En-1
OPTIONAL KIT INSTALLATION (OPTION)
This air conditioner can be connected with the following optional kits.
• Wired remote controller
• Simple remote controller
• External connect kit
BEFORE INSTALL WIRED REMOTE CONTROLLER
• When you use wired remote controller, some functions may not be used.
CAUTION
• Before installing, be sure to disconnect all power supply.
• Don’t touch the heat exchanger.
• During installing or removing operation, be sure not to have wire caught by parts or
draw it hard. Or it may result troubles to the air-conditioner.
• Avoid place in direct sunlight.
• Select place that will not be affected by the heat from a stove, etc
• Before setting up the optional kit, please con rm whether air-conditioner can receive
the signal.
• Do not connect the wired remote controller to the terminal for power supply.
• When connecting the wired remote controller with the indoor unit, use the connecting
cable (supplied with wired remote controller or simple remote controller).
• Recommended cable length of wired remote controller is 32 ft. (10 m). Make sure to
do insulate of connecting part when extended the cable.
Do not connect power supply with the terminal.
INDOOR UNIT
PCB
TERMINAL
INSTALLATION WORK
Remote controller cord modi cation
(1) Use a tool to cut off the terminal on the end of the remote controller cord, and then
remove the insulation from the cut end of the cord.
(2) Connect the remote controller cord and connecting cord.
(supplied with wired remote controller)
Important: Be sure to insulate the connection between the cords.
Connecting cord
White
Red
White
Red
Black
Black
Insulated
connection
Remote
controller cord
Remote
controller cord
25/32 in.
(20 mm)
Installing wired remote controller terminal /
external connect kit terminal (sold separately)
(1) Remove the screw on the control box as shown on the top right of the figure below.
(2) Release both bottom clasps at the sides in the direction of the arrow as circled in
the bottom left of the figure below. Pull and remove the cover.
(2)
(1)
Cover
(3) Connect the wired remote controller terminal / external connect kit terminal (sold
separately) to the specified terminal on the board as shown below. Please connect
to the connector with necessary function according to the actual usage.
(4) After connecting each terminal, thread the cables through the notch as circled on
the bottom right of the figure below.
(3) Control input (Operation/
Stop or Forced stop) con-
nector
: CNA01(White) *
(3) Wired remote controller
connector
: CNC01(White) *
* : Symbol indicating the location printed on the board
(3) Error Status output
connector
: CNB02(Black) *
(3) Operation status
output connector
: CNB01(White) *
(4)
(5) Install the control box cover as shown below.
(Align the cover with the upper and lower right corners as indicated by the triangular
symbols on the figure.
Insert the clasps on the cover into both sides at the bottom of the two dotted
circles.)
• When installing the control box cover, make sure that the cables are not caught as
shown in the detail view.
(6) Install one screw.
(7) Screw the earth wire of wired remote controller as shown in the figure.
(AUSTRALIA model only).
(7)
(5)
(5)(6)Cover
Detail view
Installing communication box
Removing intake grille
(1) Remove the screws (x4). (Use the same screws when installing.)
(2) Pull the control box cover towards you and remove.
(1)
(1)
(2)
(1)
(1)
(3) Remove the connectors (x4).
• Remove and pull off the lock at the side of the connector insertion part.
9333005041_IM.indb 8 11/6/2013 10:33:02 AM
AIR CONDITIONER
OPTIONAL PARTS
External connect kit
,167$//$7,21 0$18$/
For authorized service personnel only.
Supplemental Manual
En-2
CAUTION
• Be careful not to damage the parts on the board.
Otherwise, it will cause malfunction.
Connector number: CN 5
Connector number: CN 4
Connector number: CN 3
Connector number: CN 7
* : Symbol indicating the location printed on the board
(4) Remove the wires from the three fixtures. (See the figure below)
• Leave the thick green wire in fixture C and remove the rest of the wires.
CAUTION
• Do not pull the wires forcibly.
You may damage them.
Fixture A
Before After
Fixture B
Fixture C
Fixture C
(5) While pulling the control box towards you, remove in the right direction.
• Do not remove the thermistor.
• Do not damage the terminals on the removed wires. (See the figure below)
Thermistor
Control box
Terminals
Control box
(5)
Installing communication box
(1) Install the communication box on the main unit and secure it with the provided
screw at the location shown below.
View A (Detail view)
Screw
Motor cover
View A (Detail view)
(2) Use the hole on the motor cover and secure the wire from the communication box
with the provided cable tie.
(See the figure below)
Cable tie
Cut away the tip of
the cable tie.
Hole
Installing control box
(1) Set the control box toward the bottom so that it touches the motor cover from the
right.
Insert the protruding part of the main
unit on the  xture (1 location) into
the control box.
Control box
• The installation method of the control box is different for each destination country.
(See figure below)
(When installing, reuse the screw that was removed in Removing control box.)
(2) Secure the control box with a screw. (Use a long screw.)
9333005041_IM.indb 9 11/6/2013 10:33:06 AM
En-3
(3)
(2)
(3) Fasten the earth wires of the heat exchanger together as shown in the left figure
above. (Use a short screw here.)
(4) Hitch the wires onto the fixtures as shown in the oval circles below. Then connect
the connectors in the squares to the terminals respectively.
(Each terminal should form a pair with a connector.)
CAUTION
• Ensure that the connector is properly inserted.
Otherwise, it may result in erroneous operation.
• Be careful not to damage the parts on the board.Otherwise, it will cause malfunc-
tion.
(4)
(5) Fasten the earth wire (green) in the communication box together with the earth
wire (green) on the board of the control box as shown below and in the bottommost
figure of the previous page.
(5)
(6) Install the cover of the control box onto the inner side of the rib as shown below.
CAUTION
• Do not cut or tuck the wires with the electrical component box cover.
An electric shock may occur if the wires are damaged.
(7) Tighten with screws to prevent the cover of the control box from falling off.
(When installing, reuse the screws that was removed in Removing control box.)
(7)
(7)
(6)
(8) Paste protect seals (2 locations) to prevent the wires from sticking out.
(8)
9333005041_IM.indb 10 11/6/2013 10:33:08 AM

Other Fujitsu Cables And Connectors manuals

Fujitsu PB-91469G-LS-256BGA User manual

Fujitsu

Fujitsu PB-91469G-LS-256BGA User manual

Fujitsu CFD5GRUDB3 User manual

Fujitsu

Fujitsu CFD5GRUDB3 User manual

Fujitsu UTY-XWZX User manual

Fujitsu

Fujitsu UTY-XWZX User manual

Popular Cables And Connectors manuals by other brands

Staubli RobiFix Assembly instructions

Staubli

Staubli RobiFix Assembly instructions

COMSOL HD102 user manual

COMSOL

COMSOL HD102 user manual

Allen-Bradley 2090-SCVG50-0 Installation and handling instructions

Allen-Bradley

Allen-Bradley 2090-SCVG50-0 Installation and handling instructions

EBECO T-18 installation instructions

EBECO

EBECO T-18 installation instructions

Masimo LNOP MP Series manual

Masimo

Masimo LNOP MP Series manual

Lindy 43376 user manual

Lindy

Lindy 43376 user manual

Sartorius YCC01-USBM2 installation instructions

Sartorius

Sartorius YCC01-USBM2 installation instructions

Raychem t-100 manual

Raychem

Raychem t-100 manual

Burndy Continental Industries thermOweld CC-99 instructions

Burndy

Burndy Continental Industries thermOweld CC-99 instructions

ELEKTRA SelfTec 16 installation manual

ELEKTRA

ELEKTRA SelfTec 16 installation manual

Philips SWV2516W Specifications

Philips

Philips SWV2516W Specifications

AV Access 4KSP12-P user manual

AV Access

AV Access 4KSP12-P user manual

PCB Piezotronics 010G05 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 010G05 Installation and operating manual

CMP C2K installation instructions

CMP

CMP C2K installation instructions

HSS Hire Hire-Weld HW890 Operating & safety guide

HSS Hire

HSS Hire Hire-Weld HW890 Operating & safety guide

SECO-LARM Enforcer CA-161R Specification sheet

SECO-LARM

SECO-LARM Enforcer CA-161R Specification sheet

Lindy 43099 user manual

Lindy

Lindy 43099 user manual

Panduit FK2BJ installation instructions

Panduit

Panduit FK2BJ installation instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.