Fujiiryoki TREVI FW-107T User manual

FW-1000SA
INSTRUCTION
MANUAL
Alkaline ionizer
Thank you for purchasing our products.
The instruction manual says important matter for use.
Read carefully before use and use this product correctly.
keep this manual at a safe where you can consult it
whenever necessary.
FW-107T


Directory
Introduction How to install How to use Maintenance Other
Please follow the manual for safety 4
Before use 8
Name of each part 9
How to attach multi-branch faucet 13
Installation of product body 16
How to attach the delivery pipe 19
How to attach the drain hose 19
How to attach the water supply hose 20
How to use alkaline ionized water,
acid water, purified water
21
Check with ORP
23
Precaution for use 23
Measure the pH value of ionized water 24
Refill glycerophosphoric acid calcium 25
Cleaning inside the product 26
Maintenance 27
Exchange of cartridge 28
Q & A 31
Specification 34
3
…………………………………………
……………
…………………………………
………………………
………………
…………………
……………
……………………
…………………………
……………………………………
…………………………………
…………
…………
………………………………………
……………………
……………………………
………………………………………………
………………………………………

Please follow the manual for safety
4
<Examples of picture display>
mark refers to「prohibited actions」
mark refers to「Must」
「Do not disassemble」「No use near water place」
「Do not wet」「No water hands」「Fire prohibited」
「general acts」
「Unplug the power cord」
keep this manual at a safe where you can consult it whenever necessary after reading.
Improper use may result in injury or damage to property.*
* property refers to houses, household belongings, domestic animals and pets.
Improper use may result in serious injury or death
or damage.
This notes are the purpose of preventing you or those who are around from harm or
damage by using this product correctly.
The notes are classified as follow,
Read carefully and follow the notes for your safty.
Introduction
WARNING
CAUTION

5
WARNING
Introduction
In case the products drop into water, it may cause electric shock,
(1) Unplug the power cord,
(2) Raise the product,
(3) Ask the dealer for the repair.
Remove dust from the power cord.
Accumulation of dust on the power cord may cause fire due to insulation failure by
moisture.
※Unplug the power cord and wipe dust with dry cloth.
Plug the power cord firmly to the outlet.
Inadequate plug may cause electric shock or fire.
Unplug the power cord during maintainance.
(Electrification may occur)
Do not use this product for the water which is not approved as drinking water.
(Disconditioning of body may occur)
Do not use this product with incorrect voltage.
(Fire or electrification may occur)
Do not damage the power cord and power plug. (Do not do followings)
・Hold with staple ・Damage ・Process・Bend
・Twist ・Pull ・close to heating equipment ・Put heavy objects ・bundle
・Tucking (it may cause electric shock, fire)
※Grab the power plug and unplug it
※Ask the dealer for repair of power cord or power plug.
Do not use when the power cord and power plug are damaged or loose.
(electrification, fire may occur)
Do not wash with water or put water on this product
(leakage or electrification may occur)
Do not use in the bathroom or humid place.
(leakage or electrification may occur)
Do not unplug with wet hands
(electrification may occur)
Do not remodel, decompose, repair.
(Fire or electric shock may occur)
・Ask the dealer for the repair

6
Please follow the manual for safety
Introduction
CAUTION
Those who have following conditions should consult a doctor before drinking
ionized water.
・Persons with chronic disease, abnormal feeling or feeling weak of body.
・Persons on the cure under the doctor's supervision, especially have kidney failure.
Stop using and consult a doctor when you feel abnormal on the body or no
improvement of the symptom can be seen.
Person who drink ionized water should set ph8.5 first and drink a few cup of water
little by little.
Increase the pH and the amount of water after you get used to drinking ionized water.
・A feeling of unwellness may occur when you dirink strong ionized water from
the beginning.
Following conditions should consult a doctor before drinking acid water.
・Persons with sensitive (weak) skin.
・Persons who have allergy.
Stop using and consult a doctor when feel abnormal on the skin with acid water.
Use the ionized water, purified water or acid water immediately.
In case of storing water, store in the fridge with closed container and use within 2 days.
・General bacteria are easy to increase as fungicide in ionized water and purified
water is removed.
Drinking the stored water for a long time may cause disconditioning.
Flow the accumulated water inside the product in the beginning of use.
・Flow the water for 1 minute (a few cup ot water) and use the product in every use.
・In case of non-use more than 2 days, flow the water for 2 minutes and use.
Persons with renal disease(renal failure, Potassium excretion failure) are not
allowed to use.
Do not take a medicine with ionized water.
Do not drink the water more than pH.10 (It may cause disconditioning)
pH.9.5 water is recommended for drinking. Drink 0.5 to 1 liter per day as a guide of use.
Do not drink followings (It may cause a feeling of unwellness)
・Acid water ・The water from drain hose
・The water under cleaning
Do not put into the product except the accessory of Calcium glycerophosphate.
(It may cause a feeling of unwellness)
・Use the accessory or separate option.
Do not use except accessory of pH measurement solution
・Use the accessory or separate option.
Do not use the copper or aluminum container which is weak to alkali.
It may cause discoloration or damage to the container.

7
→
←
Introduction
・Do not use the hot water over 35℃in the product. (It may cause product malfunction)
・Do not use the hot water over 50℃in the branch faucet. (It may cause burn or
product malfunction)
Do not use ionized water, acid water, purified water as breeding water for fish.
The fish may die because of the change of environment.
Do not drink the water which pH measurement solution is included or do not put
them into eyes.
(It may cause a feeling of unwellness)
Do not drink the water when digital display or rinse lamp is blinking.
(It may cause a feeling of unwellness)
Do not put the pH measurement solution close to fire as it contains alchohol.
(It may cause fire)
Use accessory of pH measurement solution and examine the pH after installation
and no use for a long time. Use the product after the water of pH9.5 is not over
pH10 by the examination. Keep examining the water more than once a month.
Pull out the power plug by holding the actual power plug and not the cord.
(This may cause electrification, short circuits, or fire.)
Unplug the power cord when not using for a long time. (more than 1 week)
Ask the dealer when the product is installed in wall-mounted.
(It may cause an accident by the product dropping)
What is pH?
It indicates the amount of hydrogen in water and show whether the water is
alkaline or acidity.
Acidity Neutral Alkaline
(smaller number) (7) (bigger number)
What is ORP?
It indicates electric energy to oxidize or reduce material.
・Higher plus number is stronger to oxidize.
・Lower minus number is stronger to reduce.
CAUTION
●
●

8
Before use
●Use 3 types of water for each situation
In order to use well
PH adjustment button
Use pH
10.5 Cooking for the food which has strong scum.
Do not drink directly. 10〜11
Purified
water
Filtered water by a cartridge.
For medicine, milk, drinking.
※It is not decomposed by an electric current.
9.5
Alkali For daily drinking, coffee, tea, boiled food, soup. 9〜9.9
Acid
water
For face washing
Do not drink 4.5〜6.5
9.0 When getting used to drink, cooking rice. 8.5〜9.5
8.5
5.5
Beginning of drinking. 8〜9
●
●
●
●
●
Introduction
Eye-friendly digital display
・ Current created water condition can be seen easily on the digital display.
・ Show pH and ORP.
One-touch pH adjustment button.
Favorite pH water can be selected with one-touch.
Multi-branch faucet
・ Protect the product by the notification of safty valve in the area that is high water
pressure of tap water.
・ Protect the product by hot water shut-off function if the hot water is flowed by accident.
Accidental ingestion prevention function
・ Alkaline ionized water(for drinking) is created preferentially and prevent accidental ingestion
of acid water.
・ The alarm announce when undrinkable strong alkaline water and acid water is used.
Notification function of water purification cartridge exchange.
Cartridge exchange lamp blinks and lights up for the time for replacement of water
purification cartridge.
Specified pH may not be obtained by the area or water quality.
Especially the tap water containing more carbonate may not show the actual alkaline due to
the carbonate.
Carbonate is removed by boiling the alkaline water and actual alkaline is shown.
CAUTION
CAUTION
Attention

26
19
28
16
10
25
9
25
Hose
fixing
band
(2 units)
wall hanging woden
screw
(2 pcs)
pH measurement solution set
pH mesurement solution
pH color comparison paper chart
Dedicated cup
the numbers in this discription indicate
the page that the explanation is written.
Front cover
Water purification
cartridge
Delivery pipe
(Spout)
Adjuster
Operation panel
Calcium cap
Calcium case
Body
<Accessory>
Multi-branch
faucet
Delivery pipe
Drain hose
Fixing sucker
Cartridge
exchange seal
Calcium
glycerophosphate
Accessory for mounting
multi-branch faucet
spoon for calcium
glycerophosphate
Name of each part
Introduction

10
30
30
30
30
28
26
22
31
26
30
23
23
23
23
22
21
21
<Operation panel>
<Setting panel>
Operation panel
Setting panel
Power lamp
Power button
Rinse lamp
Refresh lamp
Cartridge exchange
lamp
the numbers in this
discription indicate
the page that the
explanation is written.
ORP display
button
Strong alkali
button
Alkali button
Purified water
button
Acidity button
Select button for
the type of cartridge
Select lamp for
the type of cartridge
Select lamp for
the life of cartridge
Select button for
the life of cartridge
Reset button for
replacement
of cartridge
Refresh button
Temperature rise
warning lamp
Name of each part
Introduction
Digital display part
pH value of generating ionized
water and ORP value is displayed.
(All the displayed value is indication)
※The displayed value of pH and
ORP is due to a given test water.
Actual created water may result
error due to the water quality and
the amount of flowing water.

11
<Mounting completion drawing>
Delivery pipe
water faucet
(Not in the accessories)
Multi-branch faucet
Water supply hose
Power plug
Power cord
Drain hose Fixing sucker
Drain hose
Water from here cannot drink.
Introduction

12
Name of each part
Packing
Hot water spout
Ionized water,
purified water,
tap water,
switching lever
Hose tightening cap……secure the water supply hose firmly to hose connection
Hose connection……connect the water supply hose
Branch faucet tightening cap……secure the branch faucet firmly to tap.
Ionized water, purified water, tap water switching lever……
「Ionized water, purified water」can switch.
Packing……Prevent water leakage from the connection of branch faucet and tap.
Safety valve
……
Water come out when the water pressure become too high inside the product.
Hot water spout……hot water come out from the spout when switching lever is set on
ionized water, purified water and hot water over 50℃flow.
Metal net……
Remove the accumulated garbage with brush when the amount of tap water,
ionized water, purified water is less or after using for a long time(more than 6 months)
●
●
●
●
●
●
●
●
How to use Ionized water, purified water, tap water switching lever
●
Hose tightening cap
<Multi-branch faucet> Branch faucet tightening cap
When use for
「The shower of
tap water」
When use for
「Regular tap water」
When use for
「Ionized water,
purified water」
Safety valve
Hose connection
Metal net
Introduction

13
How to attach multi-branch faucet
Multi-branch faucet is easy to attach.
The branch faucet prevent that hot water flow into the product by hot water
shut-off function when hot water(more than 50℃) is used by mistake.
Hot water shut-off function is released when the cock of tap water is switched
to water mode.
Water come out from safty valve and announce that the water pressure
inside the product is too high when water pressure of tap water is high or
the water pressure inside the product become about 500kPa(5kgf/cm2)
caused by clogging of dirt in the cartridge.
(Reduce the water pressure by squeezing the cock of tap water when water
come out from safty valve.)
Works
Multi-branch faucet is not attachable to following water faucet.
Diameter of
external thread
(more than 23mm)
Diameter of faucet
(more than 23mm)
less than 14mm
of forefront
With shower
Deformation
Special diameter
of screw
With sensor
Use ionized water, purified water less than 35℃.
(It may cause product malfunction.)
CAUTION
How to install

14
How to attach multi-branch faucet
Remove whole
the bubble.
Branch faucet
tightening cap
Internal
thread
Attach this part
Metal fitting
of bubble
Completion drawing
Use the mounting accessories that is fit to the diameter of faucet.
(It may cause water leak)
It may cause water leak from the mounting part if the faucet is made of plastic.
Recommend to change the faucet.
Notice
Packing
How to install
CAUTION
Turn the accessory
of external and
internal thread with
coin and attach the
Branch faucet
tightening cap
on the faucet.
Let branch
faucet
tightening
cap in.
Tighten the branch
faucet tightening
cap with fitting the
branch faucet
horizontally from
underneath.
External thread.
When use white external thread and the
height of screw doesn't fit, remove one of
the two packing and attach it.
In case there is bubble on
the head of faucet.

15
Completion drawing
Reattach the
screw
Screw
Screw
measure the diameter of pipe with the
mounting accessory of the board.
16mm 19mm
16mm
Branch faucet
tightening cap
Branch faucet
tightening cap
Tightening cap
for branch faucet.
Metal fitting
19mm
How to attach metal fitting of screws.
(When 16mm, 19mm of accessory do not fit.)
※metal fitting of screws is not included in
this product.
Ask the dealer where you purchased.
How to install
Let the 16mm or
19mm of mounting
accessory into the
pipe.
Let the branch
tightening cap
into the pipe.
The board of
adaptor assy
for branch
faucet.
Remove the
screw and let
the metal
fitting into the
branch
faucet.
Loose the
screw and
place the
branch faucet
onto the
faucet
horizontally
with pressing
and tighten it.
Do not
tighten too
much. (It
may make
a hole on
the faucet.)
Tighten the branch
faucet and cap.
Place the
chase to the
upper side
Place the branch
faucet onto the
faucet horizontally
and tighten the
branch faucet
tightening faucet.
When there is bulge on the
head of faucet.
When there is no course on
the head of faucet

16
Installation of product body
In case of installing the product on the place of the slope.
Adjuster:
The foot of
machine gets
longer when
turn it to the left.
Adjust the length of front leg
along with the tilt.
Front
Install the machine
horizontally.
Attention on installation
Foot
Water supply side
Drainage side
How to install
CAUTION
Install the procuct body on the horizontally.
Do not install this on unstable, wobbly, tilted place.
(It may cause injury due to dropping or falling the product.)
Do not install following place.
(It may cause deformation, discoloration, malfunction or failure.)
・Near the ones that get hot(over 60℃) or the place which the fire is used.
・Near or on top of the microwave, Electromagnetic cooker,Refrigerator.
・Where it is exposed to direct sunlight. ・Where the oil is attached.
・Where it is exposed to wind and rain or outdoors.
・Bathroom or where it is exposed to water, steam.
・Where there is a possibility of freezing
Do not extend the water outlet with commercial hose. (It may cause failure.)
Do not connect other equipment to water supply hose or drain hose.
(It may cause water leak or failure.)
Do not oppilate the water outlet, bend or twist or collapse the hose.
(It may cause water leak, failure or malfunction of pH)
Do not install hot-water supply equipment without check valve of water.
(It may cause failure to hot-water supply equipment.)
Do not install the product to the water faucet which is hot water only. (It may cause failure.)
Do not put anything in front of the product so that operation of button is easier.
Install the product without crushing the power cord, water supply hose, drain hose by the
product body.

17
<CAUTION>
Do not attache to the plywood or soft wall
as the weight is 5.5kg when the water is
full capacity.
2
1
In case of using over the wall.
Wooden pole
Make sure to use
specified wooden
screw.
<
In case of horizontal
>
<
In case of horizontal
>
Make sure to ask the dealer for the installation in case of using the product over
the wall. It may cause an accident by dropping the machine.
※Screw the wooden screws ineither
virtical one or horizontal one.
How to install
CAUTION
Cut「Screw hole position chart for the
wall」page on 18 along with dotted line,
put the tape and screw the wodden
screw in the accessory from the top of
the position chart. (Leave 8-9mm)
Hook the mounting hole
in the back to the
wooden screws.
8〜9mm
8〜9mm
16cm
For
horizontal
For virtical

18
[ Screw hole position chart for wall ]
Cut the seat along with cutoff line and use it for
the reference of screw hole position.
Make sure to save it after using.
160
mm
160
mm
………………………………………………………………………………………………………………
……………………………………………………………………………………………………………
Make a space over 11cm on the top so that
the calcium case can be removed when install
the product over the wall.
11cm and over Calcium case
Cutoff line

19
How to attach the delivery pipe
How to attach the drain hose.
Do not extend the water outlet with hose.
(It may cause water leak or failure)
Do not screw forcefully as the spigot is made of plastic.
(It may cause water leak or failure.)
When bend the delivery pipe after installation, grab the root and bend it with another hand.
Secure the drain hose with drain hose
Fixing sucker.
Delivery pipe
Screw the delivery pipe to the root.
Attach this part
The spigot part.
How to install
Attention
Attention
The difference in height of tip of
delivery hose and drain hose
should be 15cm to less than 40cm.
Drain hose should be lower than
the bottom of the product.
If the drain hose is too long, cut
and use it.
Make sure the drain hose does not
bend.
Do not extend the drain hose.
Drain hose
Drain hose fixing sucker
Difference in height
15cm to less
than 40cm
Delivery pipe

20
How to attach the water supply hose
When the Multi-branch faucet is attached to the faucet, make sure to keep enough
room so that the water supply hose can move right and left.
Remove the hose tightening cap
from the branch faucet, pass the water
supply hose through the branch faucet.
Make sure to tighten the hose
tighening cap.
4
Stick the water supply hose to the
root of hose connection port.
3
Cut the water supply hose to match
the distance between the body and
the branch faucet.
2
1
Hose tightening cap
Water supply hose
Water supply hose
Hose tightening cap
Attach this part
Make enoough space that the
faucet can move side to side.
CAUTION
Do not bend or twist the water supply hose.
(It may cause water leak)
Do not connect with the faucet of hot water only. (It may cause malfunction)
Do not use hot water when connected with mixing faucet.
(It may cause malfunction)
How to install
The thicker one is the water
supply hose, thin is the drain
hose. When the hose is
connected, check the
character of water supply and
drainage in the bottom of the
product.
Reccomend to band faucet
and water supply hose with
hose fixing band in
accessories.
Attention
Table of contents
Popular Other manuals by other brands

Red Sea
Red Sea MAX S-Series manual

Honeywell
Honeywell Searchline Excel installation guide

MadgeTech
MadgeTech HiTemp140-M12 user guide

STS
STS DL/N/RS485 Quick start installation guide

Fidelity Electronics
Fidelity Electronics SP-POS88IV SERIES Operation manual

Euphonix
Euphonix Max Air Control surface manual

Matsui
Matsui MDEHU10 instruction manual

Soundstream
Soundstream PICASSO PCX2.180 owner's manual

Hozelock Cyprio
Hozelock Cyprio Cascade 1500 Installation and operating instructions

DXV
DXV AT200 LS SpaLet installation manual

HERMOS
HERMOS LFM LP Reader Customer's manual

Advanced ID
Advanced ID PR100 user manual