LOV™Technical Reference
8
Problem Probable Cause Fix
Auto filtration
won’t start. Ensure MIB is not in manual mode.
Ensure MIB cover is not pressing
against buttons.
Filter relay failed.
1.
2.
3.
Ensure MIB is in “A” automatic mode and
press the reset button.
Remove and replace cover.
Replace 24VDC filter relay (807-4482).
1.
2.
3.
MIB doesn’t
display A or vat
number.
An error has occurred and dis-
played character indicates error.
1. Check MIB Diagnostic codes, page 44 of
this manual.
1.
No power at MIB. Transformer failed in left compo-
nent box.
1. Check output on left transformer in left
component box; should be 24VAC. If not,
replace the transformer.
1.
MIB error will not
clear. Power surge or other electrical
problem.
1. Press the reset switch, top right corner of
the MIB, to reinitialize the CAN system. The
reset takes about 20 seconds per vat. The
MIB display should return to “A“, though it
may take more than one minute to do so.
1.
MIB alternating
“n” and “r”.Network error on the CAN bus
communication.
1. Ensure the CAN bus system is terminated
at BOTH ENDS (on the M2007 connector
J6 and on the ATO board connector J10)
with a resistor equipped 6-pin connector.
Ensure all 6-pin CAN connectors are
tight between the M2007 (J6 and J7),
MIB (J1 and J2), AIF (J4 and J5) and
ATO (J10) boards.
Check continuity between each color
wire on the CAN connectors into J7 on
the far right computer and J10 on back
of the ATO board (black to black, white to
white, and red to red), and ensure there
is no continuity between different color
wires (black to red, red to white, and
white to black).
Ensure black computer locator wires are
connected from ground to correct pin
position (see diagram 805-1656 on page
35 of this manual). Ensure all boards
have the corner ground wire attached
and tightened.
The locator pin in J2 of the AIF board is
either loose or in the incorrect position.
See the charts on pages 45-46 of this
manual for proper pin position.
In early units, it is possible that the resis-
tor could short. Disconnect power to
the unit, unwrap the resistor leads, and
ensure they are not touching.
1.
•
•
•
•
•
Troubleshooting the Manual Interface Board (MIB)