• For maximum efficiency, use shortest, straightest duct run possible. 
Unit operates most efficiently with up to 100 equivalent feet of duct. 
(Refer to Calculating Duct Length Table in Product Installation Guide.) 
• Flexible ducting is not recommended due to severely restricted 
airflow; if blower outlet and floor or wall duct location do NOT align, 
flexible METAL ducting can be used to adapt to offset.
• Thermal breaks such as short section of nonmetallic duct, should 
be used in areas of extreme cold. Cold weather installations should 
have additional backdraft damper installed. 
Note: For planning purposes only. Refer to Product Installation Guide 
on the web at frigidaire.com for detailed instructions.
Optional Accessories
• Alternate Duct Transition Kit – (PN # 5304488297).
Built-In Cooktop Ductwork Preparation
• Ventilation unit comes detached from cooktop. To ensure proper 
installation, refer to 36" Electric Downdraft Cooktop Specifications 
page for planning information, and installation guide on web for 
complete installation details including countertop and cabinet 
requirements.
• Ducting Options – On floor, through floor or through wall. 
• Ventilation Unit Discharge Options – Rear or down. 
• Down discharge can also be adapted for alternate ductwork 
installation providing left or right exhaust, by ordering Alternate 
Duct Transition Kit (PN # 5304488297).
• Consider ductwork location and desired installation before cutting 
exhaust outlet hole in cabinet. For proper installation, cooktop 
exhaust duct MUST be located between wall studs or floor joists. 
• Vent exhaust air outside only and NOT into any concealed space.
• Exhaust Duct Required – Galvanized or aluminum duct in 6" round 
or 3-1/4" x 10" rectangular, or combination of both. PVC should 
be used if installing under concrete slab.
• Local building code must be followed in specifying approved type 
and schedule of ALL duct used; always use appropriate roof or 
wall cap with damper.
USA 
•
 10200 David Taylor Drive 
•
 Charlotte, NC 28262 
•
 1-800-FRIGIDAIRE •frigidaire.com
CANADA 
•
 5855 Terry Fox Way 
•
 Mississauga, ON L5V 3E4 
•
 1-800-265-8352 
•
 frigidaire.ca
RC36DE60P 07/13 © 2013 Electrolux Home Products, Inc. 
Built-In Downdraft Cooktop
RC36DE60PB 36" Electric
36" Electric Downdraft Cooktop – 
Ductwork Preparation
Ventilation unit comes detached from cooktop. 
To ensure proper installation, refer to 36" Electric Downdraft 
Cooktop Specifications page for planning information, and 
installation guide on web for complete installation details 
including countertop and cabinet requirements.
Ducting Options
On floor, through floor or through wall.
36" Electric Downdraft Cooktop – 
Ductwork Preparation
Electrical 
Installation Note: 
Locate junction 
box under cabinet 
within shaded 
area shown and 
run 120/240 or 
120/208 Volt, AC 
wire from main 
circuit panel. 
C
L
4
 
1
/2"5
 
1/2"6"
Countertop 
surface
Cabinet 
side wall
Cabinet 
side wall
Electrical Supply Location
Bottom 
Exhaust Outlet
Cutout
center
3
 
27/32"
1
 
3/16"
Cutout
center 8
 
27/32"
1
 
3/16"
Rear Wall 
Exhaust Outlet
Alternate 
Side Exhaust
Outlets
Cutout
center
22
 
3/4"
3
 
3/4"
6"
Alternate Duct Transition Kit 
PN #5304488297
Available for use with 
left or right exhaust 
ductwork. 
Exhaust Outlet Locations –
Cut exhaust outlet hole in wall or floor based on 
desired installation. Exhaust duct MUST be located 
between wall studs or floor joists.