Gantner GAT Info 6100 User manual

Function description
The GAT Info 6100 is used to indicate visitor information for a short period
on the display by holding the data carrier over the round scan field. Visitor
information can be locker number in use, credit balance, visit duration etc.
Further functions:
•User guidance via monochrome display (LCD), 4-segment LED display,
illuminated round scan field and beeper
•Secure data transmission between reader and data carrier
•RFID frequency 13.56 MHz
•Reading of LEGIC®, MIFARE®standard and ISO 15693 data carriers
(depending on device type)
•Opening of housing only possible with special tool
•Plug & Play installation
GAT Info 6100
Information Terminal
Application
The GAT Info 6100 is a stylish terminal for displaying visitor information
in leisure facilities such as swimming pools, spas and gyms. Identification
at the terminal is by contact-free RFID data carrier (Radio Frequency
Identification).
The Information Terminal is operated by four function keys. Information
display for user guidance is realised via a graphical monochrome display
(LCD). The different versions (see order information) give technological
flexibility.
Description PartNo.
GAT Info 6100 B
Information terminal for readout of locker number, balance
etc. for LEGIC®data carriers, with monochrome display
(LCD)
776790
GAT Info 6100 F
Information terminal for readout of locker number, balance
etc. for MIFARE®data carriers, with monochrome display
(LCD)
776891
GAT Info 6100 ISO
Information terminal for readout of locker number, balance
etc. for ISO 15693 data carriers, with monochrome
display (LCD)
653380
1
www.gantner.com
Order information
Description PartNo.
GAT Reader WK
Tool to open the reader housing
581683
Accessories
Valid as from February 15
th
2016 • Technical data subject to modifications without notice!
DB_GAT-INFO6100--EN_11.indd • PartNo.: 860380

Nominal voltage: 12/24 VDC (SELV - safety extra-low
voltage)
Permitted input voltage: 10 to 28 VDC
Input current: 300 mA
Data storage: Internal EEPROM memory for
configuring and booking memory,
data preservation min. 10 years
Internal clock: Data preservation approx. 12 h
(Gold-Cap)
Reader type: See order information
Frequency reading field: 13.56 MHz
Control elements: - 4 function keys
- RFID reader
Display elements: - Full graphics monochrome display
(LCD) with white LED background
lighting, resolution 128 x 64 pixels,
visible area 50 x 25 mm
- RFID reader (illuminated)
- Acoustic signal
- Multi-coloure, 4-segment LED
display (green/red/yellow)
2www.gantner.com
Technical data
Typical application
GAT Info 6100
Power supply
Network
i
Dimensions
1. 4-segment LED display
2. Monochrome display (LCD)
3. Function keys
4. Illuminated, round scan field
5. Device back part
6. Device front part
93 mm (3.66´´) 33 mm (1.3´´)
24 mm (0.94´´)
107 mm (4.2´´)
2
3
4
56
1
Valid as from February 15
th
2016 • Technical data subject to modifications without notice!
DB_GAT-INFO6100--EN_11.indd • PartNo.: 860380
Host interface: Ethernet 10/100 Mbit/s
Connection terminals: 0.5 to 1.5 mm2
Housing material: - Front part: plastic PMMA
- Back part: plastic PC-ABS
Dimensions: 93 x 107 x 33 mm
(3.66” x 4.21” x 1.30”)
Permitted ambient temperature: -10 to +55°C (+14 °F to +131 °F)
Storage temperature: -20 to +70°C (-4 °F to +158 °F)
Relative humidity: 20 to 80%, non-condensing
Protection type: IP 54
Protection class: III
Weight: 200 g (7.05 oz)
Environment class: II (conditions in indoor areas)

3
www.gantner.com
Valid as from February 15
th
2016 • Technical data subject to modifications without notice!
DB_GAT-INFO6100--EN_11.indd • PartNo.: 860380
Mounting and installation instructions
The back part of the device attaches to a flat surface (e.g., concrete wall)
using screws. When attaching to an uneven surface the device back part
must not be distorted as this prevents the correct connection of the device
front part. Recommended mounting height = 1.3 m (top edge of device).
Use the drilling template that is attached to the device.
Mounting the device front part
Once the connection cables are terminated, the device back part and front
part are connected together via a connection cable (delivered already
connected in the front part) and the two parts are fixed together.
1. 2.
Notes:
1. Check the socket in the device back part (circled in figure 1). Any dirt,
dust and moisture must be removed to ensure correct operation. Do
not use any aggressive detergent and take care not to damage the
socket contacts if cleaning is required.
Attention: Only clean the device in powerless state.
2. Plug in the connection cable into the socket on the device back part
(consider alignment) and clip the top of the device front part into the
device back part.
Wall mounting
Cabling can be flush mounted (1) or surface mounted (2).
When surface mounting the cabling, ensure they can still be inserted once
the device back part has been mounted. Otherwise run the cables through
the cable lead-ins prior to securing.
1. Flush-mounted cable
2. Surface-mounted cable
3. Back box
4. Device back part
5. Cable conduit for surface cable connection
3. 4.
3. Swing down the device front part until it clicks into place.
4. The device can only be opened using the supplied special tool! With
the tool, the two catches on the bottom of the device are released in
succession.
69 mm (2.72´´)
13 mm (0.51´´)
18.5 mm (0.73´´)
28.5 mm (1.12´´) 20 mm
(0.79´´)
71 mm (2.8´´)
60 mm (2.36´´)
2
3
4
5
1

4www.gantner.com
Electrical connections
TCP/IP with external power supply
GAT Info 6100
31
2
RX +
TX -
TX +
GND
NO 1
C 1
IN1 -
IN1 +
RX -
VIN +
TCP/IP
Power supply unit
e.g. GAT Power Supply SP014/1
VOut+
GND
A
B
Mains power
Safety instructions
- This device must be installed by qualified personnel only.
- The applicable safety and accident prevention regulations
must be observed.
- Safety devices must not be removed.
- Please observe the technical data of the device specified
on the data sheet.
- The device must be disconnected from the power supply
prior to installation, assembling or dismantling.
Valid as from February 15
th
2016 • Technical data subject to modifications without notice!
DB_GAT-INFO6100--EN_11.indd • PartNo.: 860380
Network
Ethernet connection (1) via screw terminals.
Power supply
DC supply (see technical data), e.g. via GANTNER GAT Power Supply
SP014/1 (2). The power input is protected against reverse polarity.
Recommended cables:
Ethernet: min. CAT 5 (STP) for 100 MBit
Wiring standard
Ethernet 10/100 MBit
Connection to the device front part
Plug the connection cable into the socket on the device back part
(consider alignment).
Attention: The socket (3) for the connection cable between the device
back part and the device front part must be clean to ensure
correct operation.
Relay output
No function.
Optocoupler input
No function.
568A 568B
TX + green/white orange/white
TX - green orange
RX + orange/white green/white
RX - orange green
Applicable for the following devices:
- GAT Info 6100 F
FCC NOTICE (Class B)
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, included interference that
may cause undesired operation.
Note: This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instructions, may cause harmful interference to radio communications. However, there
is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the interference by
one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that of which the receiver
is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Warning Statement
[Any] changes or modifications not expressly approved by the party responsible for compliance
could void the user‘s authority to operate the equipment.
GANTNER is committed to meeting or exceeding the requirements of the
RoHS directive (2011/65/EU). The RoHS directive requires that manufacturers
eliminate or minimize the use of lead, mercury, hexavalent chro-mium, cadmium,
polybrominated biphenyls and polybrominated diphenyl ethers in electrical and
electronic equipment sold in the EU after July 1, 2006.
This product is herewith confirmed to comply with the requirements set out
in the Council Directives on the Approximation of the laws of the Member
Statesrelating to Electromagnetic Compatibility Directive 2004/108/EG.
This product is in conformity with the following EC directives, including all
applicable amendments:
- 1999/5/EC (R&TTE directive)
- 2004/40/EC (Limitation of human exposure to electromagnetic fields)
- 2011/65/EU (Restriction of the use of certain hazardous substances in
electrical and electronic equipment)
The WEEE symbol on GANTNER products and their packaging indicates that the
corresponding material must not be disposed of with normal household waste. Instead,
such marked waste equipment must be disposed of by a designated electronic waste
recycling facility. Separating and recycling this waste equipment at the time of disposal
will help to conserve natural resources and ensure that it is recycled in a manner that
protects human health and the environment. For more information on recycling an item
marked with the WEEE symbol, please contact your local city office or your household
waste disposal operation.
RoHS
COMPLIANT
Table of contents
Other Gantner Touch Terminal manuals
Popular Touch Terminal manuals by other brands

Westpac
Westpac EFTPOS Now Quick reference guide

Custom Audio Electronics
Custom Audio Electronics PT-3000 manual

Symbol
Symbol PDT 8056 instruction manual

Hypercom
Hypercom ICE 4000 Hardware and installation manual

Elo TouchSystems
Elo TouchSystems 15A2 for wireless card Quick installation guide for memory 512mb/1gb ram

TOPSCCC
TOPSCCC EX-96085 user manual