manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. FrSky
  6. •
  7. Receiver
  8. •
  9. FrSky ARCHER PLUS R10+ User manual

FrSky ARCHER PLUS R10+ User manual

Version
1.0
Instruction Manual for FrSky ARCHER PLUS R10+ Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
● Dimension: 46.5*26.3*14.7mm (L*W*H)
● Weight: 13g
● 10 Configurable Channel Ports
CP1: PWM / SBUS Out / FBUS / S.Port / SBUS In
CP2-10: PWM / SBUS Out / FBUS / S.Port
● SBUS Out (Supports 16CH / 24CH mode)
● Operating Voltage Range: 3.5 -10V
● Operating Current: <100mA@5V
Specifications
The Archer line of receivers has been enhanced further with the addition of the new Archer Plus Series.
The Archer Plus Series receivers include some new features. Firstly an enhanced anti-RF-Interference capability
can offer a more solid RF performance, and this is in addition to existing anti-interfere performance in the spark
ignition process. These Plus series receivers are also with both ACCESS and ACCST D16 modes, where the RF
protocol is smart matched during the binding process on the radio. With the Black-Box function, some basic flight
data (like Power & Signal related) can be well preserved.
The R10+ receivers have 10 configurable channel ports, each channel port can be assigned as PWM, SBUS,
FBUS, or S.Port. The R10+ can be used as a Primary receiver in a redundant solution by setting a port as SBUS
In and connecting to any other FrSky receiver equipped with an SBUS Out port. With the FBUS protocol, the
Archer Plus series receivers can open up the possibility of seamlessly pairing with multiple telemetry devices
(XACT servos, ADV Sensors, etc.) as well as simplifying the builds setup. This receiver also supports full-range
signal strength with dual detachable antennas and guarantees optimal antenna reception and range.
Introduction
Working State
Status
Register
Register successfully
Bind
Work Normally
Failsafe
Red LED
On
Flash
Off
Off
On
Green LED
On
Flash
On
Flash
Off
Overview
46.5mm14.7mm
26.3mm
10
9
10/24CH Telemetry
2.4G Antenna
2.4G Antenna
AIN2 (max: 35V)
(Upgrade)
Version
1.0
Instruction Manual for FrSky ARCHER PLUS R10+ Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
Features
● Enhanced Anti RF-Interference capability with more solid RF performance
● Smart-matched ACCESS & ACCST D16 modes
● Supports basic Black-Box function
● 10 configurable channel ports (PWM, SBUS, FBUS, or S.Port)
● Supports signal redundancy (SBUS In)
● Full control range with telemetry (S.Port or FBUS)
● Anti-interference capability in the spark-ignition process
● Over-The-Air (OTA) FW update
● External battery/device voltage detection
● Control Range: Full range* with telemetry
(*Full Range: >2km, range may vary based on local conditions.)
● Voltage Measurement Range via AIN2 (External device): 0-35V
(Battery Voltage Divider Ratio: 1:10)
● Compatibility: FrSky 2.4GHz ACCESS / ACCST D16 capable transmitters
Follow the step below to finish the registration & binding procedure:
1. For TANDEM X20 as an example, enter into the Model, select RF System, turn on the internal module, select
status [ON] and ACCESS, Then determine the antennas (internal or external) and choose the RF power
according to the actual usage, the ACCESS receiver can be registered to the radio at the moment. (Notice: the
"Registration" process is not required while binding the receiver in ACCST D16 mode.)
2. Connect the battery to the receiver while holding the button on the receiver. The RED LED and GREEN LED
on the receiver will be on, indicating into the [Reg] status.
3. When it shows the Register ID, RX name and UID, click [Register]. The RED LED and GREEN LED on the
receiver will flash, and the transmitter displays [Registration OK ].
4. Power off the receiver.
5. Move the cursor to select any one of the 3 receivers and press [Bind].
6. Connect the battery to the receiver.
7. Select the RX, the GREEN will keep lit, then the transmitter displays [Bind successful].
Registration & Automatic Binding
Note: Once the receiver is registered, the button is not needed anymore in the binding process (ACCESS mode).
How to switch the S.Port/SBUS OUT/SBUS IN/FBUS
Select the FBUS/S.Port/SBUS Out/SBUS In for the
channel ports.
Enter into the [Set] of receiver.
Version
1.0
Instruction Manual for FrSky ARCHER PLUS R10+ Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
Note:
●
If the failsafe is not set, the model will always work with the last working status before the signal is
lost. That could cause potential damage.
●
When the failsafe is disabled on the RF module side, the failsafe set on the receiver side will be
applied.
●
SBUS port does not support the failsafe setting in No Pulses mode and always outputs signal.
Please set "Hold" or "Custom" mode for the SBUS port.
Version
1.0
Instruction Manual for FrSky ARCHER PLUS R10+ Receiver
FrSky Electronic Co., Ltd. www.frsky-rc.com Contact us : [email protected]
Add: F-4,Building C, Zhongxiu Technology Park, No.3 Yuanxi Road, Wuxi, 214125, Jiangsu, China Technical Support: [email protected]
There are 3 failsafe modes when the setting is enabled: No Pulse, Hold, and Custom mode.
●
No Pulses Mode: On loss of signal, the receiver produces no pulses on any channel. To use this mode, select
it in the menu and wait 9 seconds for the failsafe to take effect.
●
Hold Mode: The receiver continues to output the last positions before the signal was lost. To use this mode,
select it in the menu and wait 9 seconds for the failsafe to take effect.
●
Custom Mode: Pre-set to required positions on the lost signal. Move the cursor to the failsafe mode of the
channel and press Encoder, then choose the Custom mode. Move the cursor to the channel you want to set
failsafe On and press Encoder. Then rotate the Encoder to set your failsafe for each channel and short-press
the Encoder to finish the setting. Wait 9 seconds for the failsafe to take effect.
How to set Failsafe
A pre-flight range check should be done before every flight, in case the signal loss is caused by the reflection of
the signal by the nearby metal fence or concrete, and the shading of the signal by buildings or trees during the
actual flight. Under normal circumstances, in Range Check mode, the RSSI at 150m is about 45-50.
1. Place the model at least 60 cm (2 feet) above the non-metal contaminated ground (such as on a wooden
bench). The receiving antenna should be in a vertical position.
2. Ener the ETHOS system, move to the "RF System", scroll the Encoder to select "RANGE" mode and press
Encoder. In range check mode, the effective distance will be decreased to 1/30.
Range Check
How to switch SBUS channel mode
Enter into RX Settings, click [SBUS], then select SBUS-16 mode or SBUS-24 mode.
Note: Please do not do the binding operation in the near range while the firmware upgrading in progress.
Note: Update the firmware after the receiver getting registered (OTA).
Go to the [File manager], and select the FW, press the enter button, select [Flash RX by int.OTA]. Power on the
receiver, select the RX, go to the [ENTER], complete the flash process, the transmitter will display [Success].
Wait for 3 seconds, the receiver works properly at the moment.
About OTA function (ACCESS mode)

Other FrSky Receiver manuals

FrSky X8R User manual

FrSky

FrSky X8R User manual

FrSky TARANIS X9D User manual

FrSky

FrSky TARANIS X9D User manual

FrSky RX6R User manual

FrSky

FrSky RX6R User manual

FrSky V8FR-II User manual

FrSky

FrSky V8FR-II User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky TARANIS X9D User manual

FrSky

FrSky TARANIS X9D User manual

FrSky D8R-XP User manual

FrSky

FrSky D8R-XP User manual

FrSky D6FR User manual

FrSky

FrSky D6FR User manual

FrSky ACCESS XM User manual

FrSky

FrSky ACCESS XM User manual

FrSky Delta 8 User manual

FrSky

FrSky Delta 8 User manual

FrSky Archer R10 Pro User manual

FrSky

FrSky Archer R10 Pro User manual

FrSky ACCESS RX4R User manual

FrSky

FrSky ACCESS RX4R User manual

FrSky ARCHER PLUS Series User manual

FrSky

FrSky ARCHER PLUS Series User manual

FrSky Dragon Fire Series User manual

FrSky

FrSky Dragon Fire Series User manual

FrSky HORUS X10S User manual

FrSky

FrSky HORUS X10S User manual

FrSky D4R-II User manual

FrSky

FrSky D4R-II User manual

FrSky TARANIS X9D User manual

FrSky

FrSky TARANIS X9D User manual

FrSky R9 STAB OTA User manual

FrSky

FrSky R9 STAB OTA User manual

FrSky RX8R PRO User manual

FrSky

FrSky RX8R PRO User manual

FrSky X8R User manual

FrSky

FrSky X8R User manual

FrSky TD R18 User manual

FrSky

FrSky TD R18 User manual

FrSky 2.4GHz ACCESS R-XSR User manual

FrSky

FrSky 2.4GHz ACCESS R-XSR User manual

FrSky Archer GR8 User manual

FrSky

FrSky Archer GR8 User manual

FrSky DFT User manual

FrSky

FrSky DFT User manual

Popular Receiver manuals by other brands

Harman Kardon AVR 525 owner's manual

Harman Kardon

Harman Kardon AVR 525 owner's manual

American Fibertek RRM-30 Instruction manaul

American Fibertek

American Fibertek RRM-30 Instruction manaul

Yamaha CRX-332 owner's manual

Yamaha

Yamaha CRX-332 owner's manual

Sony HCD-U1BT - Receiver Component For Micro Hi-fi... Service manual

Sony

Sony HCD-U1BT - Receiver Component For Micro Hi-fi... Service manual

Denon AVR-2803 Code List

Denon

Denon AVR-2803 Code List

Vigitron Vi15016 installation manual

Vigitron

Vigitron Vi15016 installation manual

Sur-Gard SG Security Communications MLR2-DG installation manual

Sur-Gard

Sur-Gard SG Security Communications MLR2-DG installation manual

Onkyo HT-R410 Service manual

Onkyo

Onkyo HT-R410 Service manual

Onkyo HT-R518 instruction manual

Onkyo

Onkyo HT-R518 instruction manual

Terra Electronics OD003 manual

Terra Electronics

Terra Electronics OD003 manual

Fanimation WFR7998 SPECIFICATION AND INSTRUCTION SHEET

Fanimation

Fanimation WFR7998 SPECIFICATION AND INSTRUCTION SHEET

Pioneer VSX-430-K quick start guide

Pioneer

Pioneer VSX-430-K quick start guide

Philips MX1050D/22 Service manual

Philips

Philips MX1050D/22 Service manual

Tinysine AUDIO-B PLUS aptX TWS manual

Tinysine

Tinysine AUDIO-B PLUS aptX TWS manual

Raymarine AIS250 user guide

Raymarine

Raymarine AIS250 user guide

JVC KD-DV5000 Schematic diagrams

JVC

JVC KD-DV5000 Schematic diagrams

Denon AVR-3808CI Code List

Denon

Denon AVR-3808CI Code List

Kenwood 107VR instruction manual

Kenwood

Kenwood 107VR instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.