INSTALLATION INSTRUCTIONS
FRANKE
DESIGNER CERAMIC COOKTOP 60CM
page 3 of 3
Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference
• Materials which are often used to make worktops expand on contact with water. To protect the cut out edge, apply a coat of
varnish or special sealant. Particular care must be given to applying the adhesive joint supplied with the hob to prevent any
leakage into the supporting furniture. This gasket guaranties a correct seal when used in conjunction with smooth work top
surfaces.
• The safety gap between the hob and the cooker hood placed above must respect the indications of the hood manufacturer.
In case of absence of instructions respect a distance minimum of 760 mm.
• The connection cord should not be subjected to mechanical constraint, for example a drawer.
•WARNING: Use only hob guards designed by the manufacturer of the cooking appliance or indicated by the manufacturer
of the appliance in the instructions for use as suitable or hob guards incorporated in the appliance. The use of inappropriate
guards can cause accidents.
ELECTRICAL CONNECTION
• The installation of this appliance and the connection to the electrical network should be entrusted only to an electrician
perfectly to the fact of the normative regulations and which respects them scrupulously.
• Protection against the parts under tension must be ensured after the building-in.
• The data of connection necessary are on the stickers placedon the hob casing near the connection box.
• The connection to the main must be made using an earthed plug or via an omnipolar circuit breaking device with a contact
opening of at least 3 mm.
•The electrical circuit must be separated from the network by adapted devices, for example: circuit breakers, fuses or contac-
tors.
•If the appliance is not fitted with an accessible plug, disconnecting means must be incorporated in the fixed installation, in
accordance with the installation regulations.
• The inlet hose must be positioned so that it does not touch any of the hot parts of the hob.
CAUTION!
This appliance must only to be connected to a network 230 V~ 50/60 Hz.
Always connect always the earth wire.
Respect the connection diagram.
The connection box is located underneath at the back of the hob casing. To open the cover use a medium screwdriver. Place it
in the slits and open the cover.
We cannot be held responsible for any incident resulting from incorrect connection or which could arise from the use of an ap-
pliance which has not been earthed or has been equipped with a faulty earth connection.
CONNECTION OF THE HUB FOR:
Mains Connection Supply Cord Supply Cord Circuit Braker
230V~ 50/60Hz 1 Phase + N 3 x 2,5mm2H 05 VV - F
H05 RR - F
25 A *
400V~ 50/60 Hz 2 Phases + N 4 x 1.5 mm2H 05 VV - F
H 05 RR - F
16 A *
* calculated with the simultaneous factor following the standard EN 60 335-2-6
Connection of the hob
For the various kinds of connection, use the brass bridges which are in the box next the terminal
Monophase 230V~1P+N
Put the 1st bridge between terminal 1 and 2
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L to one of the terminals 1 or 2.
Biphase 400V~2P+N
Attach the earth to the terminate “earth”, the neutral N to terminal 4, the Phase L1 to the terminals 1 and the Phase L2 to the
terminal 2.