
- vii -
INF-TN3FLR-E
4.7. Zero Adjustment ······················································································ 26
4.8. Setting of unit ························································································· 27
4.8.1. How to set the unit system ············································································· 27
4.8.2. How to set the flow rate unit ··········································································· 28
4.8.3. How to set the total unit ················································································ 29
4.9. Output Setting ························································································· 30
4.9.1. Setting of flow rate range··············································································· 30
4.9.1.1. Setting of flow rate range (single range)···················································· 30
4.9.1.2. Setting of analog output at error (Burnout)················································· 32
4.9.1.3. Output limit ···················································································· 33
4.9.2. Setting the total (actual) ················································································ 34
4.9.2.1. Setting the total pulse (total rate, pulse width)············································· 34
4.9.2.2. Setting the preset value ······································································· 36
4.9.2.3. TOTAL mode (total reset, start, stop) ······················································· 37
4.9.2.4. Determining how to dispose of total at error (BURNOUT)······························ 38
4.9.3. Setting the DO output··················································································· 39
4.9.3.1. How to validate the total pulse output ······················································ 40
4.9.4. Setting the LCD indication············································································· 41
4.9.5. Setting the damping ····················································································· 42
4.9.6. Setting the low flow rate cutting ······································································ 43
4.10. Application operation of parameter ······························································· 44
4.10.1. Setting automatic 2 ranges············································································ 44
4.10.2. Setting the Bi-directional range ······································································ 46
4.10.3. Setting the Bi-directional auto 2 range ······························································ 48
4.10.4. Rate limit································································································ 50
4.10.5. Setting the DO output ················································································· 52
4.10.5.1. How to validate outputting the FULL SCALE 2········································· 52
4.10.5.2. How to validate the alarm output ·························································· 53
4.10.5.3. Setting the flow switch ······································································ 54
4.10.5.4. How to validate the total switch···························································· 56
4.10.5.5. How to validate the range over output and pulse range over output··················· 57
4.10.5.6. How to validate the output at the minus direction action ······························· 58
4.10.6. How to compensate the measurement value························································ 59
4.10.7. Setting of the operation mode ········································································ 60
4.11. MAINTENANCE MODE·········································································· 61
4.11.1. How to calibrate the analog output ·································································· 61
4.11.2. How to set the constant current output ······························································ 62
4.11.3. How to check the action of total pulses ····························································· 63
4.11.4. How to check the status output······································································· 64
4.11.5. How to validate the test mode (simulated flow rate output) ······································ 65
4.11.6. How to validate a serial transmission (RS-485)···················································· 67
4.11.7. ID No. setting··························································································· 69
4.11.8. How to confirm the software version································································ 69
4.11.9. Initializing setting parameters ········································································ 70
4.11.10. LCD backlight setting················································································ 71
4.11.11. How to set the detailed setting ······································································ 72
5. Mounting of detector ······················································································ 74
5.1. Detector mounting procedure ······································································· 74
5.1.1. Mounting of detector···················································································· 75
5.1.2. Image figure of mounting dimension ································································· 75