REPLACEMENT AND INSTALL GUIDE
SUBDRIVE UTILITY FAN
2
FAN TEST
1. The fan can be unplugged from the drive and tested with a
9 V battery to show functionality.
• Connect the red (+) lead from the battery to the red fan lead,
and the black (-) lead from the battery to the black fan lead.
• Connect the battery clip to the 9 V battery. The fan should
spin freely and quietly.
2. Test that the fan power supply works properly.
• Cycle power to the drive.
• Verify that the fan runs for 3–5 seconds during
the power-up initialization.
If the fan does not perform as stated above, note the error and consult
your local Franklin Electric representative or call the Franklin Electric
Technical Service Hotline at 1-800-348-2420.
Serious or fatal electrical shock may result from contact with the internal electrical components. DO NOT, under any circumstances,
ATTEMPT TO CHANGE THE FAN until the power has been removed from the drive, capacitors are discharged, and 10 minutes have passed for
internal voltages to discharge! Before replacing the fan, make sure the fan is working properly by performing the simple test below:
s
!
WARNING