Fresenius 2008®K Calibration Procedures
P/N 507296 Rev D
CALIBRATION PROCEDURES
TABLE OF CONTENTS
1.0 INTRODUCTION ..................................................................................................... 1
1.1 TEST EQUIPMENT NEEDED.......................................................................................................2
1.2 OPERATING MODES...................................................................................................................3
1.3 FRONT PANEL CONTROLS........................................................................................................6
1.4 MEASURING FLUID VOLUMES..................................................................................................8
1.5 CALIBRATE IF REPLACED.........................................................................................................9
2.0 SERVICE MODE CALIBRATIONS ......................................................................... 10
2.1 TOUCH SCREEN CALIBRATION..............................................................................................10
2.2 HYDRAULIC CALIBRATION PROCEDURES ...........................................................................11
2.2.1 DEAERATION AND LOADING PRESSURE CALIBRATION............................................................12
2.2.2 FLOW PRESSURE CALIBRATION..................................................................................................15
2.2.3 BALANCE CHAMBER VOLUME CALIBRATION..............................................................................16
2.2.4 ACID (CONCENTRATE) PUMP VOLUME CALIBRATION...............................................................18
2.2.5 BICARBONATE PUMP VOLUME CALIBRATION............................................................................20
2.2.6 UF PUMP VOLUME CALIBRATION.................................................................................................22
2.3 SENSOR CALIBRATION PROCEDURES .................................................................................25
2.3.1 ARTERIAL PRESSURE CALIBRATION...........................................................................................26
2.3.2 VENOUS PRESSURE CALIBRATION .............................................................................................32
2.3.3 DIALYSATE PRESSURE CALIBRATION.........................................................................................35
2.3.4 TEMPERATURE SENSOR CALIBRATION...................................................................................... 37
2.3.5 POST TEMPERATURE SENSOR CALIBRATION............................................................................39
2.3.6 TEMPERATURE CONTROL CALIBRATION....................................................................................41
2.3.6.1 TEMPERATURE CONTROL CALIBRATION (METHOD 1)....................................................42
2.3.6.2 TEMPERATURE CONTROL CALIBRATION (METHOD 2)....................................................45
2.3.6.3 TEMPERATURE CONTROL CALIBRATION (METHOD 3)....................................................49
2.3.6.4 TEMPERATURE CONTROL CALIBRATION (METHOD 4).................................................... 52
2.3.7 BLOOD LEAK CALIBRATION ..........................................................................................................55
2.3.8 CONDUCTIVITY CELLS CALIBRATION..........................................................................................57
2.3.8.1 CONDUCTIVITY CELLS CALIBRATION (v2.16 or less)........................................................57
2.3.8.2 CONDUCTIVITY CELLS CALIBRATION (v2.25 or greater)...................................................59
2.4 MONITOR CALIBRATION PROCEDURES...............................................................................62
2.4.1 SET CLOCK......................................................................................................................................63
2.4.2 VOLTAGE DETECTION CALIBRATION...........................................................................................64
2.4.3 ARTERIAL PUMP RATE................................................................................................................... 67
2.4.4 VENOUS PUMP RATE.....................................................................................................................68
3.0 CALIBRATION PROCEDURES NOT PERFORMED IN SERVICE MODE ................. 69
3.1 INLET WATER PRESSURE REGULATOR CALIBRATION......................................................69
3.2 LEVEL DETECTOR CALIBRATION ..........................................................................................71
3.3 BLOOD PUMP CALIBRATION ..................................................................................................73