manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Furuno
  6. •
  7. Touch Terminal
  8. •
  9. Furuno DSC-6 User manual

Furuno DSC-6 User manual

Models DSC-6/6A
Catalogue No. W-3219d
MF/HF DSC TERMINAL
●Distress and safety communications
●Fast and efficient routine communications
●24-character x 2-line LCD display backlit for
nighttime use
●File editing capability for readiness in
emergency
●Automatic entry of own ship position (nav
option) with manual override
●Scanning of DSC frequencies for distress
and general calls on MF/HF
●Semi-automatic/Automatic telephone service
●Options:
Printer PP-500/510, Distress Message
controller DMC-5 for centralized
control/monitoring distress alarms
The Digital Selective Calling (DSC) system is one of the
essential elements of the GMDSS, the automated digital
communication system developed by the International
Maritime Organisation (IMO) to enhance navigational
safety. The DSC system can also be used to quickly
and efficiently establish routine communications with
other ships and coast stations that are DSC equipped.
The DSC-6/6A both consist of a combined encoder and
decoder for generating and receiving digital selective
calls. When used in conjunction with a FURUNO MF/HF
transmitter/receiver they provide full automatic control of
transmit and receive frequency, class of emission, and
other parameters as entered from the front panel or
contained in the telecommand information in an
incoming call. They also allow scanning of distress or
routine DSC frequencies via an appropriate FURUNO
receiver.
In an emergency the DSC-6/6A transmits a distress alert
via the radio equipment five seconds after pressing the
[DISTRESS] button. When the DSC Watch Receiver
AA-50 is connected, the DSC-6 processes the
messages received on the MF/HF DSC distress and
safety frequencies.
The DSC-6A incorporates an independent receiver
which keeps a continuous watch on MF DSC frequency
2187.5 kHz.
R
The future today with FURUNO's electronics technology.
FURUNO ELECTRIC CO., LTD.
9-52 Ashihara-cho, Nishinomiya City, Japan Telephone: +81 (0)798 65-2111
Telefax: +81 (0)798 65-4200, 66-4622, 66-4623
R
TRADE MARK REGISTERED
MARCA REGISTRADA
GENERAL CHARACTERISTICS
1. Rules and Regulations
CCIR Rec. 493 (Class A), 541
IMO Res. A609 (15), CEPT TR/34-01
2. Distress Call and Message
Distress Call and Message (RR3112: Format specifier
(distress), Self-ID, Nature of distress, Distress coordinates,
Time, Telecommand, EOS, ECC)
3. Class of Emission
DSC: F1B/J2B (J2B w/FS-1562)
Voice:J3E, H3E (2182 kHz)
TTY: F1B/J2B (J2B w/FS-1562)
4. Manual Setting or Scan of Distress Frequencies
MF/HF DSC:
2187.5, 4207.5, 6312, 8414.5, 12577, 16804.5 kHz
Corresponding MF/HF NBDP (not scanned):
2174.5, 4177.5, 6268, 8376.5, 12520, 16695 kHz
TP: 2182, 4125, 6215, 8291, 12290, 16420 kHz
5. Message Storage
Receive:
50 distress messages max. plus 50 non-distress messages
Transmit:
50 non-distress messages plus 99 files containing station ID,
telephone no., frequency, etc.
6. Nav Data
IEC61162
7. Alarms
Aural and visual on receipt of distress, urgency or general
calls
8. Display
24 characters x 2 lines
Character composition: 5 x 7 dots
LCD with adjustable backlighting
9. Modulator and Demodulator
Level: -30 dBm to +10 dBm at 600 ohms, balanced
Frequency: Mark 1615 Hz, Space 1785 Hz, 100 baud
Stability: ±0.5 Hz
RECEIVER CHARACTERISTICS OF DSC-6A
Receive Frequency: 2187.5 kHz
Sensitivity: Error rate 1 % at 0 dBµV
POWER SUPPLY
10.8 - 40.0 VDC, 15 W
115/230 VAC thru AC/DC changeover supply
EQUIPMENT LIST
Standard
1. DSC terminal
2. Installation materials and spare parts
Optional
1. Mounting bracket
2. Printer PP-500
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
SPECIFICATIONS OF DSC-6/6A
99043N Printed in Japan
24 VDC
VCTF-1.25
x 2C, 3 m
Operator’s room
Distress
message
controller
DMC-5
Centralized control/monitoring
Captain’s room
CO-SPEVV-SB-C
0.2 x 2 P, 30 m max.
Alarms
DSC-6/6A standard system
PRINTER
PP-500/510
115 or 230 VAC 24 VDC
Position data
Distress alarms
ALLWAVE RECEIVER
RV-107
DPYC-1.25
57FE-338-205W, 5 m
Setting telecommand,
working freq., etc.
CO-SPEVV-SB-C,
0.2 x 2P, 30 m max
(2 ports for MF/HF
DSC and VHF DSC)
NAV
NBDP Terminal
DP-5/6
MF/HF DSC
RECEIVER
AA-50
Option
Setting telecommand,
working freq., etc.
DSC distress
and safety
(continuous watch)
DSC signal,
telephony,
telex
DSC ship business and routine
(scanning watch)
DSC signal,
telephony,
telex
DSC distress
and safety
(continuous watch)
DSC ship business and routine
(scanning watch)
NAVTEX Receiver NX-500
2182 Watch receiverAA-45B
EGC Receiver EGC-5
DSC-6/6A
FS-1562
For DSC-6A
DPYC-1.25
(For PP-500) (For PP-510)
FS-1562
NBDP Terminal
DP-5/6
MF/HF DSC
RECEIVER
AA-50
DSC-6/6A
For DSC-6A
299 11.8"
258 10.2"
143 5.6"
(95 3.7") (95 3.7") 6 -˘7.5
254.1 10.0"
127 5.0"
89 3.5"
(89 3.5")
Weight: 3.5 kg
FURUNO U.S.A., INC.
Camas, Washington, U.S.A.
Phone: +1 360-834-9300 Telefax: +1 360-834-9400
FURUNO (UK) LIMITED
Denmead, Hampshire, U.K.
Phone: +44 1705-230303 Telefax: +44 1705-230101
FURUNO FRANCE S.A.
Bordeaux-Mérignac, France
Phone: +33 5 56 13 48 00 Telefax: +33 5 56 13 48 01
FURUNO ESPANA S.A.
Madrid, Spain
Phone: +34 91-725-90-88 Telefax: +34 91-725-98-97
FURUNO DANMARK AS
Hvidovre, Denmark
Phone: +45 36 77 45 00 Telefax: +45 36 77 45 01
FURUNO NORGE A/S
Ålesund, Norway
Phone: +47 70 102950 Telefax: +47 70 127021
FURUNO SVERIGE AB
Västra Frölunda, Sweden
Phone: +46 31-7098940 Telefax: +46 31-497093
FURUNO SUOMI OY
Helsinki, Finland
Phone: +358 9 3417570 Telefax: +358 9 3415716

Other manuals for DSC-6

2

This manual suits for next models

2

Other Furuno Touch Terminal manuals

Furuno FELCOM 19 User manual

Furuno

Furuno FELCOM 19 User manual

Furuno DP-6 User manual

Furuno

Furuno DP-6 User manual

Furuno DP-6 User manual

Furuno

Furuno DP-6 User manual

Furuno DP-6 Manual

Furuno

Furuno DP-6 Manual

Furuno FV-110GX User manual

Furuno

Furuno FV-110GX User manual

Furuno FELCOM19 Inmarsat Mini-C MES User manual

Furuno

Furuno FELCOM19 Inmarsat Mini-C MES User manual

Furuno VHF DSC Terminal DSC-8V/8VP User manual

Furuno

Furuno VHF DSC Terminal DSC-8V/8VP User manual

Popular Touch Terminal manuals by other brands

Ingenico group swipen Move 5000 quick start guide

Ingenico group

Ingenico group swipen Move 5000 quick start guide

Protech Systems PA-3122 user manual

Protech Systems

Protech Systems PA-3122 user manual

Thrane&Thrane BGAN Thrane&Thrane Explorer 700 Getting started guide

Thrane&Thrane

Thrane&Thrane BGAN Thrane&Thrane Explorer 700 Getting started guide

Aastra 6753 user guide

Aastra

Aastra 6753 user guide

Orderman Sol+ operating instructions

Orderman

Orderman Sol+ operating instructions

aqprox! appTPV03 user guide

aqprox!

aqprox! appTPV03 user guide

SSD Drives IBT Series Product description

SSD Drives

SSD Drives IBT Series Product description

XAC xCE-200T.3GxCE-E200T.3G installation guide

XAC

XAC xCE-200T.3GxCE-E200T.3G installation guide

ABB SPAC 315 C User manual and technical description

ABB

ABB SPAC 315 C User manual and technical description

VeriFone IX90 M440 installation guide

VeriFone

VeriFone IX90 M440 installation guide

Akuvox A01 Admin guide

Akuvox

Akuvox A01 Admin guide

Unitech TASHI MT380-A7WE0G user manual

Unitech

Unitech TASHI MT380-A7WE0G user manual

IBM 4693 Installation and operation guide

IBM

IBM 4693 Installation and operation guide

Festo CPX Series manual

Festo

Festo CPX Series manual

ZKTeco US922 Series user guide

ZKTeco

ZKTeco US922 Series user guide

VeriFone Omni 3600 installation guide

VeriFone

VeriFone Omni 3600 installation guide

Wintec SelfPOS86 quick start guide

Wintec

Wintec SelfPOS86 quick start guide

SAND IPS420 user manual

SAND

SAND IPS420 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.