUMP, tighten clamp nut 1 - 2 turns. Alternately tighten and tap on
clamp with mallet to seat O-Ring. Do not overtighten.
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162
Warranty 11
Retain Original Receipt for Warranty Eligibility
Limited Warranty
This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
FLOTEC warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and
workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months
from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at FLOTEC’s
option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only
and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty
does not cover repair when normal use has exhausted the life of a part or the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility
is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or
replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase).
Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store - contact FLOTEC Customer Service at
800-365-6832.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet
where it was purchased or to the factory immediately after the discovery of any alleged defect. FLOTEC will subsequently take
corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after
the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rentalapplications.
Sewage Pumps
DO NOT return a sewage pump (that has been installed) to your retail store. Contact FLOTEC Customer Service. Sewage pumps
that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
• Wearrubbergloveswhenhandlingthepump;
• Forwarrantypurposes,returnthepump’scordtagandoriginalreceiptofpurchasetotheretailstore;
• Disposeofthepumpaccordingtolocaldisposalordinances.
Exceptions to the Twelve (12) Month Limited Warranty
Product Warranty Period
FP0F360AC, FP0FDC 90 days
FP0S1775A, FP0S1790PCA, FP0S2400A, FP0S2450A, FP0S4100X, FP2800DCC, FPCP-20ULST, FPPSS3000, FPSC2150A,
FPSC3150A, FPSC3350A 2 Years
4” Submersible Well Pumps, FP0S3200A, FP0S3250A, FP0S6000A, FPSC1725X, FPSC2200A, FPSC2250A, FPSE3601A,
FPPSS5000 3 Years
FP7100 Series Pressure Tanks, E100ELT, E3305TLT, E3375TLT, E5005TLTT, E50TLT, E50VLT, E75STVT, E75VLT, FPSC3200A,
FPSC3250A, FPSC4550A 5 Years
General Terms and Conditions; Limitation of Remedies
You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not
apply to the following: (1) acts of God; (2) products which, in FLOTEC’s sole judgment, have been subject to negligence, abuse,
accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4)
atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system,
or operation at pressures in excess of recommended maximums.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING LIMITED WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED
WARRANTIES, INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE. THE FOREGOING LIMITED WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION
PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an
implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights
and You may also have other rights which vary from state to state.
FLOTEC • 293 Wright Street • Delavan, WI USA 53115
Phone: 800-365-6832 • Fax: 800-526-3757 • www.flotecwater.com
www.PumpAgents.com - Click here for Pricing/Ordering for Pumps and Parts
Flotec Pumps FP5162

This manual suits for next models

3

Other Flotec Water Pump manuals

Flotec FP4155 User manual

Flotec

Flotec FP4155 User manual

Flotec OMNIA 80/5 User manual

Flotec

Flotec OMNIA 80/5 User manual

Flotec FPXS2400A Series User manual

Flotec

Flotec FPXS2400A Series User manual

Flotec FP855 User manual

Flotec

Flotec FP855 User manual

Flotec FP6022 Series User manual

Flotec

Flotec FP6022 Series User manual

Flotec AutoJet 1000 User manual

Flotec

Flotec AutoJet 1000 User manual

Flotec 4202A Series User manual

Flotec

Flotec 4202A Series User manual

Flotec FP4200 Series User manual

Flotec

Flotec FP4200 Series User manual

Flotec FPSE3500A User manual

Flotec

Flotec FPSE3500A User manual

Flotec FPSC2200A-10 User manual

Flotec

Flotec FPSC2200A-10 User manual

Flotec FPCP Series User manual

Flotec

Flotec FPCP Series User manual

Flotec E50TLT User manual

Flotec

Flotec E50TLT User manual

Flotec FP0FDC User manual

Flotec

Flotec FP0FDC User manual

Flotec EVO-MULTIPRESS 340 SX LOGIC SAFE User manual

Flotec

Flotec EVO-MULTIPRESS 340 SX LOGIC SAFE User manual

Flotec FP5712 User manual

Flotec

Flotec FP5712 User manual

Flotec AutoJet 1000 User manual

Flotec

Flotec AutoJet 1000 User manual

Flotec N4151080 User manual

Flotec

Flotec N4151080 User manual

Flotec WATERPRESS 1000 User manual

Flotec

Flotec WATERPRESS 1000 User manual

Flotec FPI800DCC User manual

Flotec

Flotec FPI800DCC User manual

Flotec Easy Sump FPRP3250C User manual

Flotec

Flotec Easy Sump FPRP3250C User manual

Flotec FP7100 User manual

Flotec

Flotec FP7100 User manual

Flotec FP7 KV User manual

Flotec

Flotec FP7 KV User manual

Flotec FPSC5000A User manual

Flotec

Flotec FPSC5000A User manual

Flotec SCM 4 PLUS Series User manual

Flotec

Flotec SCM 4 PLUS Series User manual

Popular Water Pump manuals by other brands

Shibaura FT450-A owner's manual

Shibaura

Shibaura FT450-A owner's manual

Beckett CB15 quick guide

Beckett

Beckett CB15 quick guide

Westinghouse WH50BBU owner's manual

Westinghouse

Westinghouse WH50BBU owner's manual

Graco Mongoose Series Instructions - parts

Graco

Graco Mongoose Series Instructions - parts

Go EBSRAY V Series Installation, operation and maintenance instructions

Go

Go EBSRAY V Series Installation, operation and maintenance instructions

Baker Hughes Druck PV 62X instruction manual

Baker Hughes

Baker Hughes Druck PV 62X instruction manual

Atlas Copco LRP 700 VSD+ Instruction book

Atlas Copco

Atlas Copco LRP 700 VSD+ Instruction book

Oase NEPTUN 600 operating instructions

Oase

Oase NEPTUN 600 operating instructions

Graco G3 Pro instructions

Graco

Graco G3 Pro instructions

Central Machinery CENTRAL MACHINERY 92274 Assembly and operating instructions

Central Machinery

Central Machinery CENTRAL MACHINERY 92274 Assembly and operating instructions

Xylem Lowara LS Series Installation,operation and maintenance instruction

Xylem

Xylem Lowara LS Series Installation,operation and maintenance instruction

IWAKI APN-S041-D3 instruction manual

IWAKI

IWAKI APN-S041-D3 instruction manual

BUSCH R 5 RA 0160 D instruction manual

BUSCH

BUSCH R 5 RA 0160 D instruction manual

Lowara BG Series Installation and operating instructions

Lowara

Lowara BG Series Installation and operating instructions

Ribimex PRPVF500AUTO User and maintenance manual

Ribimex

Ribimex PRPVF500AUTO User and maintenance manual

Hyundai power products HY50-A-1 Original instructions

Hyundai power products

Hyundai power products HY50-A-1 Original instructions

DÖRR EcoPump VP Operation manual

DÖRR

DÖRR EcoPump VP Operation manual

superior pump 94505 owner's manual

superior pump

superior pump 94505 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.