Fluke Amprobe UAT-620 Instruction manual

TECHNICAL DATA
Amprobe UAT-620 Underground Utilities Locator Kit
Key features
Rated CAT IV 600 V, ensuring safety when working with energized cables
Multiple tracing modes allow you to locate and trace energized and de-energized utilities
Depth measurement up to 20 ft
Receiver’s high-contrast display allows for clear viewing in full sunlight and features an automatic backlight for shaded
and dark area
Product overview: Amprobe UAT-620 Underground Utilities Locator
Kit
Accidentally hitting a utility line during a project can lead to costly repairs and create hazardous public safety situations.
Digging in the wrong place can also lead to unnecessary delays and costs for your project, and ultimately, your company.
Avoid this disruption with the rugged and durable Amprobe UAT-600 Series, designed to accurately pinpoint underground
utilities and buried services up to 100 feet deep with accurate depth measurement to 20 feet.
The locating kit comes complete and ready for use with a Transmitter, Receiver, test lead kit, batteries and additional fuses,
all in a mobile, protective duffle bag. Also included is a Signal Clamp for transmitting a signal when it is not possible to make
electrical contact with the cable to be traced. For applications where ground fault locating is required, use the UAT-600
Transmitter in combination with the optional A-Frame accessory.
Main applications
Locate energized 50/60 Hz cables carrying current
Identify the location of all metallic utilities: pipes*, energized and de-energized cables

2 Fluke Corporation Amprobe UAT-620 Underground Utilities Locator Kit
https://www.fluke.com/en-us/product/building-infrastructure/wire-tracers/uat-620
Trace individual pipes* or cables (energized or de-energized)
*Tracing of non-metallic pipes and conduits is possible after inserting metal fish tape or cable
Three testing modes for wide range of applications
Passive power mode (50/60 Hz) – tracing energized lines conducting current (no Transmitter necessary)
Passive radio mode (RF) – using surrounding radio waves to trace underground utilities (no Transmitter necessary)
Active mode using UAT-600-T Transmitter
Three active modes using the UAT-600-T Transmitter
Induction – the Transmitter will automatically start to radiate a signal around it using an internal antenna, used for tracing
individual cables where there is no access to the line to connect test leads or a clamp
Direct connection with test leads – the most reliable method to trace individual cable or a pipe
Clamp (Included in the UAT-620 kit, optional for the UAT-610 kit) – provides an efficient and safe method of applying a
locate signal to a cable, where it is not possible/safe to gain access to a cable for making an electrical contact
Special applications
2 frequency options: 8 kHz and 33 kHz
Locate non-metallic pipes and sewer lines
Take depth and current measurements
Measure voltage, resistance and output current
Advanced locating with two people
Locate ground faults with the optional AF-600 A-Frame accessory
Unparalleled safety
Stop compromising time and safety. What truly sets the UAT-600 Series apart from other underground locators is its CAT IV
600 V safety rating. This allows you to safely connect the Transmitter directly to an energized line up to 600 V in a CAT IV
environment. Previously, if a crew needed to trace a specific electrical line by transmitting a signal through it, the line had to
be de-energized first, adding time and reducing productivity.
Specifications: Amprobe UAT-620 Underground Utilities Locator Kit
Features UAT-600-R Receiver UAT-600-T Transmitter
SC-600 Signal
Clamp (included
with UAT-620,
optional for
UAT-610)
Measurement category CAT IV 600 V
Operating voltage/current 0 to 600 V 0 to 600 V, 100 A
max.

3 Fluke Corporation Amprobe UAT-620 Underground Utilities Locator Kit
https://www.fluke.com/en-us/product/building-infrastructure/wire-tracers/uat-620
Features UAT-600-R Receiver UAT-600-T Transmitter
SC-600 Signal
Clamp (included
with UAT-620,
optional for
UAT-610)
Operating frequency/tracing modes
Active tracing: 33 kHz and
8 kHz
Passive tracing: 50/60 Hz
and Radio
Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8
kHz and 33 kHz
Clamp mode: 8 kHz and 33
kHz
De-Energized circuit
Induction mode: 33 kHz
Direct connection modes: 8
kHz, 33 kHz, A-Lo/A-Hi
A-Frame: 8 kHz
Clamp mode: 8 kHz and 33
kHz
33 kHz and 8 kHz
Locating modes Peak and Null - -
Depth measurement and accuracy
Up to 20 ft
4 in to 10 ft: pm; 3 %
10 ft to 20 ft: pm; 5 %
- -
Display backlight Automatic Yes -
Audio indication Increasing closer to the
signal
Fast beeps showing the better
signal is applied -
Transmitting mode power output - Max. 3 watts -
Output voltage - Max. 50 V rms -
Output current - Max. 250 mA rms, constant
current in 5 steps -
Output current - - 23 V rms at 8 kHz
30 V rms at 33 kHz
Mains voltage measurement -
0 V to 600 V, 50 Hz to 60 Hz
Resolution: 1 V
Accuracy: pm; 10%
-
Resistance measurement (De-
energized circuit) -
0 ohm; to 999 k ohm;
Range: 0 ohm; to 999 ohm;
(resolution: 5 ohm;)
Range: 1 k ohm; to 999 k ohm;
(resolution: 1 k ohm;)
Accuracy: pm; 10%
-
Output hazardous voltage warning - ≥ 30 V rms -
Mains hazardous voltage warning - ≥ 30 V rms -
Sensitivity adjustment (gain control) Yes - -
Sensitivity at 1 m (typical)
Power: 2 mA
Radio: 20 μA
8 kHz: 5 μA
33 kHz: 5 μA
- -
Display
4.3 in, 320 x 240 BW
outdoor LCD display with
auto backlight
LCD display (LED backlight)
2.4 in x 1.3 in -

4 Fluke Corporation Amprobe UAT-620 Underground Utilities Locator Kit
https://www.fluke.com/en-us/product/building-infrastructure/wire-tracers/uat-620
Features UAT-600-R Receiver UAT-600-T Transmitter
SC-600 Signal
Clamp (included
with UAT-620,
optional for
UAT-610)
Update rate Instantaneous
Current (mA): 10 ms
Voltage (V): 15 ms
Resistance ( ohm;): 330 ms
-
Operating temperature and humidity -4 °F to 122 °F (-20 °C to 50 °C), ≤90% RH
Storage temperature and humidity -40 °F to 140 °F (-40 °C to 60 °C), ≤90% RH
Operating altitude < 6561 ft (< 2000 m)
Water and dust resistance IP54
Drop proof 3.28 ft (1 m)
Power supply (6) 1.5 V AA alkaline
batteries
(8) 1.5 V D cell alkaline
batteries -
Auto power off 15 minutes idle - -
Battery life Approx. 35 hours at 70 °F
(21 °C) (Typical)
Approx. 16 hours at 70 °F (21
°C) (Typical) -
Overload protection -
600 V rms
Fuse FF 500 mA, 1000 V, IR
30 kA, Φ6.3×32 mm
-
Safety compliance
IEC 61010-1, IEC
61010-2-033
CSA/UL 61010-1, CSA/UL
61010-2-033
IEC 61010-1, IEC 61010-2-033
CSA/UL 61010-1, CSA/UL
61010-2-033
IEC 61010-031, CSA/UL
61010-031 (test leads)
IEC 61010-1, IEC
61010-2-033
CSA/UL 61010-1,
CSA/UL 61010-2-033
Size (H x W x L) Approx. 11.9 x 4.7 x 30.7 in
(302 x 120 x 779 mm)
Approx. 14 x 9 x 4.7 in (355 x
230 x 120 mm)
Approx. 11.6 x 7.1 x
1.4 in (295 x 180 x
37 mm)
Weight Approx. 4.2 lb (1.9 kg)
(batteries installed)
Approx. 7.0 lb (3.2 kg)
(batteries installed)
Approx. 1.9 lb (0.85
kg)

5 Fluke Corporation Amprobe UAT-620 Underground Utilities Locator Kit
https://www.fluke.com/en-us/product/building-infrastructure/wire-tracers/uat-620
Ordering information
Amprobe UAT-620 Underground Utilities Locator Kit
Includes:
UAT-600-R Receiver
UAT-600-T Transmitter
CC-UAT-600 Carrying Case
TL-UAT-600 Test Leads Kit (black test lead with detachable black alligator clip, red test lead with permanently attached red
alligator clip, ground stake)
2 x FP-UAT-600 Replacement Fuses
SC-600 Signal Clamp
6 x AA Batteries
8 x D Batteries
User Manual and Quick Reference Guide

Fluke.
Keeping your world up and running.®
Fluke Corporation
PO Box 9090, Everett, WA 98206 U.S.A.
For more information call:
In the U.S.A. (800) 443-5853
In Canada (800) 36-FLUKE
From other countries +1 (425) 446-5500
www.fluke.com
©2022 Fluke Corporation.
Specifications subject to change without notice.
12/2022
Modification of this document is not permitted
without written permission from Fluke Corporation.
6 Fluke Corporation Amprobe UAT-620 Underground Utilities Locator Kit
https://www.fluke.com/en-us/product/building-infrastructure/wire-tracers/uat-620
Table of contents
Other Fluke Security Sensor manuals

Fluke
Fluke ClirVu CV200 User manual

Fluke
Fluke 26500090 Instruction manual

Fluke
Fluke TS 90 User manual

Fluke
Fluke LDR User manual

Fluke
Fluke PLS XLD User manual

Fluke
Fluke PRUFTECHNIK DBS30 User manual

Fluke
Fluke PLS SLDR User manual

Fluke
Fluke FiberInspector Pro FI-7000 User manual

Fluke
Fluke C9970 User manual

Fluke
Fluke TNT 12000 DoseMate User manual