manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FrSky
  6. •
  7. Receiver
  8. •
  9. FrSky Archer R10 Pro User manual

FrSky Archer R10 Pro User manual

Instruction Manual for FrSky ARCHER GR8 Receiver
Version
1.0
LED state
Green LED
On
Flash
On
On
On
Off
Red LED
On
Flash
On
Off
Off
On
Status
Register
Register successfully
Bind
Bind successfully
Working normally
Failsafe
Version
1.1
Instruction Manual for FrSky ARCHER R10 PRO Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
01140166
Introduction
The Archer R10 Pro has 10 high-precision PWM channel outputs and features excellent Anti-interference performance when it comes
to spark-ignition on internal combustion models. It supports full-range signal strength with dual detachable antennas that assure
optimal antenna reception and maximum range. In addition to all this, the R10 PRO can also be used as a redundancy receiver along
with any other FrSky ACCESS capable receiver equipped with a SBUS port. This 10-channel receivers’ noticeable features are its
Anti-vibration performance and dual-battery ports for redundancy.
All of the Archer receivers are hyper-matched with the ACCESS protocol. They not only feature wireless firmware upgrades, increased
range, and telemetry performance, the R10 PRO now supports more functions like configurable telemetry power, S.Port/F.Port
switching and FLR output. Additional valuable features are under development to unlock the true potential of the ACCESS protocol.
Overview
SBUS OUT
SBUS IN
CH1
CH2
CH3
CH4
CH5
CH6
CH7
CH8
CH9
CH10
VBATVBAT
INPUT:DC 3.5V~10V
LED
2
R10 Pro
10/24CH Telemetry
BUTTON
Warning: Do not plug the additional
power supply in other port
(
Channel,
S.Port, SBUS, etc.
)
while using dual
battery to power the receiver.
Specifications
●
Dimension: 48.5*33*17mm (L*W*H)
●
Weight: 21g
●
16/24 Configurable SBUS Channels
●
10 High-precision PWM Channels
●
Operating Voltage Range: 3.5-10V
●
Operating Current: 80mA@5V
●
Battery ports: XT30
● Control Range: Full range* with telemetry
(*Full Range: >2km, range may vary based
on local conditions.)
● Voltage Measurement Range via AIN2
(External device): 0-36V
(Battery Voltage Division Ratio: 1:10)
● Compatibility: All FrSky ACCESS transmitters
Features
● ACCESS protocol with Over The Air (OTA)
● Supports signal redundancy (SBUS In)
● Supports power redundancy (Dual battery ports)
* it will automatically be powered by the one with highervoltage.
● S.Port / F.Port
● Anti-interference in spark-ignition
● Anti-Vibration
● External battery / device voltage detection
● VFR (Valid Frame Rate) telemetry
Registration & Automatic binding (Smart Match )
With the FrSky ACCESS protocol, the transmitter/transmitter module can bind receiver without using the "REG" button.
Follow the step below to finish the Registration & binding procedure:
1. Put the transmitter/transmitter module into [Reg] status.
1.1 For Taranis X-Lite Pro as an example, turn on the transmitter, go to the MENU-MODEL SETUP-PAGE 2,choose Internal or External
RF, and select [Reg].
2. Connect the battery to the receiver while holding the button on the receiver. The RED LED and GREEN LED on the receiver will be
on, indicating into the [Reg] status. Select [ENTER] on the transmitter, The RED LED and GREEN LED on the receiver will flash, and
the transmitter displays [Registration ok].
3. Turn off the receiver.
4. Move the cursor to select the receiver 1 [Bind].
5.
Connect the battery to the receiver, the GREEN LED will flash, indicating into the [Bind] status. Select the RX, the GREEN will keep
lit, and the transmitter displays [Bind successful].
6. The transmitter exit [Bind], GREEN LED will keep lit, RED LED will be off, indicating Working normally.
TM
FrSky is continuously adding features and improvements to our products. To get the most from your product, please check
the download section of the FrSky website www.frsky-rc.com for the latest update firmware and manuals
Version
1.1
Instruction Manual for FrSky ARCHER R10 PRO Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
01140166
FCC STATEMENT
1. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interference received, including interference that may cause undesired operation.
2. Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate
the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
Note: The SBUS output is 7ms, no matter HS/FS mode.
Warning: HS mode is only applied for digital servos. Other servos should select FS mode, otherwise servos will get hot
and may burn out.
How to Switch FS (20ms) mode/HS (7ms) mode
a) The factory default setting is FS mode.
b) To go to the receiver [Options], select the 7 ms PWM or not.
Warning: [Options ] setting in flight will cause the failsafe.
About OTA function
-- For Taranis X-Lite Pro as an example, go to the SD CARD 2/7, and select the FW, press the enter button, select [Flash receiver
OTA], power on the receiver, select the RX, go to the [ENTER], complete the flash process, the transmitter will display [Flash
successful]. Re-power the receiver and wait for 3 seconds, the Green LED starts flashing indicates the receiver works properly at the
momemnt.
Note: Please do not do the binding operation in the near range while the firmware upgrading in progress.
Note: Update the firmware after the receiver gets bound.
Range Check
A pre-flight range check should be done before each flying session. Reflections from nearby metal fences, concrete buildings or trees
can cause loss of signal both during range check and during the flight. Under Range Check Mode, the RF power would be decreased
and Range distance to 1/30 --1/10 that of Normal Mode.
* The signal is completely lost is recommended as the node to complete the range test.
1. Place the model at least 60cm (two feet) above non-metal contaminated ground (e.g. on a wooden bench). The receiver antenna
should be in vertical position.
2. For Taranis X-Lite Pro as an example, turn on the transmitter and power on the receiver, go to: SETUP 2/13 /Internal RF/ Module
[Rng].
3. For transmitter RF module, please refer to its manual.
Much more operation and instruction please refer to radio manual.
Failsafe
Failsafe is a useful feature which is for a preset channel output position whenever control signal is lost for a period.
Follow the steps to set Failsafe for channels necessary:
Failsafe for receiver supporting ACCESS can be set via radio interface, which support no pulse, hold and custom three modes for
each channel.
1. For Taranis X-Lite Pro as an example, turn on the transmitter, go to: MODEL SETUP/Internal RF/Failsafe.
2. Failsafe can be set on receiver via short pressing F/S button while moving a certain channel position to a preset value after binding.

Other FrSky Receiver manuals

FrSky R9MM-FC-OTA User manual

FrSky

FrSky R9MM-FC-OTA User manual

FrSky ARCHER M+ User manual

FrSky

FrSky ARCHER M+ User manual

FrSky TWIN Series User manual

FrSky

FrSky TWIN Series User manual

FrSky XJT User manual

FrSky

FrSky XJT User manual

FrSky TWIN Series User manual

FrSky

FrSky TWIN Series User manual

FrSky RX8R PRO User manual

FrSky

FrSky RX8R PRO User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky ARCHER PLUS SR10+ User manual

FrSky

FrSky ARCHER PLUS SR10+ User manual

FrSky DFT User manual

FrSky

FrSky DFT User manual

FrSky ACCESS RX4R User manual

FrSky

FrSky ACCESS RX4R User manual

FrSky HORUS X10 User manual

FrSky

FrSky HORUS X10 User manual

FrSky TANDEM X20 Series User manual

FrSky

FrSky TANDEM X20 Series User manual

FrSky RX6R User manual

FrSky

FrSky RX6R User manual

FrSky ARCHER R10 PRO User manual

FrSky

FrSky ARCHER R10 PRO User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky Delta 8 User manual

FrSky

FrSky Delta 8 User manual

FrSky Horus X12S-ISRM User manual

FrSky

FrSky Horus X12S-ISRM User manual

FrSky ACCESS G-RX8 User manual

FrSky

FrSky ACCESS G-RX8 User manual

FrSky ARCHER R8 PRO User manual

FrSky

FrSky ARCHER R8 PRO User manual

FrSky RX8R PRO User manual

FrSky

FrSky RX8R PRO User manual

FrSky TD R18 User manual

FrSky

FrSky TD R18 User manual

FrSky TW R6 User manual

FrSky

FrSky TW R6 User manual

FrSky X4R-SB User manual

FrSky

FrSky X4R-SB User manual

FrSky RX6R User manual

FrSky

FrSky RX6R User manual

Popular Receiver manuals by other brands

LG LH-W7501TA Service manual

LG

LG LH-W7501TA Service manual

Kathrein Euroline UFE 336S operating manual

Kathrein

Kathrein Euroline UFE 336S operating manual

Onkyo HT-R570 Service manual

Onkyo

Onkyo HT-R570 Service manual

Pioneer DMH-WT86NEX Operation manual

Pioneer

Pioneer DMH-WT86NEX Operation manual

LG SH93TA-S Service manual

LG

LG SH93TA-S Service manual

Dual DXRM58BT quick start guide

Dual

Dual DXRM58BT quick start guide

Pyle PT592A user manual

Pyle

Pyle PT592A user manual

DStv HD Decoder quick guide

DStv

DStv HD Decoder quick guide

Vishay TSOP61 Series manual

Vishay

Vishay TSOP61 Series manual

Codan MT-4E user guide

Codan

Codan MT-4E user guide

Marantz SR-66 Service manual

Marantz

Marantz SR-66 Service manual

Sony STR-DA3000ES Easy setup guide

Sony

Sony STR-DA3000ES Easy setup guide

Sony STR-DA3400ES Specifications

Sony

Sony STR-DA3400ES Specifications

Sherwood Newcastle R-965 brochure

Sherwood

Sherwood Newcastle R-965 brochure

Sennheiser EK 2020-D datasheet

Sennheiser

Sennheiser EK 2020-D datasheet

Pyle PT696BT user manual

Pyle

Pyle PT696BT user manual

Clarion FX109 user manual

Clarion

Clarion FX109 user manual

Harman Kardon AVR 1600 Settings guide

Harman Kardon

Harman Kardon AVR 1600 Settings guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.