Contents
User Information......................................................... 2
Using LCD Keypads
Introduction................................................................... 3
User Code Types.......................................................... 3 - 4
Setting The System ...................................................... 5
Unsetting The System .................................................. 6
Part Setting The System............................................... 6 - 7
Area Setting.................................................................. 8
Removing Zones........................................................... 9
Testing The System...................................................... 10
Viewing The Event Log................................................. 11 - 12
Changing The Chime Status......................................... 12 - 13
Programming User Codes ............................................ 13 - 16
Programming Time & Date ........................................... 17
User Initiating Remote Access ..................................... 18
Resetting After An Alarm .............................................. 19 - 20
Using LED Keypads.................................................... 21
Setting The System ...................................................... 21
Unsetting The System .................................................. 21
Part Setting The System............................................... 22
Area Setting.................................................................. 23
Removing Zones........................................................... 23 - 24
Testing The System...................................................... 24
Viewing The Event Log................................................. 25
Changing The Chime Status......................................... 26
Programming User Codes ............................................ 26 - 27
User Initiating Remote Access
Resetting After An Alarm .............................................. 27 - 28
LED Display Glossary................................................... 29 - 30
System Attributes.......................................................... 31 - 33
Service Record ............................................................. 33
User Chart .................................................................... 34
ACE Instructions........................................................... 35
Programming ACE Keyfobs onto your System............. 36
Page 1
GARDTEC
800 Series
User Manual
combi.qxd 12/01/99 09:00 Page 1
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 2
GARDTEC
800 Series
User Manual
User Information
Customer Name:-
Customer Address:-
Control Panel Model
No of Keypads
Keypad 1 Location Type
Keypad 2 Location Type
Keypad 4 Location Type
Keypad 5 Location (840) Type
Keypad 6 Location (840) Type
Keypad 7 Location (840) Type
Keypad 8 Location (840) Type
ACE Mode (if fitted) Normal Security High Security
Keyswitch 1 Location Reserved User Code User No.
Keyswitch 2 Location Reserved User Code User No.
Keyswitch 3 Location Reserved User Code User No.
Keyswitch 4 Location Reserved User Code User No.
Keyswitch 5 Location Reserved User Code User No.
Keyswitch 6 Location Reserved User Code User No.
Keyswitch 7 Location Reserved User Code User No.
Keyswitch 8 Location Reserved User Code User No.
Installation Company Name:-
Installation Company Address:-
Installation Company Tel. Fax.
Other Information:-
Note: Please ensure this section is completed by the installation engineer
Tick Tick Tick
combi.qxd 12/01/99 09:00 Page 2
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 3
GARDTEC
800 Series
User Manual
Introduction
The Gardtec
800 Series
of control panels consists of 3 models, the Gardtec
800
, the
Gardtec
816
and the Gardtec
840
. Two types of display variation are also available,
LCD giving two rows of 16 character English text and LED giving two 7 segment LED
digits.Throughout this manual references will be made to the specific model of
control panel and also the display type. You may find this information from the
user information section on page 2 of this manual.
Please take time to familiarise yourself with the type of equipment fitted to your
premises as it will prove invaluable whilst using this manual.
User Code Types
Four types of User Codes are available on the Gardtec
800,
and six types on the
Gardtec
816,
each user code type allows for different levels of access. In total 7 User
codes may be programmed by a Master Level User Code.
User number 1 will always be a Master Level User but the remaining 6 User Codes
may be programmed (by a Master Code) to the required level of access. These may be
changed at any time via a Master level code
The User Code levels available and the functions available for the levels are:-
1 = Set Only Only Allows for the setting of the system.
2 = Main User Allows Setting, Part Setting, Zone Remove (if programmed
by engineer), System Test, Unsetting, Reset after Alarm (if
programmed by engineer).
3 = User Allows Setting, Part Setting, Reset after Alarm (if
programmed by engineer), Unsetting.
4 = Master Allows Setting, Unsetting, Zone Remove (if programmed by
(User 1 always Master) engineer), Test System, View Log, Chime On/Off, User
Codes, Set Time/Date, Reset After Alarm (if programmed
by engineer), Unsetting.
5 = Cleaner Full System Setting (from unset system),
(816 Only) Cleaner Area Unsetting (from set system),
Cleaner Part Set (from part cleaner set system).
6 = Duress Initiates a Duress call to Central Station whilst appearing
(816 Only) to operate the system as normal.
Note: For information on using Duress on the Gardtec
Series
see Using
Duress Section.
combi.qxd 12/01/99 09:00 Page 3
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 4
GARDTEC
800 Series
User Manual
User Code Types
Ten types of User Codes are available on the Gardtec
840,
and each type allows for
different levels of access. In total 47 User codes may be programmed by a Master
Level User Code to any of the ten types.
User number 1 will always be a Master Level User but the remaining 46 User Codes
may be programmed to the required level of access.
The Code Levels should be viewed as two groups, global codes that give system
control and area codes that give area control.
The User Code levels available and the functions available for the levels are:-
Global Code Levels
0 = Set Only Only Allows for the setting of the system.
1 = Main Allows Setting, Part Setting, Area Setting, Zone Remove,
System Test, Unsetting.
3 = Master Allows Setting, Part Setting, Area Setting, Zone Remove,
System Test, Viewing the Log, Chime On/Off, Program
User Codes, Set Time/Date, Unsetting.
Area Code Levels
2 = Area 1 Allows Area 1 Setting, Area 1 Part Setting, Area 1
Unsetting.
4 = Cleaner Full System Setting (from unset system),
Cleaner Area Unsetting (from set system),
Cleaner Part Set (from part cleaner set system).
5 = Area 2 Allows Area 2 Setting, Area 2 Part Setting, Area 2
Unsetting.
6 = Area 3 Allows Area 3 Setting, Area 3 Part Setting, Area 3
Unsetting.
7 = Main 1 Allows Area 1 Setting, Area 1 Part Setting, Area 1 Zone
Remove, Area 1 Test, Area 1 Unsetting.
8 = Main 2 Allows Area 2 Setting, Area 2 Part Setting, Area 2 Zone
Remove, Area 2 Test, Area 2 Unsetting.
9 = Main 3 Allows Area 3 Setting, Area 3 Part Setting, Area 3 Zone
Remove, Area 3 Test, Area 3 Unsetting.
combi.qxd 12/01/99 09:00 Page 4
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 5
GARDTEC
800 Series
User Manual
Setting The System
1) With the display showing:-
2) Enter the User code (followed by YES if
Master or Main type code has been used).
The display will show:-
and a continuous exit tone will sound
(1 2 3 C may not show on Gardtec
800 & 816)
3) Exit the premises via the authorised exit
route (the exit tone will change if any detectors
are violated during exit)
4) Once the premises are secure listen that the exit
tone returns to the continuous tone.
5) Wait until the exit tone finishes before leaving.
Note: Setting the system with an area code (840 Only) will set only the area
associated with that code.
Note: Setting an unset system with a cleaner code will set the full system.
Setting & Unsetting the
System via a Keyswitch
One of two types of keyswitch(es) may have been fitted to your system.
Normal
To set the system with a normal keyswitch, insert the key and turn to the ON position
then remove the key. To unset insert the key and turn to the OFF position.
Biased
To set the system with a biased keyswitch, insert the key and turn it then return the key
to the original position and remove. To unset repeat this operation.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
EXIT Now ! 1 2 3 C
All Zones ON 15
combi.qxd 12/01/99 09:00 Page 5
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 6
GARDTEC
800 Series
User Manual
Unsetting The System
1) Enter the premises via the authorised entry route
(the broken entry tone will sound),
proceed to the keypad.
2) At the keypad enter a valid code, the display
will show:-
(Area information may be shown on 840)
3) The system is now unset.
Note: If an Area Code (840 Only) has been entered only the area associated
with that code will be unset.
Note: If a Cleaner Code has been entered only the cleaner area will be unset.
Part Setting The System
(using Master & Main type codes)
1) With the display showing:-
2) Enter a Master or Main type code, the
display will show for example:-
(User Name on 816 & 840 Only)
3) Press 1, 2 or 3 (for Part 1, 2 or 3), the
display will show for example:-
(1 2 3 may not show on Gardtec
800 & 816)
Note: (840 Only) If a Global code (Master or Main) has been
used all areas that are being set will be
Part 1 set.
Note: (840 Only) If an Area Main code has been used only
Part 1 set for that associated area will occur.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set , STUART ?
EXIT Now! 1 2 3 C
Part 1 15
combi.qxd 12/01/99 09:00 Page 6
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 7
GARDTEC
800 Series
User Manual
4) The exit tone may or may not be heard
dependant on the system settings.
5) Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop or a single
beep will be emitted (dependant on system
settings).
Part Setting System
(using Area 1, 2 or 3 codes)
1) With the display showing:-
2) Enter an Area Code (1, 2 or 3), the exit
tone will sound and the display
will show for example:-
3) Press NO then 1, 2 or 3 (for the Part Set
you require), the display will show for example:-
4) The exit sounders may or may not go silent
this will depend on the system settings.
5) Exit the premises or retire to an unprotected
part of the system. At the end of the exit time
either the exit sounder will stop or a single
beep will be emitted (dependant on system
settings).
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
EXIT Now ! 1
All Zones ON 15
EXIT Now ! 1
Part 1 20
combi.qxd 12/01/99 09:00 Page 7
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 8
GARDTEC
800 Series
User Manual
Area Setting
(using Master or global Main codes)
Areas will need to have been set up by the installation company.
1) With the display showing:-
2) Enter a Master or global Main code, the
display will show for example:-
3) Press YES to start setting the system,
the exit tone will sound and the display
will show:-
4) To turn Area 1 Off press YES, 1
and / or
To turn Area 2 Off press YES, 2
and / or
To turn Area 3 Off press YES, 3
and / or
To turn the Cleaner Area Off press YES, 0
As areas are turned off they will be removed
from the display.
5) Exit the premises or retire to an un-protected
area (as detectors are violated the continuous
exit tone will change).
Note: Areas must first be programmed by the installation company before
they will appear on the display.
Area Setting (using Area codes)
Area codes are only effective to their own area with the exception of the cleaner area.
This may be turned off by an area code (only if all areas are in the unset condition).
Use is the same as Setting the system shown on page 5 but only the relevant area will
be set
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set. ELIZABETH ?
EXIT Now ! 1 2 3 C
All Zones ON 30
combi.qxd 12/01/99 09:00 Page 8
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 9
GARDTEC
800 Series
User Manual
Removing Zones
(Master & Main codes only)
If programmed by the installation company individual zones may be removed, this may
only be done by a Master or Main level of code. It should be noted that if an Area
Main code is being used, only zones associated with that area may be removed.
1) With the display showing:-
2) Enter a Master or Main level code,
the display will show:-
(User Names on 816 & 840 Only)
3) Press NO, the display will show:-
4) Press YES, the display will show:-
5) Enter the zone number you wish to
remove followed by YES (pressing
NO will 'un-remove' a zone), the
display will show:-
6) Repeat step 5 until you have removed all
the required zones.
7) Press 0 to escape, the display will show:-
8) Press YES, the continuous exit tone will
sound.
9) Exit the premises via the authorised
exit route ( the exit tone will change as detectors
are violated). When the premises are secure
listen that the exit tone returns to the continuous
tone. Wait until the exit tone finishes before leaving.
Note: Zone remove is only effective for the one set.
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Set . STUART ?
Do you want to . .
REMOVE Zones ?
Enter Zone No. - -
then + YES or - NO
Enter Zone No. - -
then + YES or - NO
combi.qxd 12/01/99 09:00 Page 9
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 10
GARDTEC
800 Series
User Manual
Testing The System
(Master & Main codes only)
1) With the display showing:-
2) Enter a Master or Main level code,
the display will show:-
(User Names on 816 & 840 Only)
3) Press NO, the display will show:-
4) Press NO, the display will show:-
5) Press YES, the display will show:-
(This step not applicable on 800 & 816)
6) Press YES to test the full system
or
NO until the area you wish to test is shown
7) Press YES, the display will show:-
for 3 seconds
Then for example:-
8) Pressing 1 will enter zone Status mode (All zones will show on the display
and will be deleted as each zone is triggered). Press 0 to escape.
Pressing 6 will silence the internal sounder,
Pressing 4 will toggle the Strobe On/Off,
Pressing 9 will toggle the Bell On/Off
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
REMOVE Zones ?
Do you want to . .
TEST the System ?
Test ALL Areas ?
1=Status 4 = Strobe
6 = Sounder 9 = Bell
< All Zones OK >
TESTING . . .
combi.qxd 12/01/99 09:00 Page 10
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 11
GARDTEC
800 Series
User Manual
9) Whilst in Test mode any zones violated
will sound the internal sounder (if it has
not been silenced) and show on the
display.
10) When you have finished testing the
system press 0 twice, the display will show:-
Viewing The Event Log
(Master code only)
1) With the display showing:-
2) Enter a Master Code, the display
will show for example:-
(User Names on 816 & 840 Only)
3) Press NO three times, the display
will show:-
4) Press YES, the display will show:-
for 3 seconds
Then, for example:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
View the LOG ?
While Viewing . . .
1 = Printer On / Off
Read Log
01 JAN 18 : 58 : 01
combi.qxd 12/01/99 09:00 Page 11
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 12
GARDTEC
800 Series
User Manual
5) This is the most recent event in the log.
Whilst viewing the Log,
Pressing NO will move back to the previous event.
Pressing YES will move forward to the next event.
Pressing 7 will take you to back to the last event of
the previous day.
Pressing 9 will take you forward to the first event of
the next day.
6) When you have finished viewing the Log press 0 twice
the display will show:-
Changing The Chime Status
(Master code only)
The Chime zones will have previously been programmed by the installation company.
A Master level code may change the status of the Chime between On and Off. To do
so proceed as follows:-
1) With the display showing:-
2) Enter a Master Code, the display will
show for example:-
(User Names on 816 & 840 Only)
3) Press NO four times, the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Change Chime ?
combi.qxd 12/01/99 09:00 Page 12
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 13
GARDTEC
800 Series
User Manual
4) Press YES the display will show for example:-
Or:-
5) Press NO to change the status of the Chime,
then press YES, the display will show:-
6) Press 0 to escape, the display will show:-
Chime is Off ok ?
Chime is On ok ?
Do you want to . .
Change Chime ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
combi.qxd 12/01/99 09:00 Page 13
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 14
GARDTEC
800 Series
User Manual
Programming User Codes
(Master code only)
The charts on pages 2 & 34 should be completed by the engineer/user for future
reference of what codes have been allocated on your system. Under no
circumstances should the actual user code be written down.
If your installation company has given you keyswitches for the operation of your
system the last five user codes may have been reserved for use by these keyswitches.
If your engineer has indicated (see pages 2 & 34) that some
of the user numbers on your system have been reserved you
should not use them whilst programming user codes. If you
do so your system may be adversely affected
1) With the display showing:-
2) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
3) Press NO five times, the display will show:-
4) Press YES, the display will show:-
(1 - 7) displayed on 800 & 816
5) Enter the user number (1 to 47 for 840 or
1 to 7 for 800/816) that you
wish to program followed by YES, the
display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Prog. USER CODES ?
Enter User No. - -
(1- 47) Then YES
Now Enter Code . .
- - - - - - Then YES
combi.qxd 12/01/99 09:00 Page 14
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 15
GARDTEC
800 Series
User Manual
6) Enter the code you require (codes may be 4,
5 or 6 digits) followed by YES.
(Entering 000000 will delete an existing code)
Note: If the code already exists or is a duress of
another code an error will be shown,
choose another code and return to step 6
7) The display will show:-
(not if user 1 is being programmed).
The display will scroll showing the code
types available (see user types or display).
8) Enter the required type followed by YES,
the display will show for example:-
(816 & 840 Only)
9) If you wish to accept the name shown press
YES and jump to step 13
Or
If you wish to change the name shown press
NO, the display will show:-
10) You may now enter up to nine characters for
the user name using the layout shown below
for the allocation of characters.
User 1 Name
= STUART
User 1 Name
>
123
456
789
0 YESNO
ABC DEF GHI
JKL MNO PQR
STU VWX YZ
0-9
Choose Type . . -
0 = xxxxxx 1 = xxxxxx
combi.qxd 12/01/99 09:00 Page 15
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 16
GARDTEC
800 Series
User Manual
11) Referring to the character map enter the required
character (pressing the 3 key will display 'G', pressing
it again will show 'H' and again will show 'I '), once
the correct character is displayed press YES and the
display will move on to the next position.
12) Continue entering characters (up to 9). If
you require a blank space press YES while
the '-' is displayed
13) As you press YES for the ninth character
(or if you have jumped from step 9) the
display will change to:-
14) If you wish to program other User Codes
return to step 4
Or
Press 0 to return to:-
Do you want to . .
Prog. USER CODES ?
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
combi.qxd 12/01/99 09:00 Page 16
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 17
GARDTEC
800 Series
User Manual
Programming Time & Date
1) With the display showing:-
2) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
3) Press NO six times, the display will show:-
4) Press YES the display will show:-
5) Enter the Day/Month (ie. 0706 for 7th June)
followed by YES. The display will show:-
6) Enter the time using 24Hr Clock (ie. 23:30 for
11:30pm) followed by YES the display will show:-
7) Press 0 the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Set DATE / TIME ?
Enter Day / Month
-- -- / -- -- Then YES
Enter Hrs / Mins
-- -- : -- -- Then YES
Do you want to . .
Set DATE / TIME ?
< < < < UN-SET > > > >
07 Jun 23: 30: 02
combi.qxd 12/01/99 09:00 Page 17
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 18
GARDTEC
800 Series
User Manual
User Initiating Remote Access (Optional)
Access Remote allows your installation company to examine your system and re-
program system settings as you need the changes without the need for an engineer to
visit your premises.
If your system has remote communications fitted your installation company may have
programmed the system so that you initialise the Access Remote call (usually on lines
with incoming calls barred).
To initiate the Remote Call follow the instructions below.
1) Negotiate with your installation company when you should
initiate the Remote Call.
2) With the display showing:-
3) Enter a Master Code, the display will show:-
(User Names on 816 & 840 Only)
4) Press NO seven times, the display will show:-
5) Press YES the display will show:-
Until Dialling commences
Then:-
Until Connection
Then:-
6) When your installation company has finished
the display will show:-
Note: In the event of any errors the display will show:-
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
Do you want to . .
Set . STUART ?
Do you want to . .
Access Remote ?
Please WAIT
Please WAIT
Dialling
Please WAIT
Connect
< < < < UN-SET > > > >
01 JAN 18 : 58 : 01
! ! ! ! ERROR ! ! ! !
Try Again . . . .
combi.qxd 12/01/99 09:00 Page 18
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com

Page 19
GARDTEC
800 Series
User Manual
Resetting After an Alarm
Your installation company will have programmed the reset modes for your system so
that it complies to your insurance company and legislation requirements.
Your installation company will have informed you as to the type of reset that your
system is set for.
Before attempting to reset your system ensure that the system is Un-set.
1) If the system is programmed for any code reset
enter a user (followed by YES if Master or Main
code is used), the exit tone will sound and the
display will show for example:-
(1 2 3 may not show on Gardtec
800 & 816)
2) Enter the code again to abort the setting
3) The system is now reset
Or
If a higher level of code is required one of
the following displays will be shown:-
Use a Master code to reset the system.
Or:-
Call the installation company
Or:-
Call the installation company and quote
the number given
Or:-
Can't Set Use
Master Code
Can't Set Use
ENGNR Code
Can't Set Use
ENG +Anti Code 1234
Can't Set Use
Anti Code 1234
EXIT Now ! 1 2 3 C
All Zones ON 15
combi.qxd 12/01/99 09:00 Page 19
Technical Manuals Online! - http://www.tech-man.comTechnical Manuals Online! - http://www.tech-man.com
Other manuals for Gardtec 800
1
This manual suits for next models
2
Table of contents