2016.01.07
ERROR DETECTION
8
If you use a wired type remote control,
error codes will appear on the remote control display.
If you use a wireless remote control,
the lamp on the photodetector unit will output error
codes by way of blinking patterns.
See the lamp blinking patterns and error codes in the table below.
An error display is displayed only during operation.
Error display Wired
remote
control
Error code
krameRNOITPIRCSEDedoM
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(1) (1)
Communication
Serial communication error •
When the indoor unit cannot receive the signal from the branch unit
•
When the branch unit cannot receive the signal from the indoor unit
(1) (2)
Communication
Remote control
communication error
•Wired remote control communication error
(1) (5)
Communication
Scan error
•
Check operation incompletion error (normally, operation disabled)
(2) (1)
Function setting
Initial setting error
•Wiring mistake
(2) (2)
Function setting
Indoor unit capacity error
•Indoor unit capacity error
(2) (3)
Function setting
Connection disabled (series error)
•Combination error
(2) (4)
Function setting
Connection unit number error
•Connection unit number error (indoor unit)
•Connection unit number error (branch unit)
(3) (2) Indoor unit Indoor unit main PCB error
•Indoor unit PCB Model information error
(3) (5) Indoor unit Manual auto switch error
•Manual auto switch error
(4) (1) Indoor unit Room error
•Inlet thermistor error
(4) (2) Indoor unit Indoor unit Heat Ex. sensor error
•Indoor unit Heat Ex. Middle thermistor error
(5) (1) Indoor unit Indoor unit fan motor error
•Main fan motor lock error
•Main fan motor revolution speed error
(5) (3) Indoor unit Water Drain error
•Drain pump error
(5) (15) Indoor unit Indoor unit error
•Indoor unit error
(6) (2) Outdoor unit Outdoor unit main PCB error
•Outdoor unit PCB Model information error
•Outdoor unit PCB microcomputer communication error
(6) (3) Outdoor unit Inverter PCB error
•Inverter error
(6) (4) Outdoor unit Active filter error,
PFC circuit error
•Voltage error stoppage permanently
•Voltage error (can restore)
•Over current protected operation stoppage permanently
•PFC hardware error
(6) (5) Outdoor unit IPM error
•Trip terminal L error
(6) (10) Outdoor unit Display panel error
•Microcomputers communication error
(7) (1) Outdoor unit Discharge thermistor error
•Discharge thermistor 1 error
(7) (2) Outdoor unit Compressor thermistor error
•Compressor thermistor 1 error
(7) (3) Outdoor unit Outdoor unit Heat Ex.
Sensor error
•Outdoor unit Heat Ex. liquid thermistor error
(7) (4) Outdoor unit Outdoor thermistor error
•Outdoor thermistor error
(7) (5) Outdoor unit Suction Gas thermistor error
•Suction Gas thermistor error
(7) (7) Outdoor unit Heat sink thermistor error
•Heat sink thermistor error
(8) (2) Outdoor unit Sub-cool Heat Ex. gas
thermistor error
•Sub-cool Heat Ex. gas inlet thermistor error
•Sub-cool Heat Ex. gas outlet thermistor error
(8) (3) Outdoor unit Liquid pipe thermistor error
•Liquid pipe thermistor 1 error
(8) (4) Outdoor unit Current sensor error
•Current sensor 1 error (stoppage permanently)
(8) (6) Outdoor unit Pressure sensor error
•Discharge pressure sensor error
•Suction pressure sensor error
•High pressure switch 1 error
(9) (4) Outdoor unit Trip detection
•Trip detection
(9) (5) Outdoor unit compressor motor control error
•Rotor position detection error (stoppage permanently)
(9) (7) Outdoor unit Outdoor unit fan motor 1 error
•Duty error
(9) (9) Outdoor unit 4-way valve error
•4-way valve error
(10) (1)
Refrigerant system
Discharge temperature 1 error
•Discharge temperature 1 error
(10) (3)
Refrigerant system
Compressor temperature error
•Compressor 1 temperature error
(10) (5)
Refrigerant system
Pressure error 2
•Low pressure error
(13) (2) Branch box Unit flow divider error
•EEPROM access error
•Equipment type information error
•Serial communication error to outdoor unit
•Branch units serial communication error
•Serial communication error to indoor unit
•Liquid pipe thermistor error
•Gas pipe thermistor error
•Expansion valve full closure operation error
•Remote controller communication error
•Branch unit error
•
Display mode : 0.5s ON / 0.5s OFF, ( ) : Number of flashing : 0.1s ON / 0.1s OFF
Wired remote control display (Option)
Error code