Fuling Inverter DZB200 Series User manual

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 1/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 2/54
目 录
Appendix A Standard Specifications 82
Appendix B Serial Communications 85
Appendix C Dimensions 98
Appendix D Accessories List 100
1
Chapter 1 Safety and Cautions
7Chapter 3 Mechanical and Electrical Installation
6
Chapter 2 Product Introduction
17
Chapter 4 Operation and Display
22
Chapter 5 Function Parameters List
34
Chapter 6 Parameter Description
73
Chapter 7 Fault Diagnosis and Countermeasures
81
Chapter 8 Quality Guarantee
F0 Basic Function Parameters 34
F1 Motor Parameters 42
F2 Input and Output Terminal Function Parameters 46
F3 Human Machine Interface Parameters 54
F4 Application Function Parameters 57
F5 Protection Parameters 66
F6 Communication Parameters 69

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 3/54
-1-
Preface
DZB DZB200&300T hank you f or cho os in g hig h -perf orm ance A C Motor Driv es .
Series are manufactured by adopting high-q uality components, material and incorporating
the latest microprocessor technology available.
Getting Started
This manual will be helpful in the installation, parameter setting, troubleshooting, and
daily maintenance of the AC motor drives. To guarantee safe operation of the equipment,
read the following safety guidelines before connecting power to the AC drives. Keep this
operating manual handy and distribute to al l users for reference.
Series
ATTENTION:
DANGER!
WARNING!
WARNING!
ATTENTION:
CAUTION:
CAUTION:
CAUTION:
Always read this manual thoroughly before using series AC Motor Drives.
AC input power must be disconnected before any maintenanc e.
Do not connect or disconnect wires and connectors while power is applied tothe circuit.
Maintenance must be performed by qualified technicians.
To avoid personal injury, do not remove the co ver of the AC motor drive until all of the
digital keypad "DISPLAY LED" lamps are off. The DC-link capaci tor remains charged
with a hazardous voltage even after input power is removed.
Grounding the DZB100B drive i s done by
.
There are highly sensitive component s on the printed circuit boards. These components are
especial ly sensitive t o E SD (ele ctrostatic disch arge). ,do not
touch components or the circuit boards until sta tic control precautions have been taken.
Never connect the main circuit output terminal s U, V, and W directly to the AC main circuit
power supply as .
Do not apply the antirust to screws for fast ening drives; Please clean the drives and screws
with dry cloth or alcohol, not with synthetic cleaner. Fasten the screws with washers and
rated torque lest the enclosure corners of d rives be distorted.
DZB
connecting the Earth Ground to the drive
ground terminal
To avoid damage to the drive
this will damage the drive
This manual is for DZB200&DZB300 SeriesAC M otor Drive.
Preface
DZB Series
!WARNING

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 4/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 5/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 6/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 7/54
Chapter 3 Mechanical and Electrical Installation
3. 1 Mechanical Installation
1) Ambient temperature: Ambient temperature influences the inverter life greatly, so it should be within
the range of -10 ~50 .
2) Mount the inverter in a flame retardant s urface and the clearance around the inverter shall be enough
because the inverter will generate lots of heat during runni ng, besides mount the inverter on the base
vertically with screws.
3) Mount in the location where vibration is le ss than 0.6G; the inverter shall be far away from impact ing
lathe.
4) Please do not install the inverter in the place with direct sunlight, high humidit y and water.
5) Mount the inverter in the location free o f corrosive gas, explosive gas or combustible gas.
6) Mount the inverter in the location free of oi l dirt, dust, and metal powder.
1. Installation Environment
2.Installation Location
℃ ℃
D Z B
up
right
A
≥100mm
≥100mm
A
D Z B
D Z B
Note: No need to consider the dimension
A for inverter of 22kW or below.
A shall be bigger than 50mm for the
inverter of 22kW or above
Note: Install an airflow- guidance
plate for the up and down installation
of inverters.
Fig.3-1 DZB Series Inverter Installation Location
The user shall focus on the heat dissipation issues when installing the inverter, and pay attention to the
following points:
1) Install the inverter vertically so th at the heat may be expelled from the top, but do not install the
inverter upside down. When two Variable Speed Drives are mou nted up and dow n, an air flow
diverting plate should be fixed in between as shown in Fig. 3-1.
2) Installation space is shown in Fig.3-1 so as to ensur e the heat dissipation space, but consider the
heat dissipation of other components when placing the i nverter.
3) The installation bracket must be flame retardant.
4) Install the heat sink outside of the cabinet if the i nverter is installed in the area with metal powder.
And in this case, the space inside the sealing cabi net shall be big enough.
Nameplate
D Z B 3 0 0 B0015 L4 A
Function level code: A -braking unit inside
B -non braking unit
Input voltage
Freq. Range
Applicable motor capacity
Series General-Purpose Model
Fan&Pump Model
Seri es name Serie s
2-220V 4-400V 6-660V
L 0-600.0Hz
0015 1.5KW
B:
P:
: DZB300
:
: :
: 为
:
Description ofACMotor Drive Model:
Production number
Production month
Production year
8 8 8 81 00 6
Description of Serial Number::
2.2 Nameplate Information
- 7 - - 8 -
Install at ion of s i ng le i nv erter Up and down i nstal lation of i nv erters
Chapter 2 Product Introduction
DZB Series Chapter 3 Mechanical and Electrical Installation
DZB Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 8/54
3.2 Electrical Installation
1.Applicable devices and recommendable wiring of main circuit:
0005L2
0007L2
0015L2
0022L2
0037L2
0007L4
0015L4
0022L4
0037L4
0055L4
0075L4
0110L4
0150L4
0185L4
0220L4
0370L4
0450L4
0300L4
0550L4
0750L4
0930L4
1100L4
1320L4
1600L4
1870L4
2000L4
2200L4
2500L4
2800L4
3150L4
4000L4
5000L4
6300L4
0.55
0.75
1.5
2.2
3.7
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
93
110
132
160
187
200
220
250
280
315
400
500
630
70
*
2(150)
95*2(185)
120*2(240)
150*2(300)
185*2(370)
185*2(370)
INPUT(RST)
Air Circuit
Breakers
MCCB
Wire Size(mm )
2
Control
Terminal
0.5
0.75
DZ20-630(500A)
DZ20-630(600A)
DZ20-400(400A)
DZ20-400(350A)
DZ20-400(250A)
DZ20-200(200A)
DZ20-100(100A)
DZ20-100(80A)
DZ20-100(63A)
DZ20-100(50A)
DZ20-100(32A)
DZ20-100(16A)
DZ20-100(32A)
DZ20-100(16A)
DZ20-800(800A)
DZ20-1250(1000A)
DZ20-1250(1250A)
Magnetic
Contactor
MC
Applicable
Motor
(KW)
MODEL
DZB300
Series
CJ20-16
CJ20-40
CJ20-16
CJ20-40
CJ20-63
CJ20-100
CJ20-160
CJ20-250
CJ20-400
CJ20-630
CJ20-800
CJ20-500*2
CJ20-630*2
Power
Terminal
1.5
2.5
4
4
1.5
2.5
4
1.5
2.5
4
1.5
2.5
4
4
6
6
6
6
88
10
10
16
16
16
25
25
25
35
16
*
2(35)
25*2(50)
25*2(50)
25*2(50)
35*2(70)
35*2(70)
35*2(70)
50*2(95)
50*2(100)
50*2(95)
50*2(100)
70
*
2(150)
70*2(150)
95*2(185)
120*2(240)
150*2(300)
185*2(370)
185*2(370)
DC
Reactor Breaking
Terminal
- 9 - - 1 0 -
2. Wiring Diagram of Peripheral Equipment
Pow er Supply
Breaker or
Leakage Sw itch
M agnetic
Contactor( M C)
Input AC
Reactor(AC)
InputSide
Interference
Filter
Braking Resistor
Pow er-factor-im proving
D C Reactor(D C)
G rounding
Inverter
O utput AC
Reactor(AC)
O utput Side
N oise Filter
M otor
G rounding
Chapter 3 Mechanical and Electrical Installation
DZB Series
Chapter 3 Mechanical and Electrical Installation
DZB Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 9/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 10/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 11/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 12/54
Chapter 4 Digital Keypad Operation
- 1 7 - - 1 8 -
4 . 1
Description of the Digital Keypad
●Digital Keypad Parts and Functions
This digital keypad module includes two parts: display panel and a keypad. The display panel
allows the user to program the AC drive, as well as view the different operating parameters. The
keypad is the user interface to theAC mot or drive. Refer to the following figure for a description
of the different parts.
Jog key
Run key
Digital display
Up and down keys
Program key
Function / Data key
Stop / Reset key
Forward / Reverse key
Function indicator
▲
▲FUNC
DATA
PRGM
RESET
FWD
REV
JOG
RUN STOP
FWD REV
RUN STOP JOG
FW D
RE V
FUNC
DATA
JOG
JOG/
Used to start the AC drive, then run at the jog frequency.
When modify parameter, can select modified bit of the parameter.
STOP
Explanation of Screen Display
1. ( efer to F3.05):Explanation of Displayed Messages on Running status r
Fig. 4-1 Operation Panel Schematic Diagram
Forward / Reverse
Used to toggle between forward and reverse operation.
Pressing this key will cause the motor to ramp down to 0 Hz and then ramp up to the preset
speed in the opposite direction.
Function / Data
Displays information on theAC drive status such as the reference frequency,output
frequency, or output current in the normal mode. While the drive is in the Program Mode,
press this key once to display the current paramet ers.
After changing the parameters, press th is key again to store the new parameters.
Up / Down
Press the "Up" or "Down" button to change parameter settings .
These keys may also be used to scroll through different operating val ues or parameters.
Stop
Used tos top theAC drive operation.
If the AC drive has stopped due to a fault, press this button to reset the drive.
Run
Used tos tart theAC drive operation.
This key has no effect when the drive is set to terminal run.
PRGM
RESET
Program / Reset
First-stage menu entry or exit.
Key Description
RUN
Setting frequency
Running frequency
Output current
Output voltage
Running speed
Output power
Output torque
DC bus voltage
PID setpoint
PID feedback
Input terminal status
Output terminal status
VI value
CI value
Current segment of
multi-speed control
Operation
Displayed
Symbol Displayed Message
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key
“ ”
QUICK
JOG
FUNC
DATA
Press key
“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
QUICK
JOG
FUNC
DATA
Press key“ ”
Chapter 4 Operation and Display
DZB Series
Chapter 4 Operation and Display
DZB Series
QUICK
JOG
FUNC
DATA
Press key“ ”

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 13/54

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 14/54
DZB S iDZB S i

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 15/54
- 2 3 - - 2 4 -
F0.13 AVR selection
0 I nva lid
:
1 Valid all the time
:
113 .
※
F0 Basic Function Parameters
Function
Code Name Setting Range Modifi
cation
Serial
No
F0. 00 C ontr o l mode
0 Speed sensorless vector
control (SVC)
:
1 V/F c ontrol:
1
F0.01 Command source
selection
0 Ke yb o ard
:
1 Ter minal
:
2 Communication
:
0
F0.02 Keyboard and terminal
UP/DOWN setting 1 Valid, and inverter does not
memorize when power down
:
2 I nval id
:
0
F0.03 Frequency command
Selection
0 Ke yb o ard
:
4: Multi-speed
5: PID control
6: Communication
1 VI:
2 CI
:
3 V I+ CI
:0
F0.04 Maximum output frequency 10.00 600.00Hz
~50.00Hz
F0.05 Upper limit frequency F0.06 F0.04
~50.00Hz
F0.06 Lower limit frequency 0.00 Hz F0.05
~0.00Hz
F0.07 Keyboard frequency setting 0. 00 Hz F0.04
~50.00Hz
F0.08 ACCEL time 1 0.1 3600.0s~10.0s
F0.09 DECEL time 1 0.1 3600.0s~10.0s
F0.10 Operation direction
selection
0 Operating at default direction:
1 Operating at reverse direction
:
2 NO inverse operating
:
2
F0.11 Carrier frequency setting 1.0 15.0k H z
~Set by
model
F0.12 Functional parameters
restoration
0 NO operation
:
1 Restore default value:0
●0.
1.
※2.
3.
4.
5.
6.
7.
8.
9.
10 .
11.
12 .
●
※
※
※
※
※
※
※
●
●
●
2 Delete failure records
:
Function
Code Name Setting Range Modifi
cation
Serial
No
2 Invalid during deceleration
:
F0.14 Start Mode
0 Direct s tart:
1 DC braking first and then start
:
2 Running speed pic k-up and
then start
:
0
F0.15 Start frequency 0.00 10. 00Hz~0.50Hz
F0.16 Hold time of start
frequency 0.0 50.0s~0.0s
F0.17 Braking current
before starting 0.0 15 0.0%
~0.0%
F0.18 Braking time
before starting 0.0 50.0s~0.0s
F0.19 Stop Mode
0 DECEL Stop
:
1 Free run S t op:0
F0.20 Beginning Frequency of
braking 0.00 F0. 04~0.00Hz
F0.21 Waiting time of braking 0.0 50.0s~0.0s
F0.22 DC braking current 0.0 15 0.0%
~0.0%
F0.23 DC braking time 0.0 50.0s
~0.0s
F0.24
Dead time between
forward and reverse 0.0 3600.0s
~0.0s
F0.25
Terminal command
protection when
power on
0 Terminal command invalid
when power on
:
1 Terminal command valid when
power on
:0 1
~
F1.00 Inverter model
0 B m odel:
1 P m ode l
:
F1.01 Motor rated power 0.4 900.0kW
~
50.00Hz0.01Hz F0.04
~
Motor rated frequency
0 36000rpm
~Motor rated speed
0 46 0V~
Motor rated voltage
0.1 1000.0A
~
Motor rated current
0.001 65.535
~Ω
Motor stator resistance
F1.02
F1.03
F1.04
F1.05
F1.06
14 .
15 .
16 .
17 .
18 .
19 .
20 .
21 .
22 .
23 .
24 .
25 .
26 .
27 .
28 .
29 .
30 .
31 .
32 .
※
※
※
※
※
※
※
※
※
※
※
※
●
●
●
●
●
●
●
F1 Motor Parameters
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
F1.07 Motor rotor resistance 0.001 65.535~ Ω
F1.08 Motor stator/rotor
inductance
0.1 6553. 5mH
~
33 .
34 .※
※
Set by
model
Set by
model
Default
Value
Default
Value
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series
0 Valid, and inverter memorize
when power down
:
Ch t 5 F ti P t Li t
DZB Series
Ch t 5 F ti P t Li t
DZB0 Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 16/54
- 2 5 - - 2 6 -
Function
Code Name Setting Range Modifi
cation
Serial
No
F1.09 Mutual inductance of
motor stator/rotor 0.1 6553.5mH
~
F1.10 No-load current 0.01 655.35A
~
F1.11
Self-learning of
motor parameters
(Invalid for DZB200)
0 NO operation
:
1 Self-learning
:complete tuning
2:static tuning Self-learning
0
F1.12 Speed loop proportional
gain1 0 1 00
~30
F1.13 Speed loop integral time1 0.01 10.00s
~0.50s
35 .
36 .
37 .
38 .
39 .
F1.14 Switching low
point frequency 0.00Hz F1.1 7
~5.00Hz 40.
F1.15 Speed loop proportional
gain 2 0 1 00
~25 41.
F1.16 Speed loop integral
time 2 0.01 10.00s
~1.0 0s 42.
F1.17 Switching high
point frequency F1.14 F0.04
~10.00Hz 43.
F1.18 VC slip compensating
factor 50 % 200%
~100% 44.
●
※
※
※
※
※
※
※
※
※
F2.00 On-off signal filter times 1 10
~5 51.
F2.01 S1 Terminal Function
Selection
0:No Function
1:Forward
52 .
F2.02 253 .
※
●
●
1
S2 Terminal Function
Selection
F2 Input and Output Terminal Function Parameters
Set by
model
Set by
model
F1.19 Upper torque limit setting 0.0 200.0%(inverter rated current)
~150.0% 45.
F1.20 V/F curve setting
0 Linear V/F curve
:
1 square torque V/F curve
:0 46.
F1.21 Torque boost 0.0% (auto)
:0.1 30 .0%~ % 0 47.
F1.22 Torque bo ost cut-off 0.0% 50.0% (relative to motor
rated frequency)
~20.0% 48 .
F1.23 V/F slip compensation limit 0. 0 200. 0%
~100% 49 .
F1.24 Energy Conservation
Selection 0** 50 .
※
※
●
●
※
2:Reverse
5:Reverse Jogging
3:three-wire control
4:Forward Jogging
F2.03 454 .
F2.04 7 55.
●
●
S3 Terminal Function
Selection
S4 Terminal Function
Selection
6:Free run stop
7:Failure reset
8:External fault input
9:Frequency setting(UP)
10:Frequency setting(DOWN)
11:Frequency up/down setting
clear
16:PID control pause
17:Traverse pause at current
frequency
18:Traverse reset
19:ACCEL/DECEL forbid
20 25:Reserved
~
F2.06 13 57.
F2.07 Terminal control
mode
0 two-wire control 1:
1 two-wire control 2
:
2 three-wire control 1
:
3 three-wire control 2
:
0 58.
F2.08 UP/DOWN frequency
increment variable rate 0.01 50.00Hz/s
~0.50Hz/s 59.
F2.09 VI lower limit 0.00V 10.00V
~0.00V 60 .
F2.10 VI lower limit
corresponding setting -100.0% 100.0%~0.0% 61 .
F2.11 VI upper limit 0.00V 10.00V~10.00V 62.
F2.12 VI upper limit
corresponding setting -100.0% 100.0%
~100.0% 63 .
F2.13 VI input filtering time 0.00s 10.00s~0.10s 64.
F2.14 CI lower limit 0.00V 10.00V
~0.0 0V 65.
●
●
※
※
※
※
※
※
※
S6 Terminal F unction
Selection
F2.05 12 56 .
●
S5 Terminal F unction
Selection
12:Multi-Speed Terminal 1
13:Multi-Speed Terminal 2
14:Multi-Speed Terminal 3
15:ACCEL/DECEL Time selection
Function
Code Name Setting Range Modifi
cation
Serial
No
F2.15 CI lower limit
corresponding setting -100.0% 100.0%~0.0% 66.
F2.16 CIupper limit 0. 00V 10.00V
~10.00V 67.
※
※
Default
Value
Default
Value
0:No Operation
1:Energy Conservation
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB0 Series
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 17/54
- 2 7 - - 2 8 -
Function
Code Name Setting Range Modifi
cation
Serial
No
F2.22 FM outp ut
selection
Analog
1 Running frequency
:
0 Setting frequency
:
4 Running speed:
2 Output c urrent
:
3 Output voltage
:
5 Output power
:
6 Output torque:
7 VI input v a lue:
8 CI input value
:
9 10
~ :Reserved
0 73.
F2.23 AO Lowe r limit 0.0% 100.0%
~0.0% 74 .
F2.24 Lower limit corresponding
AO output 0.00V 10.00V
~0.00V 75.
F2.25 AO Upper limit 0.0% 100.0%~100.0% 76 .
Upper limit corresponding
AO output 0.00V 10.00V
~10.00V 77 .
F3.00 User password 0 6 55 35
~0 78.
F2.26
※
※
※
※
※
※
F3 Human Machine Interface Parameters
F2.17 CI upper limit
corresponding setting -100.0% 100.0%
~100.0% 68 .
F2.18 CI input filtering time 0. 00s 10.00s
~0.1 0s 69.
F2.19 Mo1output selection 0 NO output
:
4 Motor running forward:
5 Motor running reverse:
3 Fault output
:
2 FDT output
:
1 Frequency reached
:
6 Null speed operating
:
7 Upper limit frequency reached
:
8 Lower limit frequency reached
:
9 1 0 Res er ved
~ :
1 70.
F2.20 Mo2output selection 271 .
F2.21 Relay output selection 3 72.
※
※
※
※
※
Function
Code Name Setting Range Modifi
cation
Serial
No
F3.01 Reserved 79 .
F3.02 Reserved 80 .
F3.03 STOP function option
1 Keypad and terminal control
valid
:
0 Keypad control valid
:
2 Keypad and communication
control valid
:
3 All control modes valid
:
0 81.
F3.04 Keypad display option 0 82.
0 external keyboard preferential
ENB
:
1 Local and external keyboard
simultaneous display, only
external key-press is valid.
:
2 Local panel and external
keyboard simultaneous display,
only Local key-press is valid.
:
3 Localand externalkeyboard
simultaneous display, and all
key-presses are valid (both are
OR logical relation)
:
※
※
F3.05 255 83.
1
2
4
8
16
32
64
12 8
25 6
51 2
1024
2048
4096
8192
16384
※
Code
Displayed Message
0:Setting frequency
1:Running frequency
2:Output current
3:Output voltage
4:Running speed
5:Output power
6:Output torque
7:DC bus voltage
8:PID setpoint
9:PID feedback
10:Input terminal status
11:Output terminal status
12:VI value
13:CI value
14:Current segment of
multi-speed control
operationstatus display
parameter option
1
2
Setting frequency
DC bus voltage
255 84.F3.06 ※
Stop status display
parameter option
Default
Value
Default
Value
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 18/54
- 2 9 - - 3 0 -
Function
Code Name Setting Range Modifi
cation
Serial
No Function
Code Name Setting Range Modifi
cation
Serial
No
18:Communication fault(E018)
19:Current detect error(E015)
20:Motor self-learning error(E016)
21:EEPROM operation error
(E00F)
22:PID feedback disconnect error
(E02E)
23:Braking uniterror E01A( )
24:Reserved
F3.14 Operating frequency at
current fault 0.00Hz 92.
F3.15 Output amperage at
current fault 0.0A 93.
F3.16 Bus voltage at current fault 0.0V 94.
F3.17 Input terminal status at
current fault 095.
F3.18 Output terminal status at
current fault 096.
F4.00 ACCEL Time 2 0.1 3600.0s~10.0s 97.
F4.01 DECELTime 2 0.1 3600.0s
~10.0s 98.
F4.02 Joggingfrequency 0.00 F 0 .04~5.00Hz 99.
F4.03 JoggingACCEL time 0.1 3600.0s~10.0s 100.
F4.04 Jogging DECEL time 0.1 3600.0s~10.0s 101.
F4.05 Skip frequency 0.00 F 0 .04~0.00Hz 102.
F4.06 Skip frequency range 0 .00 F0.04~0.00Hz 103.
F4.07 Traverse frequency range 0.0 100.0%
relative to set frequency
~
( ) 0.0% 104.
F4.08 Kick frequency range 0.0 50.0%(relativeto traverse
frequency range)
~0.0% 105.
F4.09 Traverse frequency up
time 0.1 3600.0s~5.0s 106.
F4.10 Traverse frequency down
time 0.1 3600.0s~5.0s 107.
**
**
**
**
**
※
※
※
※
※
※
※
※
※
※
※
F4 Application Function Parameters
4
8
16
32
64
128
256
Input terminal status
Output terminal status
PID setpoint
PID feedback
VI value
CI value
Current segment of
multi-speed control
F4.11 Fault auto-reset times 0 3~0 108.
※
F4.12 Interval time setting of
automatic resetting fault 0.1 100.0s~1.0s 109.
※
Default
Value
Default
Value
Chapter 5 Function Parameters ListChapter 5 Function Parameters List
F3.07 85.
※
0-14 (0:invalid)
operation status display
p eferential optionr 0
16:IGBT module overheat fault
(E01E)
17:External fault(E017)
IGBT module temperature
F3.08 0 100.0~℃86.
F3.09 Software version 87.
F3.10 Accumulative operating
time 0 6 5535h~0 88.
F3.11 The fault before previous
fault type 89.
0 No fault:
1:IGBT U phase protection(E009)
4:Acceleration over-current(E004)
5:Deceleration over-current(E005)
6:Constant speed over-current
(E006)
7:Acceleration over-voltage(E002)
8:Deceleration over-voltage(E00A)
9:Constant speed over-voltage
(E003)
10:Bus under-voltage fault E001( )
11:Motor overload(E007)
12:Inverter o verload(E008)
13:Input side phase failure(E012)
14:Output side phase failure(E013)
15:(Diode module overheat fault
(E00E)
F3.12 Previous fault type 90.
F3.13 Current fault type 91.
**
**
**
**
**
**
2:IGBT V phase protection(E019)
3:IGBT W phase protection(E029)
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
DZB Series

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 19/54
- 3 1 - - 3 2 -
Function
Code Name Setting Range Modifi
cation
Serial
No
F4.13 FDT level detection value 0.00 F0.04~50.00Hz 110.
※
F4.16 Brake Threshold
Value Voltage
115.0 140.0%(standard DC bus
voltage) 380V
~130.0%
113.
115.0 140.0%(standard DC bus
voltage) 220V
~120.0%
F4.17 Speed display
ratio
0.1 999.9%
Speed=120 running
frequency F4.17/pole number
~
×
×
100.0% 114.
F4.18 PIDsetpoint
SourcesOp tion
0 Given by Keyboard(F4.19):
1 Given byAnalog Channel VI:
2 Given byAnalog Channel CI
:
3 Given by Remote
Communication
:
4 Multi-segsetpoint
:
0 115.
F4.19
PIDFeedback
SourcesOp tion
0.0% 100.0%~0.0% 116.
F4.20
Preset PID setpoint
0 VI Feedback:
1 CI Feedback:
2 VI+CI Feedback:
3 Communication feedback
:
0 117.
F4.21 PID Output Characteristics
Option
0 positive:
1 Pnegative:0 118.
F4.22 Proportional gain (Kp) 0.00 100.00~1.00 119.
F4.23 Integral time (Ti) 0.01 10.00s
~0.10s 120.
F4.24 Differential time (Td) 0.00 10.00s~0.00s 121.
F4.25 Sampling cycle time (T) 0.01 100.00s
~0.10s 122.
F4.26 PIDcontrol
discrepancy limit 0.0 100.0%~0.0% 123.
F4.27 Feedback disconnection
detecting value 0.0 100.0%~0.0% 124.
※
※
※
※
※
※
※
※
※
※
※
※
F4.14 FDTdelay detectionvalue 0.0 100.0%(FDT level)~5.0% 111.
F4.15
Frequencyr eaching
detection range 0.0 100.0%(maximum frequency)
~0.0% 112.
※
※
Function
Code Name Setting Range Modifi
cation
Serial
No
F4.31 Multi-Speed 2 -100.0 100.0%~0.0% 128.
F4.32 Multi-Speed 3 -100.0 100.0%~0.0% 129.
※
※
F4.33
Multi-Speed 4
-100.0 100.0%
~
0.0% 130.
F4.34 Multi-Speed 5 -100.0 100.0%~0.0% 131.
F4.35 Multi-Speed 6 -100.0 100.0%~0.0% 132.
F4.36 Multi-Speed 7 -100.0 100.0%~0.0% 133.
F5.00 Motor Overload
ProtectionOption
0 No protection:
1 normal motor:
2 Variable Frequency motor:
1 134.
F5.01 Motor Overload
ProtectionCurrent
20.0% 120.0%
(motor rated current)
~100.0% 135.
F5.02 Power-down Frequency
Drop Point
70.0 110.0%(standard bus
voltage)
~80.0% 136.
F5.03 Instantp ower-down
Frequency drop rate 0.00Hz F0.04~0.00Hz 137.
F5.04 Over-voltage
Stall Protection
0 prohibit:
1 a ll ow:0 138.
F5.05
Over-voltage Stall
ProtectionVoltage
110 150%(380V)~120%
139.
110 150%(220V)~115%
F5.06 Auto limit current level 100 200%~200% 140.
F5.07 Limit current frequency
drop rate 0.00 50.00Hz/s~0.00Hz/s 141.
F6.00 Communication Address 1 247,0 is the broadcast address~1142.
F6.01 Baud rate setting
0 1200BPS:
1 2400BPS:
2 4800BPS:
3 9600BPS:
4 19200BPS:
5 38400BPS:
3 143.
※
※
※
※
※
※
※
●
※
※
※
※
※
※
F5 Protection Parameters
F6 Communication Parameters
F4.28 Feedback disconnection
detecting time 0.0 3600.0s~1.0s 125.
F4.29 Multi-Speed 0 -100.0 100.0%~0.0% 126.
F4.30 Multi-Speed 1 -100.0 100.0%~0.0% 127.
※
※
※2:Even check O,8,1 f orR TU
( )
F6.02 Data pattern 144.
0:No check N,8,1 for RTU( )
1:Oddcheck E,8,1 for RTU( ) ※
0
Default
Value
Default
Value

5/14/2018 Fuling Inverter User Manual - slidepdf.com
http://slidepdf.com/reader/full/fuling-inverter-user-manual 20/54
Other manuals for DZB200 Series
1
This manual suits for next models
29
Table of contents
Other Fuling Inverter Inverter manuals
Popular Inverter manuals by other brands

Steca
Steca coolcept Installation and operating instructions

GNB
GNB ENERGYSTORE Series Installation, operation and maintenance

Kaco
Kaco blueplanet 50.0 TL3 S operating instructions

Lenze
Lenze EZAMBHXX028 Mounting instructions

Mastervolt
Mastervolt Whisper 6 installation manual

Agilent Technologies
Agilent Technologies 33120A Service guide