3. Operation on Remote Alarm Panel (RAP)
To silence the alarm, press the ACK button. When the ERROR LED on the Remote Alarm
Panel is on, identify the error by checking the status LEDs on the PDU in the DCU, referring to
the operator’s manual. The buttons on the remote alarm panel work as described in the figure
below.
Remote Alarm Panel (RAP)
4. If an Incident Occurs
1. Press the SAVE button (long press) on the RAP until the SAVE LED blinks.
After completing the save process, the buzzer on the RAP sounds and the SAVE LED
stops blinking and lights.At this time, although recording to the HD is stopped in order to
protect data in HD, recording at the DRU continues.
Note: Do not press the SAVE button except when an incident occurs.
2. Bring the HD with you when leaving the vessel if possible. Do not turn off the power.
1) Open the DCU with the key.
2) Open the front panel of the Data Processor Unit with the key (see previous page).
3) Turn the lever of HD outward and then turn the key fully counterclockwise.
4) Pull the lever to take out the HD.
Note: Rerecording to the HD is prevented in order to protect data. Follow the procedure below
to replace it with a new HD if necessary.
1. Open the DCU with the key and turn off the three breaker switches.
2. Open the front panel of the Data Processor Unit with the key.
3. Turn the lever of HD outward and then turn the key fully counterclockwise.
4. Pull the lever to take out the HD and replace it with a new one.
5. Turn the key for HD fully clockwise.
6. Close the front panel of the Data Processor Unit with the key.
7. Turn on the three breaker switches. Confirm that the SAVE LED of RAP goes off.
8. Close the DCU with the key.
Note: The backup HD may only be replaced in the following situations:
1) When the equipment can be powered off (stopped recording). See previous page.
2) When completing the save process after an incident occurs.
Dimmer Buzzer
Buttons from left
SAVE (w/ protective cover):
Stops recording onto HD
only when an incident
occurs.