Fluiteco SD User manual

SD
SLUDGE SCREW PRESS
FLUITECO reserves the right to make any change to its machines whenever the company feels that there is a
necessity to do so.
This manual is not to be sold to others for viewing without the written permission of FLUITECO.
REV 08
28/08/2019

2
This manual is an integral part of the supply of machinery, in the case it suffers damage and becomes unreadable in
any part, demand a copy to FLUITECO.
FLUITECO assumes no liability for the misuse of the machine and for any damage caused as a result of any
operation not covered or described in this manual.
The machine must be used only to meet the needs for which it was expressively designed, and any other use is
considered dangerous.
Every action that changes the structure and the operation cycle of the machine must be allowed explicitly only by the
technical department of FLUITECO.
Use only original parts; FLUITECO is not responsible for any damage following the use of non-original spare parts.
FLUITECO reserves the right to amend the draft and make marketable improvements without notifying customers
that already have similar models.
FLUITECO is responsible only for the descriptions in Italian and in case of difficulty of understanding contact our
office for clarification.
Warning!
This manual contains important information about safety procedures that must be
adopted for the use and maintenance of the machine: it is necessary that each operator
takes accurate view of such information before carrying out any work related to the
machine.

3
Index
GENERAL INFORMATION...................................................................................................................................................5
INTRODUCTION.............................................................................................................................................................5
HOW TO READ THE MANUAL........................................................................................................................................5
IDENTIFY THE UNIT........................................................................................................................................................6
CONFORMITY DECLARATION ........................................................................................................................................6
TECHNICAL SERVICE ......................................................................................................................................................6
SAFETY...........................................................................................................................................................................7
SAFETY LABEL POSITION................................................................................................................................................7
LIFTING AND INSTALLATION..............................................................................................................................................8
CHECKS AFTER RECEPTION............................................................................................................................................8
LIFTING AND POSITIONING ...........................................................................................................................................8
INSTALLATION AREA......................................................................................................................................................9
INSTALLATION..................................................................................................................................................................10
Fixing ...........................................................................................................................................................................10
ELECTRICAL CONNECTION...........................................................................................................................................11
Sludge Inlet-Outlet Connections .................................................................................................................................13
Hydraulic connection ..................................................................................................................................................14
SAFETY RULES ..................................................................................................................................................................14
NOT PERMISSIBLE USE ................................................................................................................................................14
SAFETY DEVICES OF THE PLANT ..................................................................................................................................16
RESIDUAL RISKS...........................................................................................................................................................17
DESCRIPTION AND SPECIFICATIONS................................................................................................................................19
SAFE AND CORRECT USE .............................................................................................................................................19
COMMANDS................................................................................................................................................................19
WORKING PRINCIPLE, NOT PERMISSIBLE WORKING PRINCIPLE ............................................................................19

4
TECHNICAL CHARACTERISTICS ....................................................................................................................................20
USE OF THE MACHINE .....................................................................................................................................................21
CHECKING AND STARTING ..........................................................................................................................................21
WASHING SYSTEM.......................................................................................................................................................22
PNEUMATIC COUNTERWEIGHT...................................................................................................................................23
MAINTENANCE ................................................................................................................................................................24
PRELIMINARY OPERATIONS FOR SAFETY ....................................................................................................................24
PERIODIC CHECKS........................................................................................................................................................24
OTHER INFORMATION.....................................................................................................................................................26
LONG TERM STORAGE.................................................................................................................................................26
DISMANTLING OF THE MACHINE................................................................................................................................26
HOW TO ORDER SPARE PARTS....................................................................................................................................26
Pneumatic actuator.....................................................................................................................................................27
SCREW CONVEYOR GEAR MOTOR ..............................................................................................................................28
WASHING GEAR MOTOR.............................................................................................................................................28
BREAKDOWNS.............................................................................................................................................................29

5
GENERAL INFORMATION
INTRODUCTION
Before starting with any operation, it is necessary to have read the manual very carefully , as to avoid any problem
and/or mistaken usage of the machine, which could potentially be dangerous for the objects and the employees in
proximity. The operation and instruction manual is part of the technical leaflets supplied with the machine and the
aim is to give all the information necessary for a safe and correct use of the machine.
The manual is addressed to the people in charge of the installation of the machine, to the ones in charge of the use
and for the maintenance.
HOW TO READ THE MANUAL
During the consultation of this manual it is possible to see some symbols and the meaning of these symbols is
explained in the following table:
GENERAL WARNING
This type of signal advises the personnel about the
dangers during the operation of the machine. If the
notice is not followed and the fundamental
carefulness is not applied, the machine could
potentially put the employees in danger.
NOTICE OF DANGER
BECAUSE OF THE
PRESENCE OF ELECTRIC
TENSION ON THE
MACHINE
This type of notice informs about the presence of
tension. Before starting with regular/special
maintenance, it is necessary to stop the electric
tension by turning off the general switch. After
that it is necessary to be sure that tension is
totally absent.
WARNING
This type of notice advises about the necessity to give
particular attention.

6
HOW TO IDENTIFY THE UNIT
The machine can be identified by the descriptions on the metallic Plate here represented. The Plate is easily
recognizable on the metallic frame of the unit.
On the Name plate it is possible to find the following
details:
1) Name and address of the manufacturer
2) Machine model
3) Serial number
4) Years of manufacturing
5) Weight
6) Power
7) Tension of the motor
Plate data cannot be modified.
In the case of necessity, when contacting our after sales service, please provide us with the serial number of the
machine as to quickly identify it.
CONFORMITY DECLARATION
The machine is manufactured according to the directive 2006/42/CE. The machine is destined to be part of a plant
that will be responsibility of the installer.
Attached with the present manual is reported the Conformity Declaration provided for the directive 2006/42/CE.
TECHNICAL SERVICE
To obtain the best performance from the machine and to avoid any possible problem that could cause the
termination of the warranty it is necessary to follow all the indications of such operation and maintenance manual.
This operation and maintenance manual is part of the machine and it must be easily reachable by all the personnel in
charge.
In case of necessity to contact FLUITECO, even after reading the instruction, it is necessary to have this manual close
at hand, to have a better understanding of all the explanations.

7
Please always remember to inform our Service about the serial number of the machine. The serial number is always
reported on the Plate of the machine.
SAFETY
This machine has been designed and constructed according to the applicable regulations for prevention of
accidents in reference both to the mechanical and electrical parts. The safety systems of which it is equipped have
the function to protect the operator and the machine itself during the working phases.
Where it has not been possible to eliminate potentially dangerous situations, these have been reported by
appropriate labels or labels applied in the surrounding of the installation area. Periodically check that they are
present and in good condition.
SAFETY LABEL POSITION
On the machine some labels are applied to indicate the points of residual risks for the user or important points of the
machine.
You must ensure that these do not deteriorate over time or come off.
If you encounter this situation, please contact our support department for you to ship the damaged or missing labels to
reapply when originally planned.

8
LIFTING AND INSTALLATION
CHECKS AFTER RECEPTION
When receiving the machine it is necessary to check if the type and the quantities are as per order confirmation. It is
necessary to verify also that the machine is complete in all the parts as per the transport document.
Before unloading, please check that the machine was not damaged during the transport. In case of damages, it is
necessary to make a short description on the transport document.
LIFTING AND POSITIONING
Lifting and positioning of the machine can be done by means of suitable lifting system for the weight and dimension
(for the weight of the machine, please check the weight present on the Name plate). In case of machine supplied in a
wood cage, please take note also about its weight.
The lifting of the machine must be always done using suitable lifting eyebolts fixed on the machine. Always use them
for transportation using hooks with safety fasteners.
Always lift and move the machine using only the eyebolts positioned on the machine.
Lifting Points Lifting Points
Lifting Points
Picture 1: Lifting of the machine by means of hooks put in the appropriate lifting eyebolts

9
It is forbidden to use clamps, rings, open hooks or other system that does not guarantee the safety
in the lifting operation.
The lifting and positioning operation must be executed only by competent personnel. it is forbidden to remove the
hooks from the eyelets while transporting the machine.
WARNING
The employee in charge of the lifting and positioning of the machine must operate with maximum attention to avoid
any damage to the goods or any person in proximity. Nobody can remain under the area where the machine is
hanging.
Check the efficiency of the lifting system to avoid damage to the operator or the ones surrounding the area.
It is forbidden to use a lifting chain that can damage the surface of the machine. If the chain will damage the
surface of the steel, it is necessary to make again the surface treatment of passivation.
Transport packing must be removed only near the installation area (machine is supplied without packing in the
standard version).
INSTALLATION AREA
The area destined for the positioning of the machine must be provided by the user with all the connections (electric
power, air, etc..) for the operation of the machine, in conformity with the information of the present manual, and in
conformity with the characteristics of the electric and electronic components. It is responsibility of the user that the
positioning area are in line with the local laws and safety rules: aeration, ground lead, appropriate illumination, etc...
In particular places with cold weather, machines without insulation (optional), can be used only inside a proper
building. Ice inside extraction screw conveyor can cause damages on the gearmotor or in the solids outlet.

10
It is responsibility of the user to preview the positioning area with the safety devices
as per the present manual.
INSTALLATION
During installation it is necessary to think beforehand about the proper movement space around the
machine to do the maintenance service safely.
FIXING
The installation area must be appropriate for the weight and the dimensions of the machine. The fixing of the unit
must be done by an installer through suitable fixing screws, put in correspondence of the scheduled fixing points,
located as in the following picture.
Picture 2: Position of the fixing points
Fixing Points
Fixing Points

11
A bad fixation could cause damage to the employees and to the objects surrounding the machine. It is necessary
to follow very carefully the instructions of this manual and verify all of the bolts’fixation and the stability of the
whole structure.
The machine must be positioned without any inclination change in respect to the inclination projected during
construction.
ELECTRICAL CONNECTION
Machine is supplied with standard electric components for the normal operation of the machine:
1. Screw electric motor
2. Washing electric motor
3. Solenoid valves of the washing system
4. Electronic torque limit switch (optional)
It is responsibility of the user to provide the electric panel and its installation and connection to the machine,
following international laws and local rules.
Electric work must be executed only by a specialized worker.
Electric motor, solenoid valves and electronic torque limit switch connections must be accomplished by the installer
and they must be executed following each manufacturer’s manual attached to the present manual.
The manufacturing and placement of the electric panel is under the responsibility of the installer. We recommend
you are very thorough with the appropriate protection against excessive adsorption of the electric motor. It is further
compulsory to foresee the no possibility of the automatic re-start of the machine in case of interruption and restore
of the electric current.

12
WARNINGS:
Electric work must be executed only by a specialized employee.
Check that the voltage is the same as per the name plate present on the electric motor.
Electric cables must have the correct dimensions as requested by the
electric motor.
It is forbidden to work on the electric motor when it is in tension.
During the electrical connection, the principal electric power line must be disconnected and the work must be
executed only by specialized workers following international and local laws and rules.
Electric cables must be protected considering the installation area and placed to avoid obstruction on the
operation of the machine, following specific applicable rules.
It is forbidden to introduce the hands inside the screw in operation.
Any component of the machine can be used as support to go up the machine!

13
SLUDGE INLET-OUTLET CONNECTIONS
Inlet
Dimensions
Description
D
2”- 3” for
SD900
Sludge inlet MAX SLUDGE INLET PRESSURE 0,8 Bar
E
Ф60,3 mm
SD200
Sludge dewatering water outlet
Ф88,9 mm
SD400
Ф101,3 mm
SD700
F
Dewatered sludge outlet
E
D
F
C

14
HYDRAULIC CONNECTION
SD-Sludge screw press is supplied with one washing connection 1”.
Solenoid valve represents an optional.
SAFETY RULES
NOT PERMISSIBLE USE
The machine is provided with all safety devices, but due to the functioning of it, there is a part that can be protected
only inside the plant where the machine is installed (please check the figure hereunder).
This indispensable protection is rensponsibility of the installer.
Picture 3: Dangerous zones for the machine depending on the installation
OUTLET ZONE

15
We recommend to protect these areas using devices with an immediate switch off instrument (an emergency
button), in case of unsafe access (electric power block). We recommend the positioning of proper warning signals
near the indicated areas.
WARNINGS:
Never put hands, objects etc… inside the solid’s outlet. A notice must be fixed near the outlet to inform the
personnel.
To avoid any accident, it is necessary to read carefully the following information:
•The machine can be used only by qualified and expert personnel.
•All the connections must be executed from qualified and expert personnel.
•Execute a correct fixing among the different components and a correct fixing to the floor.
•When the machine is running, all the personnel must remain at a safe distance.
•Before starting the machine, it is necessary that all the safety devices are connected, working and that the
machine is in perfect conditions.
•In case of defects, in particular of the safety devices, the operator must inform immediately his superiors,
the safety manager and the operator of the next shift.
•If the defect prevents the machine from a safe use, the machine must be immediately stopped.
•If during the working shift more people are in charge, before making any operation it is necessary to inform
also the other collegues.
•The machine can be used only for the use it was designed to (see 4.1).
•Every modification regarding the use or the safety conditions can be executed only from FLUITECO
personnel, and following this, FLUITECO refuses every responsibility for unauthorized modifications or
damages caused from these chenges.
•It is forbidden to remove safety devices present in the machine.
•All checks, maintenance etc…, can be executed only by qualified and expert personnel.

16
•Personnel in charge must use a proper workwear. It is necessary to ask for this workwear (gloves, shoes, …)
to the safety manager.
•Disconnect electric power before making any operation and/or maintenance to the machine.
•To avoid any accidental startup of the machine during inspections, cleanings and maintenance, it is necessary
to turn the general switch on the position OFF and push the emergency button to block the machine.
•Before starting the machine it is necessary to be sure that all the safety devices are active.
FLUITECO srl refuses every responsibility for damage to people and objects caused form the absence and/or
tampering of the safety devices (notices and protections).
It is necessary to make inspection of the plant minimum once per day, or once each working shift to check possible
damages or defects that can be seen from outside.
In case of any anomaly, stop immediately the plant, in particular if there are risks for your safety or the safety of
the plant.
Be sure that safety devices, safety notices and the identifying plate of the plant are always clearly readable.
the connection to the floor of the external metallic part of the machine is compulsory.
It is forbidden to remove safety and warning notices.
It is forbidden to start the work with safety devices opened or to open them during the working.
Touching the rotating part of the machine could cause serious injuries.
Never introduce hands inside the outlet of the compaction zone.
SAFETY DEVICES OF THE PLANT
Every plant must be provided, by the installer, with an emergency button (red color) to stop the plant. Pushing this
button in particularrly dangerous conditions the plant must stop immediately.

17
The emergency button must be located near the machine and it must be easily approachable.
Safety devices include:
•Enclosures, covers or automatic protection of the screen zone
•Protection covers of the electric motor’s fan
•Gearmotor shaft protection cover
it is responsibility of the installer to assure the presence of all protections necessary to grant a safe use of the plant
both in phase of use and maintenance.
RESIDUAL RISKS
FLUITECO srl has produced and built the machine specifically trying to reduce the risks as much as possible.
Some risks related to the incorrect maintenance process otherwise are impossible to be deleted during the designing
phase and realization of the machine. Other sources of risk are represented from behaviors that are not
corresponding to what this manual is explaining and also at the missing respect of Laws and Standards related to
accident prevention and safety at work.
This following table summarizes the risks and the behaviors to avoid them.
Picture
Description
Measures
The machine has moving parts that can cause
injury
It is forbidden to do maintenance when the
machine is in motion.
Prevent access to the channel discharge while
the machine is working (with railings, fences,
interlocking openings).
The machine must be equipped with its own
electrical system: by removing the covers of
the motor terminal you can access to the
electrical parts
Put the machine on safety mode before every
operation.
Only specialized personnel can access to the
parts electrically connected. The electric part of

18
the machine built by the installer must be
according to EN 60204-1.
Hot surfaces: some mechanical objects placed
inside the machine can reach a temperature
higher than 60° degree in case of malfunction
Wait for the gear to reach room temperature.

19
DESCRIPTION AND SPECIFICATIONS
SAFE AND CORRECT USE
The SD unit realizes the dewatering of the sludge in small/medium sized plants. This machine, fabricated in stainless
steel, takes advantage of a patented thickening principle and of a mechanical dewatering principle. The liquid sludge
(solid concentration 0,8 - 5 %) is gathered until a solid content variable from 15 to 30% is reached (depending from
the kind of sludge, reactants and application field).
The sludge added to the reactant is introduced to the machine. A pre-thickener static mixer provides a first
thickening action. Then the screw transports the sludge in the dewatering zone where the action of mechanical
dewatering is emphasized.
Every other use of the machine will cause the termination of the warranty and will release FLUITECO from every
responsibility.
IMPORTANT:
SD Screw Press gives the performance required if the following conditions are totally satisfied:
1- The sludge to dewater is suitable to be dewatered with the sludge screw press.
2- The sludge is conditioned with polyelectrolyte to obtain the correct flocculation in term of size and consistency of the
flocs.
3- In the case Fluiteco supplied only the SD Screw Press without all others items of the sludge dewatering plant, including
Polyelectrolyte preparation and dosing system and sludge/polyelectrolyte mixing system, Fluiteco will respond only on
eventual mechanical defect of the SD sludge screw press and not about the performance of the SD screw press in term
of flow rate capacity, dryness performance and solids recovery performance,
Before switching off and restarting the machine it is necessary to proceed SISTEMATICALLY with a complete
washing cycle of the screen basket.
COMMANDS
The handling of the plant must take place automatically with the activation of the sludge feed pump.
WORKING PRINCIPLE, NOT PERMISSIBLE WORKING PRINCIPLE
The functioning of the machine is compromised if the solid matters:
•cannot be mechanically separated from the transporting liquid;
•agglomerate with themselves or with other parts of the machine;
•they compact theirselves or if they attach to the machine.
•did not receive an effective chemical-biological pretreatment up stream.

20
TECHNICAL CHARACTERISTICS
Here following the principal characteristics and dimensions of the main models SD produced by FLUITECO
PERFORMANCE CHARACTERISTICS
THE DATA HERE ABOVE IS INDICATIVE. PLEASE MAKE REFERENCE TO THE SPECIFIC DATA GIVEN WITH OUR SPECIFIC
TECHNICAL/ECONOMIC OFFER
AIR NOISE EMISSION: Level of acoustic pressure pondered (LpA doesn’t exceed the 70 dB )
Table of contents
Other Fluiteco Water Filtration System manuals
Popular Water Filtration System manuals by other brands

THERMEx
THERMEx Water filter Installation and user instructions

Microline
Microline T.F.C. - 435 Installation, operation & service manual

Dixon Pumps
Dixon Pumps FS1 DOLLY Series Installation, operation and maintenance instructions

HotSpring
HotSpring ACE owner's manual

Fass
Fass T 095G installation manual

HYDAC International
HYDAC International BDE Spare parts list

Tol Watertechniek
Tol Watertechniek Purusaqua TRO manual

MAUNAWAI
MAUNAWAI PI CONNECT PiTec 2in1 manual

Frizzlife
Frizzlife G Series owner's manual

Clean Water Systems
Clean Water Systems Greensand 7500 Installation & start?up guide

Ozone
Ozone SC-OZ owner's manual

Watts
Watts OneFlow+ OFPSYS Installation, operation and maintenance manual