FrSky RX8R PRO User manual

FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : [email protected]
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
What’s New!
•
Higher precision: the deviation of PWM is reduced to 0.5μs
•
Lower latency: compared with X8R under HS mode, PWM output delay of RX8R PRO reduces at most 9ms.
•
Strong ani-interference: it improves the anti-interference.
Introduction manual for FrSky RX8R PRO
Specifications
•
Dimension: 46.3*26.6*14.2mm (L×W×H)
•
Weight: 14.8g
•
Numbers of Channle: 16CH (1-8CH PWM or 9-16CH PWM from conventional channel outputs, 1-16CH from SBUS port)
•
With RSSI Output on Board: Analog 0~3.3V
•
Operating Voltage range: DC 3.5~10V
•
Operating Current: 100mA@5V
•
Operating Range: full range (> 1.5km)
•
Firmware Upgradeable
•
Servo frame rate:
9ms (HS-High Speed Mode)
18ms (FS-Normal Speed Mode)
•
Compatibility: FrSky transmitters/transmitter modules in D8/D16 mode
Instruction Manual for FrSky RX8R PRO
Thank you for purchasing FrSky RX8R PRO 8/16CH full duplex telemetry receiver. It has three characteristics: high precision, low
latency and strong anti-interference. In order to fully enjoy the benefits of this system, please read the instruction manual carefully and
set up the device as described below.
Introduction
S
mart Port
For Taranis X9D/X9D Plus and Taranis QX7/X7S, go to the MENU-MODEL SETUP-PAGE 2, choose Internal/External RF mode, then
select Bind and choose telemetry or not.
For Horus X12S/X10/X10S, turn on the transmitter, go to the RF SYSTEM, choose Internal/External RF mode, then select Bind and
choose telemetry or not.
H
ow to enable/disable telemetry on receiver
After binding procedure is completed, repower the receiver and check if it is really under control by linked transmitter.
Binding is the process of uniquely associating a particular receiver to a transmitter/transmitter mudole. A transmitter/transmitter module
could be bound to multiple receivers (no to be used simultaneously). A receiver could only be bound to one transmitter/ transmitter module.
Follow the steps below to complete the binding procedure.
1. Put the transmitter/transmitter module into binding mode
1.1 For Taranis X9D/X9D Plus/X9E and Taranis Q X7/X7S, turn on the transmitter, go to the MENU—MODEL SETUP—PAGE 2,
choose Internal or External RF, and select BIND.
1.2 For Horus X12S/X10S/X10, turn on the transmitter, go to RF system, choose Internal or External RF, and select BIND under STATE.
1.3 For transmitter module (XJT as en example), choose D16/D8 mode first, and turn on External RF on the transmitter while holding
the F/S button on the module, release the button and the RED LED on XJT module will flash.
2. Connect the battery to the receiver while holding the F/S button on the receiver. The RED LED on the receiver will flash, indicating
the binding process is completed.
3. Turn off both the transmitter and the receiver.
4. Turn on the transmitter and connect the battery. The GREEN LED on the receiver indicates the receiver is receiving commands from
the transmitter. The receiver/transmitter module binding will not have to be repeated, unless one of the two is replaced.
B
inding procedure
R
ange check
A pre-flight range check should be done before each flying session. Reflections from nearby metal fences, concrete buildings or trees may
cause loss of signal during range check and flight. Under Range Check mode, RF power will decrease to 1/30 of normal state and range
to 1/10.
Follow the steps as described below.
1. Place the model at least 60cm (about two feet) above non-metal contaminated ground (e.g on a wooden bench). Make sure the
receiver’s antennas should be in vertical position.
2. For Taranis X9D/X9D Plus/X9E and Taranis Q X7/X7S, go to MODEL SETUP (Page 2/13)— External RF/Internal RF, choose
corresponding module and then Rng.
For Horus X12S/X10S/X10, go to MDL— RF SYSTEM, choose ON under External RF and RANGE under state.
For more detailed information, please refer to the related manuals.
Redundancy Function
RX8R PRO supports the redundancy function. It
receives the SBUS signal from the slave receiver.
The slave receiver must have SBUS output (for
example, Frsky XM+, XM, R-XSR, L9R, etc.)
PRO
Overview
PRO
All data measured by S.Port supported products could be transmitted back to the transmitter.
Make sure telemetry is disabled on the slave receiver when the
slave receiver is Frsky X series receiver. XM+ is recommended as the slave
receiver.
Do not connect the SBUS IN on a RX8R PRO to the SBUS OUT on itself.
Two RX8R PRO could not be the redundancy receiver to each other.
If you do so, failsafe will not work under the two conditions above.
The distance bewteen the antenna of RX8R PRO and CDI ignitor must be no less than 20cm if CDI ignitor is used.
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : [email protected]
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
FrSky is continuously adding features and improvements to our products. To get the most from your product, please check
the download section of the FrSky website www.frsky-rc.com for the latest update firmware and manuals
Failsafe setting via transmitter for channel output position is just for D16 RF mode. Besides, Failsafe setting via transmitter
has higher priority to that via receiver.
•
For Horus X12S/X10S/X10, turn on the transmitter, go to MDL—FAILSAFE.
2. Set on the receiver
•
Short press F/S button while moving channel positions to a preset value after binding.
There are 3 failsafe modes: No pulse, Hold, Custom.
•
No pulse: On loss of signal, the receiver produces no pulses on any channle. To apply the mode, select it in the menu and wait 9
seconds for the failsafe to take effect.
•
Hold: The model will maintain the last position after loss of signal. To apply the mode, select it in the menu and wait 9 seconds for
the failsafe to take effect.
Failsafe is a useful feature which is for a preset channel output position whenever control signal is lost for a period. Failsafe for receiver
supporting D16 RF mode can be set via transmitter’s interface, which supports no pulse, hold and custom for each channel.
Follow the steps below to set failsafe
1. Set on the transmitter
•
For Taranis X9D/X9D Plus and Taranis Q X7S/X7, turn on the transmitter, go to MODEL SETUP—Internal RF/External RF—Failsafe.
F
ailsafe
Introduction manual for FrSky RX8R PRO
How to switch operating mode
Normal mode of RX8R PRO is D16.
D8 mode only operates when the signal pins of CH7&CH8 are jumped before bind.
How to switch servo frame rate
Normal servo frame rate is 18ms(FS-Normal Speed Mode).
High Speed Mode (9ms) only operates when the signal pins of CH5&CH6 are jumped before bind.
FrSky Electronic Co., Ltd www.frsky-rc.com Contact us : [email protected]
Add:F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
Introduction manual for FrSky RX8R PRO
•
Custom: The customized position of each individual channel. The model will move to the pre-set position after loss of signal. Move
the cursor to set and press ENTER, you will see FAILSAFE SETTING screen below. Move the cursor to the channel you want to set
failsafe on, and press ENTER. When moving the corresponding sticks or switches, you will see the channel bar moving. Move the channel
bar to the place you want for failsafe and long press ENTER to finish the setting. Wait 9 seconds before failsafe taking effect.
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
-Consult the dealer or an experienced radio/TV technician for help.

Other manuals for RX8R PRO

1

Other FrSky Receiver manuals

FrSky ARCHER PLUS SR8 User manual

FrSky

FrSky ARCHER PLUS SR8 User manual

FrSky ARCHER PLUS R6Mini User manual

FrSky

FrSky ARCHER PLUS R6Mini User manual

FrSky ARCHER R8 PRO User manual

FrSky

FrSky ARCHER R8 PRO User manual

FrSky ARCHER PLUS R8 User manual

FrSky

FrSky ARCHER PLUS R8 User manual

FrSky ACCESS RX4R User manual

FrSky

FrSky ACCESS RX4R User manual

FrSky D8R-XP User manual

FrSky

FrSky D8R-XP User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky TFR8 User manual

FrSky

FrSky TFR8 User manual

FrSky ACCST Taranis X9E User manual

FrSky

FrSky ACCST Taranis X9E User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky D6FR User manual

FrSky

FrSky D6FR User manual

FrSky Delta 8 User manual

FrSky

FrSky Delta 8 User manual

FrSky TW R6 User manual

FrSky

FrSky TW R6 User manual

FrSky RX6R User manual

FrSky

FrSky RX6R User manual

FrSky TD R12 User manual

FrSky

FrSky TD R12 User manual

FrSky R9MM-FC-OTA User manual

FrSky

FrSky R9MM-FC-OTA User manual

FrSky L9R User manual

FrSky

FrSky L9R User manual

FrSky ACCST G-RX6 User manual

FrSky

FrSky ACCST G-RX6 User manual

FrSky TD R10 User manual

FrSky

FrSky TD R10 User manual

FrSky ARCHER SR8 PRO User manual

FrSky

FrSky ARCHER SR8 PRO User manual

FrSky Taranis X9D Plus User manual

FrSky

FrSky Taranis X9D Plus User manual

FrSky ARCHER GR6 User manual

FrSky

FrSky ARCHER GR6 User manual

FrSky 2.4GHz ACCESS R-XSR User manual

FrSky

FrSky 2.4GHz ACCESS R-XSR User manual

FrSky Dragon Fire Series User manual

FrSky

FrSky Dragon Fire Series User manual

Popular Receiver manuals by other brands

TechniSat VIACCESS DigiBox VIACCESS instruction manual

TechniSat

TechniSat VIACCESS DigiBox VIACCESS instruction manual

Rotel RX-975 Technical manual

Rotel

Rotel RX-975 Technical manual

Kathrein UFD 430 Mode d'emploi

Kathrein

Kathrein UFD 430 Mode d'emploi

Aiwa FR-AQ505 Service manual

Aiwa

Aiwa FR-AQ505 Service manual

Yamaha RX-A2020 quick guide

Yamaha

Yamaha RX-A2020 quick guide

Monacor IMG Stage line ATS-162R instructions

Monacor

Monacor IMG Stage line ATS-162R instructions

Green Dot N8102T user manual

Green Dot

Green Dot N8102T user manual

Jobsite IR-WMR Installation and user guide

Jobsite

Jobsite IR-WMR Installation and user guide

Extron electronics Twisted Pair Transmitter TP T 15HD A Specification sheet

Extron electronics

Extron electronics Twisted Pair Transmitter TP T 15HD A Specification sheet

Eurotek EK-MFR/1 Users handbooks

Eurotek

Eurotek EK-MFR/1 Users handbooks

Onkyo HT-R570 Service manual

Onkyo

Onkyo HT-R570 Service manual

Nice tt2d instruction manual

Nice

Nice tt2d instruction manual

Kenwood KMM-BT332 instruction manual

Kenwood

Kenwood KMM-BT332 instruction manual

Onkyo CR-245 Service manual

Onkyo

Onkyo CR-245 Service manual

Daewoo DCR-9130 SERIES Service manual

Daewoo

Daewoo DCR-9130 SERIES Service manual

Fisher 800-B Operating instructions and warranty

Fisher

Fisher 800-B Operating instructions and warranty

Lectrosonics UR190 Operating instructions and troubleshooting guide

Lectrosonics

Lectrosonics UR190 Operating instructions and troubleshooting guide

Aiwa FR-A250 Service manual

Aiwa

Aiwa FR-A250 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.