Dear System Owner:
Thank you for purchasing the TD-3124 Blood Pressure Monitoring System. This
manual provides important information to help you operate this system
properly. Before using this product, please read the following contents
thoroughly and carefully.
With the compact size and easy operation of this TD-3124 Blood Pressure
Monitoring System, you can easily monitor your blood pressure by yourself at
any time or place. In addition, this system can help you and your healthcare
professionals to monitor and adjust your treatment plans, and keep your blood
pressure under control.
If you have other questions regarding this product, please contact the place of
purchase.
Owner’s Manual
Version 1.0
2015-06
BLOOD PRESSURE
MONITORING SYSTEM
TD-3124 READ BEFORE USE
1. Use this device ONLY for the intended use described in this manual.
2. Do NOT use accessories which are not specied by the manufacturer.
3. Do NOT use the device if it is not working properly or damaged.
4. Do NOT use under any circumstances on newborns or infants.
5. This device does NOT serve as a cure for any symptoms or diseases. The data
measured are for reference only. Always consult your doctor to have the results
interpreted.
6. Keep the equipment and its exible cord away from hot surfaces.
7. Do NOT apply the cu to areas other than the place directed.
8. Use of this instrument in a dry environment, especially if synthetic materials
are present (synthetic clothing, carpets etc.) may cause damaging static
discharges that may cause erroneous results.
9. Do not use this instrument in close proximity to sources of strong
electromagnetic radiation, as these may interfere with the accurate operation.
KEEP THESE INSTRUCTIONS IN A SAFE PLACE
Your meter stores the 100 most recent blood pressure test results in the meter
memory. To recall the memory, start with the meter off.
Battery
Your meter comes with four (4) 1.5V AA size alkaline batteries.
1. Press . All the LCD symbols and the last blood
pressure result will appear. Then the cuff will begin
to inflate automatically.
2. The heart symbol “ ” will flash when pulse is
detected during the inflation.
4. Press to switch off. Or it will switch off
automatically after being idle for 3 minutes.
1. Press and release .
will appear on the display. Press again, and
the first reading you see is the last test result.
The symbol appears with E-b:
The power is not enough to do a test. You must change
the batteries immediately.
To replace the batteries, make sure the meter is turned off.
1. Press the edge of the battery cover and lift it up to remove.
2. Remove the old batteries and replace with four 1.5V AA size alkaline batteries.
3. Close the battery cover. If the batteries are inserted correctly, you will hear a
“beep”afterwards.
2. Press to recall the next test results stored in the
meter each time you press.
3. Exit the memory.
Keep pressing and the meter will turn off.
Intended Use
The TD-3124 system is a system designed to measure blood pressure
non-invasively. It is intended for use at home and in clinical settings. The device is
not to be used for the diagnosis or screening of hypertension or for testing on
newborns.
Test Principle
Blood pressure is measured non-invasively at the arm based on oscillometric method.
This device is NOT able to take measurements in the presence of common
arrhythmia, such as atrial or ventricular premature beats or atrial brillation. It
may produce reading error.
WARNING:
• If you press during measurement, the monitor will be turned o.
• If the pulse rate symbol is shown as“ ” instead of “ ”, this indicates
that the meter has detected an irregular heart beat.
NOTE:
• Replacing the batteries does not aect the test results stored in memory.
• As with all small batteries, these batteries should be kept away from small
children. If swallowed, promptly seek medical assistance.
IMPORTANT SAFETY PRECAUTIONS
BEFORE YOU BEGIN
TAKING MEASUREMENTS
MONITOR MEMORY (only for TD-3124B)
MAINTENANCE
1
2
3
Display Screen
ON/OFF Button
Air jack
DC Adapter Port
Connect to a power supply
1
2
3
4
5
6
7
8
M Button
Enter the meter memory
Pressure Cu
Air Tube
Air Plug
Connect to air jack
Meter Overview
TD-3124A TD-3124B
Reviewing Test Results
Low Battery Signal
Replacing the Battery
1
2
3
5
4
6
7
8
Dealer’s portion
Name of product:
Name of owner:
Address:
Tel No: (Mobile) (H) (O)
Email: Age: Gender: M F
Test Result
Memory Mode Symbol
Low Battery Symbol
Pusle Rate Symbol
Pusle Rate
1
2
3
4
5
Display Screen
1
4
5
2
3
• Avoid caeine, tea, alcohol and tobacco for at least 30 minutes before
measurement.
• Wait 30 minutes after exercising or bathing before measurement.
• Sit or lie down for at least 10 minutes before measurement.
• Do not measure when feeling anxious or tense.
• Take a 5-10 minute break between measurements. This break can be longer if
necessary, depending on your physical condition.
• Keep the records for your doctor as reference.
• Blood pressure naturally varies between each arm. Always measure your blood
pressure on the same arm.
1. Connect the air plug of the tubing to the air jack of
the meter.
2. Assemble the cuff as shown on the right. The smooth
surface should be inside of the cuff loop and the
metal D-ring should not touch your skin.
3. Stretch your left (right) arm in front of you with your
palm facing up. Slide and place the cuff onto your
arm to let the air tube and artery mark region (in red)
toward the lower arm.
Wrap and tighten the cuff above your elbow. The red
line on the edge of the cuff should be approximately
0.8” to 1.2” (2 cm to 3 cm) above your elbow. Align
the tube over the main arteries on the inside.
4. Leave a little free space between the arm and the
cuff; you should be able to fit two fingers between
them. Clothing must not restrict the arm. Remove all
clothing covering or constricting the measurement
arm.
5. Press the hook material firmly against the pile
material. The top and bottom edges of the cuff
should be tightened evenly around your upper arm.
1. Sit down for at least 10 minutes before measuring.
2. Place your elbow on a flat surface. Relax your hand
with the palm facing up.
3. Make sure the cuff is about the same height as the
location of your heart. Press . Remain still and do
not talk or move during the measurement.
4. Measurement is in progress.
After the meter is turned on, the cuff will begin to inflate automatically.
WARNING:
If the cu is relatively lower (higher) than the heart, the obtained blood pressure
value could be higher (lower) than the actual value. A 15 cm dierence in height
may result in an error around 10 mmHg.
TESTING YOUR BLOOD PRESSURE
Before Measurement
Fitting the Cu Properly
Proper Measurement Position
2~3cm
INDEX
RED LINESHOULD BE AT THE INSID
INDEX MUST
The range index of cu should
fall within this range
3. After the measurement, the meter displays the
systolic pressure, diastolic pressure and pulse rate.
YEAR
WARRANTY
Owner’s portion
Name of product:
Name of owner:
Address:
Tel No: (Mobile) (H) (O)
Email: Age: Gender: M F
Always apply the pressure cuff before turning on the meter.
311-3124200-006
To start a single NIBP
measurement
NOTE:
• To delete ALL the results, press and rmly hold for
4 seconds until "dEL" displays.
Release , “CLr ALL”and " " are displayed on the
meter, which indicates that all results have been
deleted.
.Any time you wish to exit the memory, press or
leave it without any action for 3 minutes. The meter
will switch o automatically.
.If using the meter for the rst time, you will only see
the " " symbol on the display when you recall the
test results. It indicates that there is no test result in
the memory.

This device has been tested to meet the electrical and safety requirements of:
IEC/EN 60601-1, IEC/EN 60601-1-2.
Reference to Standards:
• EN 1060-1 /-3, NIBP-requirements
• IEC60601-1 General requirement for safety
• IEC60601-1-2 Requirements for EMC
• EN1060-4, NIBP clinical investigation
• AAMI / ANSI / IEC 80601-2-30, ANSI/AAMI/ISO 81060-2, NIBP requirements
• Batteries might leak chemicals if unused for a long time. Remove the
batteries if you are not going to use the device for an extended period
(i.e., 3 months or more).
• Properly dispose of the batteries according to your local environmental
regulations.
SYMBOL INFORMATION
DEALER’S INFORMATION
• Storage condition: -20°C to 70°C (-4°F to 158°F), between 10% to 95% relative
humidity.
• Always store or transport the meter in its original storage case.
• Avoid dropping or heavy impact.
• Avoid direct sunlight and high humidity.
1. To clean the meter exterior, wipe it with a cloth moistened with tap water or a
mild cleaning agent, then dry the device with a soft dry cloth. Do NOT flush
with water.
2. Do NOT use organic solvents to clean the meter.
3. Do NOT wash the pressure cuff.
4. Do NOT iron the pressure cuff.
To avoid the meter attracting dirt, dust or other contaminants, wash and dry your
hands thoroughly before use.
1. Connect AC adapter plug to DC adapter jack of the
meter.
1. When the meter is off, remove AC adapter power
plug from the electrical outlet.
2. Plug AC adapter power plug into an electrical outlet.
Press ON/OFF to start the measurement.
2. Disconnect AC adapter plug from DC adapter jack of
the monitor.
USING AC ADAPTER (only for TD-3124B)
CARING FOR YOUR METER
If you follow the recommended action but the problem persists, or error messages
other than the ones below appear, please call your local customer service. Do not
attempt to repair by yourself and never try to disassemble the monitor under any
circumstances.
SYSTEM TROUBLESHOOTING
Connect AC Adapter to the Meter
Cleaning
Meter Storage
Remove AC Adapter from the Meter
Error Messages
MESSAGE CAUSE WHAT TO DO
Ination or pressure error. Please contact local customer
service for help.
Ret cu tightly and correctly.
Relax and repeat the
measurement. If error still
remains, contact local
customer service for help.
Replace the batteries.
Review the instructions and
repeat the test. If the meter
still does not work, please
contact the local customer
service for help.
Blood pressure
measurement error.
Batteries are dead.
Problems with the meter.
POSSIBLE CAUSE WHAT TO DO
Batteries exhausted.
Batteries incorrectly installed or
absent.
Replace the batteries.
Check that the batteries are correctly
installed.
POSSIBLE CAUSE WHAT TO DO
Movement during measurement.
Measurement taken just after
exercise.
Repeat measurement.
Rest at least 30 minutes before
repeating measurement.
1. If no display appears after pressing :
2. If the heart rate is higher/lower than user’s average:
Troubleshooting
3. If the result is higher/lower than user’s average measurement:
POSSIBLE CAUSE WHAT TO DO
May not be in correct position while
measuring.
Blood pressure naturally varies from
time to time.
Adjust to the correct position to
measure.
Keep in mind for next measurement.
4. If the cuff inflates again while measuring:
POSSIBLE CAUSE WHAT TO DO
Cu is not fastened.
If user’s blood pressure is higher than the pressure the device has inated, the
device will automatically increase the pressure and start to inate again. Stay
relaxed and wait for the measurement.
Fasten the cu again.
Symbol Referent
Clinical studies show that adult diabetes is often accompanied by elevated blood
pressure. People with diabetes can reduce their heart risk by managing their
blood pressure along with diabetes treatment* .
Monitoring your routine blood pressure trend helps you to know your body
condition. Human blood pressure naturally increases after reaching middle age.
This symptom is a result of continuous ageing of the blood vessels. Further causes
include obesity, lack of exercise and cholesterol (LDL) adhering to the blood
vessels. Rising blood pressure accelerates hardening of the arteries, and the body
becomes more susceptible to apoplexy and coronary infarction.
DETAILED INFORMATION
Reference Values
SPECIFICATIONS
System performance
Blood pressure measurement performance
Four 1.5V AA alkaline batteries
130.5 mm (L) x 90 mm (W) x 55 mm (H),
210 g without batteries.
24-43 cm (9.4-16.9 inches)
with air tube 100 cm
Maximum 100 memory records (only for TD-3124B)
Automatic power o if system idle for 3 minutes
5
o
C to 40
o
C (41
o
F to 104
o
F), between 15% - 93% RH
-25
o
C to 70
o
C (-13
o
F to 158
o
F), between 10% - 95% RH
four (4)1.5V AA size alkaline batteries (for TD-3124A/B)
DC +6V / 1A (max) via Power Plug (only for TD-3124B)
Power source:
Size of monitor w/o cu:
Cu Size:
Memory:
Power saving:
System operating conditions:
Meter storage conditions:
Power Supply Input:
0 - 300 mmHg
mmHg
60 mmHg -255 mmHg
30 mmHg -195 mmHg
40 -199 beats / minute
280 mmHg
±3 mmHg or ±2% of reading
±4% of reading
40 - 199 beat per minute
Pressure range:
Measurement unit:
Systolic Measurement Range:
Diastolic Measurement Range:
Pulse Rate Measurement Range:
Maximum ination pressure:
Accuracy of Pressure:
Accuracy of Pulse rate:
Heart rate range:
Consult instructions for use
Manufacturer
Serial number
Caution, consult accompanying documents
Type BF Equipment
Collection for electrical and electronic equipment
Distributed by
ForaCare Global Corp.
1F, No. 127, Wugong 2nd Rd., Wugu District,
New Taipei City 24888, Taiwan
Tel: +886-2-66253345 Fax: +886-2-66259878
www.foracare.com
Manufacturer
TaiDoc Technology Corporation
B1-7F., No. 127, Wugong 2nd Rd.,
Wugu Dist., New Taipei City 248, Taiwan(R.O.C.)
www.taidoc.com
1. We warrant this product to be free of defects in workmanship and materials
within the said warranty period on the warranty certificate.
2. During the warranty period, if this product is found to be defective, you may bring it,
together with the purchase receipt and Warranty Certificate, on a carry-in basis to our
office during normal business hours for warranty service. We will then repair or replace
defective parts or exchanging the whole product as we may choose, at no charge to
the original owner. After such repair, replacement or exchange, the product will be
warranted for up to the remainder of the warranty period.
3.This warranty is valid only if the Warranty Certificate and Warranty Registration Card are
duly completed with date of purchase, serial number and dealer’s stamp, and if the
Warranty Registration Card is sent to our office not later than 14 days from the date of purchase.
4. This warranty is void if this product has been repaired or serviced by unauthorized person.
This warranty does not cover defects caused by misuse, abuse, accident, tampering, lack
of reasonable care, fire or any other acts beyond human control.
5. Except as stated in the above paragraphs, we disclaim all other warranties, implied or
expressed, including the warranties of merchantability or fitness for a particular purpose
with respect to the use of this product. We shall not be liable for any direct, consequential
or incidental damages arising out of the use or inability to use this product.
4
The recommended blood pressure range is as below:
*2: National Heart, Lung, and Blood Institute, Diseases and Conditions
*3: The Seventh Report of the Joint National Committee on Prevention, Detection,
Evaluation, and Treatment of High Blood Pressure. NIH Publication. 2003. No. 03-5233
*4: American Diabetes Association: The Diabetes-Heart Disease Link Surveying
Attitudes,
Classication Systolic Pressure (mmHg) Diastolic Pressure (mmHg)
Hypotension*
Normal*
Pre-hypertension*
Stage 1 Hypertension*
Stage 2 Hypertension*
Less than 90
Less than 120
120 – 139
140 – 159
160 or more
Less than 60
Less than 80
80 – 89
90 – 99
100 or more
2
3
3
3
3
SN
Other ForaCare Blood Pressure Monitor manuals
Popular Blood Pressure Monitor manuals by other brands

Omron
Omron M6 Comfort instruction manual

BIOS Diagnostics
BIOS Diagnostics BD280 instruction manual

Omron
Omron M5 instruction manual

Panasonic
Panasonic EW3037 - WRIST BP MONITOR operating instructions

Medinox
Medinox Econocare ECO-BP01 instruction manual

Soehnle
Soehnle SYSTO MONITOR 200 Instructions for use