2009.02.10 13
Troubleshooting with the receiver unit display
INDOOR UNIT (Option)
Error is displayed on the wired and
wireless remote control.
FILTER Lamp (Red)
TIMER Lamp
(Orange)
OPERATION
Lamp (Green)
MANUAL AUTO
Lamps show error contents by flashing as follows.
OPERATION
Lamp
TIMER
Lamp
FILTER
Lamp Error contents
2 times
Indoor signal error
3 times
4 times
5 times
8 times Wired remote control abnormal
2 times 2 times Indoor room temperature sensor error
2 times 3 times Indoor heat exchanger temperature
Indoor heat exchanger temperature
sensor (middle) error
2 times 4 times sensor (inlet) error
2 times 6 times Float switch operated
3 times 2 times Outdoor discharge pipe temperature
sensor error
3 times 3 times sensor (outlet) error
3 times 4 times Outdoor temperature sensor error
3 times 7 times Heat sink thermistor (Inverter) error
3 times 8 times Compressor temperature sensor error
3 times 2 times 2-way valve temperature sensor error
3 times 3 times 3-way valve temperature sensor error
3 times 4 times Outdoor heat excahnger temperature
Outdoor heat excahnger temperature
sensor (middle) error
3 times 5 times Heat sink thermistor (P.F.C.) error
4 times 2 times Indoor manual auto switch abnormal
4 times 4 times
Power supply frequency detection error
5 times 2 times IPM protection
5 times 3 times CT error
5 times 5 times Compressor location error
5 times 6 times Outdoor fan error
5 times 7 times Connected indoor unit abnormal
5 times 8 times Outdoor unit computer communication
error
5 times 2 times Inverter error
6 times
2 or 3 times
Indoor fan abnormal
7 times 2 times Discharge temperature error
7 times 3 times Excessive high pressure protection
on cooling
7 times 4 times 4-way valve abnormal
7 times 5 times Pressure switch abnormal,
Pressure sensor abnormal
7 times 6 times Compressor temperature error
7 times 7 times Low pressure error
8 times
2 or 3 times
Active filter abnormal
8 times 4 times P.F.C. circuit error
9 times 2 times
Refrigerant circuit address set-up error
9 times 3 times Master unit, Slave unit set-up error
9 times 4 times
Connected indoor number set-up error
Flash means "0.5 second on / 0.5 second off".
off
off
off
off
8 times 6 times P.F.C. PCB error
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
off
3rd Lamp (Red)
REMOTE CONTROL
SIGNAL RECEIVER