54
5.4 PS/PM UltraSwitch™ nomenclature
4. CERTIFICATES
ATEX II 1G Ex ia IIC T4/T5/T6
IEC Ex ia IIC T4/T5/T6
ATEX II 2 G Ex e mb IIC T6
cFMus IS Class I,II,III Division 1 Group A,B,C,D,E,F,G
cFMus NI Class I Division 2 Group A,B,C,D; Class II Division 2 Group E,F,G; Class III Division 1&2
cCSAus Class I, Division 1 Groups A,B,C,D; Class II Division 1 Groups E,F,G; Classs III
cCSAus Class I, Division 2, Groups A,B,C,D; Class II, Division 2, Groups E,F,G; Class III
All certificates available for
download at www.pmv.nu
5. SPECIFICATIONS
5.1 Technical data
Ingress protection IP66 & Type 4x Weight 1 kg / 2.2 lbs
5.2 Materials of construction
Part Material
Housing/Cover PA6/PA66 Nylon 25% - 33% Glass Filled Engineered Resin
Shaft Stainless Steel
Cams/Splines Nylon
Terminal Block Nylon – Buchanan TBS Series
Internal Brackets Stainless Steel or Plated Steel
All Internal Fasteners Stainless Steel or Plated Steel
All External Fasteners Stainless Steel
All Molded in Fasteners Anodized Aluminum
UltraDome™ Polycarbonate
Rotor Polycarbonate
5.3 Type sign
Product name and model code
Warnings
Year of manufacture
S/N: XXXXXX
Manufacturer
Electrical rating
Serial number
Logotype
WARNING
POTENTIAL ELECTROSTATIC CHARGING HAZARD
SEE INSTRUCTIONS
POWER SOURCE MUST BE PROTECTED BY A FUSE
OF 3 A WITH BREAKING CAPACITY ≥ 1500A
Model code
Type sign for
Atex Ex e mb
PALMSTIERNA INTERNATIONAL AB, SOLNA, SWEDEN
S/N:
IP 66/Type 4X
DATE:
0470
Cl. I Div.2 Gr. A-D T6
Cl. I Div.2 Gr.A-D T4-6
Cl. II Div.2 Gr. E-G
Cl. I Div.1 Gr.A-D T5
Cl. II Div.1 Gr. E-G
Cl. III
NON INCENDIVE
Cl. II Div.2 Gr. E-G T6
II 1 G
11ATEX1065X
NEMKO
Ex ia IIC T4-T6 Gb
REFERENCE TO CONTROL DWG NO. RA-2 FOR SAFE USE
SAFTY AND SUITABILITY FOR DIVITION 2.
Div. 1,Gr A-G,T4-T6
CLASS I,II&III
INTRINSIC SAFY
SUBSTITUTION OF COMPONENTS MAY IMPAIR INSTRINS IC
Cl.III Div.1&2
WARNING:
POTENTIONAL ELECTROSTATIC CHARGING HAZARD- SEE
INSTRUCTIONS.
INTRINSIC SAFY
NON INCENDIVE
IECEx
NEM 11.0012X
*If the equipment is likely to come in contact with aggressive substances, it is the
responsibility of the user to take suitable precautions to prevent it from being
adversely affected, thus ensuring that the type of protection provided by the
equipment is not compromised.
A. Brand sticker P PMV
B. Shaft N NAMUR VDI/VDE 3845
D Double D 1/4”
C. Connections (cable entry) PS Engineered Resin Housing 1/2 NPT
PM Engineered Resin Housing M20x1,5
PN Engineered Resin Housing 3/4 NPT
PG Engineered Resin Housing M25x1,5
D. Number of cable entries 1 1 conduit
2 2 conduits
3 3 conduits
E. Indicator option 1 Flat cover without indicator
U Standard UltraDomeTM red/green
C 90 deg 3-way UltraDomeTM
D 180 deg 3-way UltraDomeTM
E 180 deg 3-way Centre-blocked UltraDomeTM
F 120 deg Thru/Divert UltraDomeTM
H Black/Yellow UltraDomeTM
K Ektar UltraDomeTM (red/green)
R Reverse UltraDomeTM (red=open / green=closed)
X 180 deg 3-way UltraDomeTM (white/blue)
F. Switch quantity 0 No Switches
2 2 Switches
4 4 Switches
G. Switch options options See page with switch options
H. Certificate 14 General Purpose
15 ATEX II 1G Ex ia IIC T4/T5/T6
21 IEC Ex ia IIC T4/T5/T6
22 ATEX II 2 G Ex e mb IIC T5/T6
27 FM IS Cl. l Div. 1 Grp. A, B, C, D; T4
28 FM NI, CSA NI Cl. l Div. 2 Grp. A, B, C, D, D
40 ATEX Ex ia, FM IS, CSA IS, IEC Ex ia
60 ATEX Ex ia, FM IS, CSA IS, IEC Ex ia, FM NI, CSA NI
I. Analog output 0 None
T 4-20 mA transmitter
D 180 deg 4-20 mA transmitter
A 0-1K Ohm Potentiometer
J. Wiring options 0 None
3 Brad Harrison Connectors - 7 pins
4 Weidmüller special AKZ 2,5
H Heavy Duty Terminal Block
K. Minimum extra terminals 2 2 Open Terminal Locations (Standard)
4 4 Open Terminal Locations (2 SPST switches)
6 6 Open Terminal Locations (2 SPDT switches)
8 8 Open Terminal Locations (2 or 4 SPST switches)
L. Special options 0 None
V Viton O-rings
FCD PMENIM0008-02 - 08/14 FCD PMENIM0008-02 - 08/14