●Output signal: RF(2.4GHz) + DMX512
●Input Voltage: 85-265VDC
●
●Sensitive tunable white and dimmable slider.
●
●When used as an RF controller it can be Paired with multiple receivers.
●
●
- FLWP4T
RF / DMX Control - 4 Zone Tuneable Touch Wall Panel
.
User Guide
Technical Parameters
Remote distance up to 30m within Free Range. Please allow for 12m within
areas restricted by obstacles.
Pairing Guide
Pairing your Wall Panel with each 2.4G RF receiver
● Using the "Match Key"
1. Match: Switch off receiver power, then switch on power again,
short press zone key 3 times on the wall panel quickly within 5s after receiver power on,
the link has been completed once the connected LED lights flash 3 times.
Repeat this process to link further receivers to the wall panel.
2. To Delete a match:
Switch off power to the receiver, then switch on power again,
short press the zone key you are deleting 5 times on the remote within 5s after power on,
the unlink has been completed once the connected LED lights flash 5 times.
.
Key Functions
Dimensions
Features
●
●
●
Light Type: Tuneable White
Size: 86x86x35 mm
62.00 mm
4 Zone Touch panel compatible with both DMX512 (FLDC4Y-DMX) and RF (FLDC4Y) receivers.
Set and save several Scene modes
Features
● At Power Up
Match the controller with our receiver (Without using the Match Key)
1.
Match
:
Switch off receiver power, then switch on power again,
short press zone key 3 times on the remote quickly within 5s after receiver power on,
the link has been completed once the connected LED lights flash 3 times.
2. To Delete a match:
Switch off power to the receiver, then switch on power again,
short press the zone key you are deleting 5 times on the remote within 5s after power on,
the unlink has been completed once the connected LED lights flash 5 times.
.
Turn On/O
Lighting in all
Zones
Short press will recall
previously saved scenes. To
save a new scene, hold scene
button for 2s.
Tuneable White / Brightness
Slider
Zone Selection - Short press to
select and turn on lighting in
that Zone. Long press 2s to
turn of the lighting in this
Zone.
Short press multiple Zone keys
quickly to control Zones
simultaneously.
RF Receiver - FLDC4Y
DMX Receiver - FLDC4Y-DMX
Installation Diagram
Typical base as below:
UninstallTouch panelBaseplateBase
Ɣ
The product shall be installed and serviced by a qualified person.
Ɣ
The product is non-waterproof.
Ɣ
Good heat dissipation will prolong the working life of the controller, Please ensure good ventilation.
Ɣ
Please check if the output voltage of any power supplies used comply with the working voltage
of the product.
Ɣ
Ensure all wire connections and polarities are correct
Ɣ
If a fault occurs please return the product to your supplier. Do not attempt to fix this product by yourself.
Safety Information
Wiring Diagram for DMX 512
L NGNDD+ D-
DMX OUTPUT
I NPUT
110-265VAC
RoHS
Uin=85-265VAC
Iin=Max 0.1A
Out=DMX512 Signal
Uin=12-24VDC
Iin=20.5A
Uout=4×(12-24)VDC
Iout=4×5A
Pout=4×(60-120)W
Temp Range:
-30~+55
FLDC4Y-DMX DMX512 & RDM Decoder
DMX IN/OUT
D+ D- D+ D-
+
+
NW
WW
NW
WW
Tunable White LED strip x 2
Uin=12-24VDC
Iin=20.5A
Uout=4×(12-24)VDC
Iout=4×5A
Pout=4×(60-120)W
Temp Range:
-30~+55
FLDC4Y-DMX DMX512 & RDM Decoder
DMX IN/OUT
D+ D- D+ D-
+
+
DMXsignal
Power Supply
12-24VDC
Constant Voltage
N
AC110-230V
NW
WW
NW
WW
Dual color LED strip x 2
DMXsignal
Each zone two channel:
zone 1 is channel 1 ~ 2,
zone 2 is channel 3 ~ 4,
zone 3 is channel 5 ~ 6,
zone 4 is channel 7 ~ 8,
channel 1,3,5,7 is WW,
channel 2,4,6,8 is CW.
DMX channel address assignment
L
N
AC85-265V
Powerinput

Other fossLED Controllers manuals

fossLED FLWP4S User manual

fossLED

fossLED FLWP4S User manual

fossLED FLWP1S User manual

fossLED

fossLED FLWP1S User manual

Popular Controllers manuals by other brands

Alpha Technologies Cordex CXC Series Removal Procedure

Alpha Technologies

Alpha Technologies Cordex CXC Series Removal Procedure

rotork Modbus IQ Pro Technical manual

rotork

rotork Modbus IQ Pro Technical manual

Siemens GDB 1 Series Mounting instructions

Siemens

Siemens GDB 1 Series Mounting instructions

Extron electronics VNM Enterprise Setup guide

Extron electronics

Extron electronics VNM Enterprise Setup guide

Danfoss AMV 150 instructions

Danfoss

Danfoss AMV 150 instructions

Siemens RAJA+ 3TE7111-2SC18-1A Series Installation, operation & maintenance instructions

Siemens

Siemens RAJA+ 3TE7111-2SC18-1A Series Installation, operation & maintenance instructions

THOR THPWM-30 instruction manual

THOR

THOR THPWM-30 instruction manual

Novus N321R operating manual

Novus

Novus N321R operating manual

Piusi ACCESS 85 Installation and use manual

Piusi

Piusi ACCESS 85 Installation and use manual

Vexve AM40 instruction manual

Vexve

Vexve AM40 instruction manual

AOR AR-21 operating instructions

AOR

AOR AR-21 operating instructions

GET LC-GPA Guide

GET

GET LC-GPA Guide

Eltako FSB71-2x-230V manual

Eltako

Eltako FSB71-2x-230V manual

Proton ECOMATIC PRO Operation manual

Proton

Proton ECOMATIC PRO Operation manual

Emko Elektronik A.S.. ESM-4435 instruction manual

Emko Elektronik A.S..

Emko Elektronik A.S.. ESM-4435 instruction manual

Banner Sure Cross DXM100-Bx instruction manual

Banner

Banner Sure Cross DXM100-Bx instruction manual

Acuity Brands gotham Renaissance Lighting Rhapsody instruction manual

Acuity Brands

Acuity Brands gotham Renaissance Lighting Rhapsody instruction manual

Pioneer DDJ-ERGO Setting file import guide

Pioneer

Pioneer DDJ-ERGO Setting file import guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.