12m WIDE ANGLE WIRELESS PIR
The 4190-GB is a Grade 1 wireless PIR, for operation with 4000 series wireless control panels.
This unit employs the FM wide angle pet lens.
INHIBIT To prevent repeated transmissions and resultant battery drain, the PIR incorporates a 2
minute inhibit timer. When movement is detected the alarm is transmitted and then further
transmissions are inhibited for 2 minutes or until the PIR has seen no movement for two minutes.
PULSE COUNT The recommended setting is pulse count 2. For maximum detection sensitivity, if
required, no pulse count can be used.
RECOMMENDED BATTERIES Two AA size Alkaline batteries are required, Eveready or Duracell
are recommended. (Available from FM Electronics)
MOUNTING Always mount the detector at a height of 2.2 meters so that anyone entering the area
passes across the detection beams.
TILT ADJUSTMENT The Lens must be set precisely central, to prevent the main beams from
looking down.
If the ground is sloping the detector should be set to the same slope angle. This can be
accomplished by loosening the two lens fixing screws and sliding the lens fully up to tilt upwards 4
degrees or lens fully down to tilt the beams downwards 4 degrees.
(Refer to the separate graphs overleaf if the ground is sloping.)
4190-GB
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Plan View
WALK TEST BUTTON has two functions:
1. When pressed for one second sends a Learn transmission to the control panel,
enabling the device to be learned in and RSSI measurements taken.
2. Provides a user walk test facility for two minutes.
Press for
walk test
& Learn
transmis-
sion
PROGRAM LINKS
NO LINKS FITTED - Pulse count =2
LINK 3FITTED - No pulse count
LINK 2 FITTED - Pulse count = 4
LINK 1FITTED - Overrides the 2 minute inhibit. With this link fitted the PIR will
transmit again after 2 minutes with continuous movement
present. Link 1 s unaffected by links two or three
ADDING A DETECTOR TO ANY FM4000 SERIES CONTROL PANEL OR FM4040 INTERFACE
1. Connect the batteries. The detector will take approx. 5 minutes to settle. So although you can
program it, the PIR will not detect movement for the initial 5 minutes & until 2 or more minutes of
no movement have been detected in normal operation.
2. Enter the engineers program by keying in 4679 or your engineers code. (The alarm LED will
illuminate to indicate that you are in engineer mode).
3. Key in the number of the zone to which the detector is to be allocated. i.e. 01 for zone 1. 08 for
zone 8.
3a FM4000EN, FM4000X & FM4000Xtra only.
Select the device number you wish to learn onto the zone, i.e. press 1 for the first device, press 2
for the second device etc.. Up to 8 devices may be added to a single zone.
(These panels require 3 digits to learn a detector onto them: Zero, Zone number then
device number. ie ZONE 1 Detector 1 is 011)
4. Press the walk test & Learn button on the pir. The control panel will bleep twice a zone LED will
illuminate to indicate that one more detector is programmed onto that zone.
5. Press the Full Set key to accept.
6. Key in 48 to exit engineer programming.
Lens adjust
screws
Program links
Normal PCB central
CI-220 ISSUE 3
Tilting the detector
0.0
5.0
10.0
15.0
20.0
25.0
30.0
35.0
40.0
45.0
50.0
55.0
60.0
65.0
70.0
75.0
80.0
85.0
90.0
95.0
100.0
0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Angle degrees
Packing dimension (mm)
Checking the ground slope angle at 20m
0
2
4
6
8
10
12
14
16
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Rise / Fall 20 metres from the detector (m)
Angle (deg.)
Checking the ground slope angle at 10m
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5
Rise / Fall 10 metres from the detector (m)
Angle (deg.)
ESTABLISHING THE ANGLE OF GROUND SLOPE
If the ground is not level, the detector will need to be tilted at the same angle.
The graph below gives the angle of the ground slope by measuring the rise
(or fall) 10 metres and 20m from the detector.
Packing dimension for a specific angle is given in the following graph.
10.8
Packing dimension
South Walk, Vantage Point Business Village, Mitcheldean, Gloucestershire,
GL17 0DD Tel. 01594 827070 email. [email protected]
www.fmelectronics.co.uk
FM Electronics is the Manufacturing division of FM Security Ltd

Popular Accessories manuals by other brands

kinetic inRide 3.0 Installation guides

kinetic

kinetic inRide 3.0 Installation guides

PCB Piezotronics 079B21 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 079B21 Installation and operating manual

weinor WGM Sottezza Instructions for maintenance and use

weinor

weinor WGM Sottezza Instructions for maintenance and use

CNP Brands 121340-002 manual

CNP Brands

CNP Brands 121340-002 manual

schmersal BNS 16-12ZD operating instructions

schmersal

schmersal BNS 16-12ZD operating instructions

Sling Pitcher SP Operation manual

Sling Pitcher

Sling Pitcher SP Operation manual

U-Line H-7127 manual

U-Line

U-Line H-7127 manual

Elsner KNX RW Installation and adjustment

Elsner

Elsner KNX RW Installation and adjustment

Philips DLA66067D brochure

Philips

Philips DLA66067D brochure

Carlon RC3304F Instruction guide

Carlon

Carlon RC3304F Instruction guide

Lightolier 1002P1 specification

Lightolier

Lightolier 1002P1 specification

Huawei iSiteC BTS3601C installation manual

Huawei

Huawei iSiteC BTS3601C installation manual

Sanela SLW 02GT Instructions for use

Sanela

Sanela SLW 02GT Instructions for use

Galaxy Crescent manual

Galaxy

Galaxy Crescent manual

turck FCS-G1/2HC4-NAEX0/L065 manual

turck

turck FCS-G1/2HC4-NAEX0/L065 manual

Promate polyMax-8 user guide

Promate

Promate polyMax-8 user guide

Apogee Apogee Duet user guide

Apogee

Apogee Apogee Duet user guide

Velleman K8067 Illustrated assembly manual

Velleman

Velleman K8067 Illustrated assembly manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.