Contents
Using LCD Keypads
Introduction................................................................... 2
User Code Types.......................................................... 2
Setting The System ...................................................... 3
Unsetting The System .................................................. 3
Part Setting The System............................................... 4
Removing Zones........................................................... 5
Testing The System...................................................... 6
Viewing The Event Log................................................. 7
Changing The Chime Status......................................... 8
Programming User Codes ............................................ 9
Programming Time & Date ........................................... 10
User Initiating Remote Access ..................................... 11
Resetting After An Alarm .............................................. 12
Resetting After Mains Failure ....................................... 13
Using LED Keypads.................................................... 13
Setting The System ...................................................... 13
Unsetting The System .................................................. 14
Part Setting The System............................................... 14
Area Setting.................................................................. 15
Removing Zones........................................................... 23
Testing The System...................................................... 16
Viewing The Event Log................................................. 17
Changing The Chime Status......................................... 18
Programming User Codes ............................................ 18
User Initiating Remote Access...................................... 19
Resetting After An Alarm .............................................. 20
Resetting After Mains Failure ....................................... 20
LED Display Glossary................................................... 21
System Attributes.......................................................... 23
Service Record ............................................................. 23
User Chart .................................................................... 24
ACE Instructions........................................................... 25
Programming ACE Keyfobs onto your System............. 26
Page 1
GARDTEC
590/591
User Manual
PR5075U.qxd 19/06/00 10:59 Page 1

Page 2
GARDTEC
590/591
User Manual
Introduction
Two types of display variation are available, LCD giving two rows of 16 character
English text and may be used on the Gardtec 591 and LED giving two 7 segment LED
digits that may be used on the Gardtec 590 & 591.
Please take time to familiarise yourself with the type of equipment fitted to your
premises as it will prove invaluable whilst using this manual.
User Code Types
Four types of User Codes are available on the Gardtec 590/591
,
each user code type
allows for different levels of access. In total 7 User codes may be programmed by a
Master Level User Code.
User number 1 will always be a Master Level User but the remaining 6 User Codes
may be programmed (by a Master Code) to the required level of access. These may be
changed at any time via a Master level code
The User Code levels available and the functions available for the levels are:-
1 = Set Only Only Allows for the setting of the system.
2 = Main User Allows Setting, Part Setting, Zone Remove (if programmed
by engineer), System Test, Unsetting, Reset after Alarm (if
programmed by engineer).
3 = User Allows Setting, Part Setting, Reset after Alarm (if
programmed by engineer), Unsetting.
4 = Master Allows Setting, Unsetting, Zone Remove (if programmed by
(User 1 always Master) engineer), Test System, View Log, Chime On/Off, User
Codes, Set Time/Date, Reset After Alarm (if programmed
by engineer), Unsetting.
PR5075U.qxd 19/06/00 10:59 Page 2

Page 3
GARDTEC
590/591
User Manual
Setting The System
This section is for systems fitted with LCD keypads for
LED keypads please refer to page 13
1) With the display showing:-
2) Enter the User code (followed by YES if
Master or Main type code has been used).
The display will show:-
and a continuous exit tone will sound
3) Exit the premises via the authorised exit
route (the exit tone will change if any detectors
are violated during exit)
4) Once the premises are secure listen that the exit
tone returns to the continuous tone.
5) Wait until the exit tone finishes before leaving.
Unsetting The System
1) Enter the premises via the authorised entry route
(the broken entry tone will sound),
proceed to the keypad.
2) At the keypad enter a valid code, the display
will show:-
3) The system is now unset.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
EXIT Now !
All Zones ON 15
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
PR5075U.qxd 19/06/00 10:59 Page 3

Page 4
GARDTEC
590/591
User Manual
Part Setting The System
(using Master & Main type codes)
1) With the display showing:-
2) Enter a Master or Main type code, the
display will show for example:-
3) Press 1, 2 or 3 (for Part 1, 2 or 3), the
display will show for example:-
4) The exit tone may or may not be heard
dependant on the system settings.
5) Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop or a single
beep will be emitted (dependant on system
settings).
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
EXIT Now!
Part 1 15
PR5075U.qxd 19/06/00 10:59 Page 4

Page 5
GARDTEC
590/591
User Manual
Removing Zones
(Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code.
1) With the display showing:-
2) Enter a Master or Main level code,
the display will show:-
3) Press NO, the display will show:-
4) Press YES, the display will show:-
5) Enter the zone number you wish to
remove followed by YES (pressing
NO will 'un-remove' a zone), the
display will show:-
6) Repeat step 5 until you have removed all
the required zones.
7) Press 0 to escape, the display will show:-
8) Press YES, the continuous exit tone will
sound.
9) Exit the premises via the authorised
exit route ( the exit tone will change as detectors
are violated). When the premises are secure
listen that the exit tone returns to the continuous
tone. Wait until the exit tone finishes before leaving.
Note: Zone remove is only effective for the one set.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
Set ?
Do you want to . .
REMOVE Zones ?
Enter Zone No. - -
then + YES or - NO
Enter Zone No. - -
then + YES or - NO
PR5075U.qxd 19/06/00 10:59 Page 5

Page 6
GARDTEC
590/591
User Manual
Testing The System
(Master & Main codes only)
1) With the display showing:-
2) Enter a Master or Main level code,
the display will show:-
(User Names on 816 & 840 Only)
3) Press NO, the display will show:-
4) Press NO, the display will show:-
5) Press YES, the display will show:-
for 3 seconds
Then for example:-
6) Pressing 1 will enter zone Status mode (All zones will show on the display
and will be deleted as each zone is triggered). Press 0 to escape.
Pressing 6 will silence the internal sounder,
Pressing 4 will toggle the Strobe On/Off,
Pressing 9 will toggle the Bell On/Off
7) Whilst in Test mode any zones violated
will sound the internal sounder (if it has
not been silenced) and show on the
display.
8) When you have finished testing the
system press 0 twice, the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
REMOVE Zones ?
Do you want to . .
TEST the System ?
1=Status 4 = Strobe
6 = Sounder 9 = Bell
< All Zones OK >
TESTING . . .
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
PR5075U.qxd 19/06/00 10:59 Page 6

Page 7
GARDTEC
590/591
User Manual
Viewing The Event Log
(Master code only)
1) With the display showing:-
2) Enter a Master Code, the display
will show for example:-
3) Press NO three times, the display
will show:-
4) Press YES, the display will show:-
for 3 seconds
Then, for example:-
5) This is the most recent event in the log.
Whilst viewing the Log,
Pressing NO will move back to the previous event.
Pressing YES will move forward to the next event.
Pressing 7 will take you back to the last event of
the previous day.
Pressing 9 will take you forward to the first event of
the next day.
6) When you have finished viewing the Log press 0 twice
the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
View the LOG ?
While Viewing . . .
1 = Printer On / Off
Read Log
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
PR5075U.qxd 19/06/00 10:59 Page 7

Page 8
GARDTEC
590/591
User Manual
Changing The Chime Status
(Master code only)
The Chime zones will have previously been programmed by the installation company.
A Master level code may change the status of the Chime between On and Off. To do
so proceed as follows:-
1) With the display showing:-
2) Enter a Master Code, the display will
show for example:-
3) Press NO four times, the display will show:-
4) Press YES the display will show for example:-
Or:-
5) Press NO to change the status of the Chime,
then press YES, the display will show:-
6) Press 0 to escape, the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . ?
Do you want to . .
Change Chime ?
Chime is Off ok ?
Chime is On ok ?
Do you want to . .
Change Chime ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
PR5075U.qxd 19/06/00 10:59 Page 8

Page 9
GARDTEC
590/591
User Manual
Programming User Codes
(Master code only)
1) With the display showing:-
2) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
3) Press NO five times, the display will show:-
4) Press YES, the display will show:-
(1 - 7) displayed on 800 & 816
5) Enter the user number (1 to 7) that you
wish to program followed by YES, the
display will show:-
6) Enter the code you require (codes may be 4,
5 or 6 digits) followed by YES.
(Entering 000000 will delete an existing code)
Note: If the code already exists or is a duress of
another code an error will be shown,
choose another code and return to step 6
7) The display will show:-
(not if user 1 is being programmed).
The display will scroll showing the code
types available (see user types or display).
8) Enter the required type followed by YES,
the display will show:-
9) If you wish to program other User Codes
return to step 4
Or
Press 0 to return to:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
Prog. USER CODES ?
Enter User No. - -
(1- 7) Then YES
Now Enter Code . .
- - - - - - Then YES
Choose Type . . -
0 = xxxxxx 1 = xxxxxx
Do you want to . .
Prog. USER CODES ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
PR5075U.qxd 19/06/00 10:59 Page 9

Page 10
GARDTEC
590/591
User Manual
Programming Time & Date
1) With the display showing:-
2) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
3) Press NO six times, the display will show:-
4) Press YES the display will show:-
5) Enter the Day/Month (ie. 0706 for 7th June)
followed by YES. The display will show:-
6) Enter the time using 24Hr Clock (ie. 23:30 for
11:30pm) followed by YES the display will show:-
7) Press 0 the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
Set DATE / TIME ?
Enter Day / Month
-- -- / -- -- Then YES
Enter Hrs / Mins
-- -- : -- -- Then YES
Do you want to . .
Set DATE / TIME ?
< < < < UN-SET > > > >
07 Jun 23: 30: 02
PR5075U.qxd 19/06/00 10:59 Page 10

Page 11
GARDTEC
590/591
User Manual
User Initiating Remote Access (Optional)
Access Remote allows your installation company to examine your system and re-
program system settings as you need the changes without the need for an engineer to
visit your premises.
If your system has remote communications fitted your installation company may have
programmed the system so that you initialise the Access Remote call (usually on lines
with incoming calls barred).
To initiate the Remote Call follow the instructions below.
1) Negotiate with your installation company when you should
initiate the Remote Call.
2) With the display showing:-
3) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
4) Press NO seven times, the display will show:-
5) Press YES the display will show:-
Until Dialling commences
Then:-
Until Connection
Then:-
6) When your installation company has finished
the display will show:-
Note: In the event of any errors the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set ?
Do you want to . .
Access Remote ?
Please WAIT
Please WAIT
Dialling
Please WAIT
Connect
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
! ! ! ! ERROR ! ! ! !
Try Again . . . .
PR5075U.qxd 19/06/00 10:59 Page 11

Page 12
GARDTEC
590/591
User Manual
Resetting After an Alarm
Your installation company will have programmed the reset modes for your system so
that it complies to your insurance company and legislation requirements.
Your installation company will have informed you as to the type of reset that your
system is set for.
Before attempting to reset your system ensure that the system is Un-set.
1) If the system is programmed for any code reset
enter a user (followed by YES if Master or Main
code is used), the exit tone will sound and the
display will show for example:-
2) Enter the code again to abort the setting
3) The system is now reset
Or
If a higher level of code is required one of
the following displays will be shown:-
Use a Master code to reset the system.
Or:-
Call the installation company
Or:-
Call the installation company and quote
the number given
Or:-
Can't Set Use
Master Code
Can't Set Use
ENGNR Code
Can't Set Use
ENG +Anti Code 1234
Can't Set Use
Anti Code 1234
EXIT Now !
All Zones ON 15
PR5075U.qxd 19/06/00 10:59 Page 12

Page 13
GARDTEC
590/591
User Manual
4) To reset the system with an anti-Code, contact
the central station or engineer (as instructed by
the installation company) and quote the source
given by the display.
5) The central station or engineer will give a return
Anti-Code ( this may contain the YES & NO keys)
for example 5, YES, 2, 4.
6) Enter this Anti-Code into the keypad
7) The system is now reset.
Resetting After Mains Failure
After a mains failure the user will have to enter his/her code twice in order to operate
the system.
Using LED Keypads
This section is dedicated to using LED keypads (Twin Seven Segment).
Setting The System
1) With the display showing U N
2) Enter the User Code (followed by YES if Master or Main type code has been
used).
3) The display will show E = and the exit tone will sound. Exit the premises via
the authorised exit route (the exit tone will change if any detectors are
violated during exit).
4) Once the premises are secure listen that the exit tone returns to the
continuous tone.
5) Wait until the exit tone finishes before leaving.
PR5075U.qxd 19/06/00 10:59 Page 13

Page 14
GARDTEC
800 Series
Unsetting The System
1) Enter the premises via the authorised entry route (the broken entry tone will
sound).
2) Proceed to the keypad, enter a valid user code, the display will show U N
3) The system is now Unset.
Part Setting The System
(using Master & Main type codes)
1) With the display showing U N Enter a Master or Main type code
2) The display will show S E (flashing). Press 1, 2 or 3 (for Part 1, 2 or 3) the
display will show the Eand:-
The two bottom bars if Part 1 has been selected
The top and bottom bars if Part 2 has been selected
The bottom bar only if Part 3 has been selected.
3) The exit tone may or may not be heard dependant on the system settings.
4) Exit the premises or retire to an unprotected part of the system. At the end
of the exit time either the exit tone will stop or a single beep will be emitted
(dependant on system settings).
GARDTEC
590/591
PR5075U.qxd 19/06/00 10:59 Page 14

Page 15
User Manual
Removing Zones
(Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code.
1) With the display showing U N Enter a Master or Main level code.
2) The display will show S E (flashing), press NO.
3) The Display will show r E (flashing), press YES.
4) The display will show r -
5) Enter the zone number you wish to remove followed by YES.
6) The display will show r -
7) If you wish to remove other zones return to step 5
Or
To escape press 0 the display will show S E (flashing).
8) Press YES to start setting the system.
9) Exit the premises or retire to an unprotected part of the system. At the end
of the exit time the exit tone will stop provided the system was clear.
Note: Zone remove is only effective for the one set.
GARDTEC
590/591
PR5075U.qxd 19/06/00 10:59 Page 15

Page 16
GARDTEC
590/591
User Manual
Testing The System
(Master & Main codes only)
1) With the display showing U N
2) Enter a Master or Main level code, the display will show S E (flashing).
3) Press NO twice, the display will show t E (flashing).
4) Press YES, the display will show t A press YES if you wish to test all areas
(or press NO until the area you wish to test is displayed then press YES)
5) The display will show t E (if all zones are clear).
6) Whilst in test mode:-
Pressing 6 will silence the internal sounders
Pressing 4 will toggle the strobe On / Off
Pressing 9 will toggle the Bells On / Off
7) When you have finished testing the system press 0 twice to return to the
Unset condition.
PR5075U.qxd 19/06/00 10:59 Page 16

Page 17
GARDTEC
590/591
User Manual
Viewing The Event Log (Master code only)
1) With the display showing U N enter a Master code.
2) The display will show S E (flashing), press NO three times.
3) The display will show L O (flashing).
4) Press YES, the display may show for example A L this is the most recent
event.
5) Whilst viewing the Log :-
Pressing NO will move back to the previous event.
Pressing YES will move forwards to the next event.
Pressing 7 will take you back to the first event of the previous day.
Pressing 9 will take you forwards to the first event of the next day.
Pressing 3 will display the Date / Time in the format
Day of month (two digits)
Month (two digits)
Hour (two digits)
Seconds (two digits)
7) When you have finished viewing the Log press 0 twice to return to the Unset
condition.
Note: A complete list of possible LED displays is given in the section LED
Display Glossary.
PR5075U.qxd 19/06/00 10:59 Page 17

Page 18
GARDTEC
590/591
User Manual
Changing The Chime Status
(Master code only)
The Chime zones will have previously been programmed by your installation company.
A Master level code may change the status of the chime between On and Off. To do
so proceed as follows:-
1) With the display showing U N enter a Master code
2) The display will show S E (flashing)
3) Press NO four times the display will show ( H
4) Press YES, the display will show O F or O N
5) Press NO to change the Chime status.
6) When you have finished press 0 twice to return to the Unset condition.
Programming User Codes
(Master code only)
Please refer to pages 2 & 34 for details of codes already programmed onto your
system.
1) With the display showing U C enter a Master code
2) The display will show S E
3) Press NO five times, the display will show U C (flashing).
4) Press YES, the display will show U -
5) Enter the User number you wish to program (1 to 7 for 800 followed by YES
6) The display will show ( O Enter the required code (4, 5 or 6 digits) followed
by YES. (Entering 000000 will delete an existing code).
7) The display will show t - enter the code type from the following list followed
by YES:-
Code Types may be seen at the beginning of this manual.
PR5075U.qxd 19/06/00 10:59 Page 18

Page 19
GARDTEC
590/591
User Manual
9) If you wish to program other User codes return to step 4
Or
To return to the Unset condition press 0
Programming Date & Time
Note: When using LED keypads the Date & time will only be displayed when the 3
key is pressed whilst viewing the Log.
1) With the display showing U N enter a Master code
2) The display will show S E
3) Press NO six times, the display will show D t (flashing).
4) Press YES, the display will show D - enter the day and month followed by
YES (e.g 0706 for 7th June).
5) The display will show t - enter the time using the 24Hr clock followed by
YES (e.g 2330 for 11:30pm).
6) The display will show D t (flashing).
7) If you wish to re-program the time return to step 4
Or
To return to the Unset condition press 0
User Initiating Remote Access
Users should only initiate Remote Access when instructed to do so by the installation
company.
1) With the display showing U N enter a master level code then press NO
seven times the display will flash A r.
2) Press YES the display will show W X (Wait) then D I (Dialling) then
( N (Connected).
3) When the installation company has finished the display will return to U N
PR5075U.qxd 19/06/00 10:59 Page 19
This manual suits for next models
1
Table of contents
Other GARDINER TECHNOLOGY Control Panel manuals